Temperature of maximal cavitation intensity of glycol ethers in ultrasonic cleaning

被引:0
作者
Niemczewski, B [1 ]
机构
[1] Tele & Radio Res Inst, PL-03450 Warsaw, Poland
来源
TRANSACTIONS OF THE INSTITUTE OF METAL FINISHING | 2004年 / 82卷
关键词
cavitation; ultrasonic cleaning; glycol ethers;
D O I
10.1080/00202967.2004.11871557
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ultrasonic cavitation intension in six glycol ethers (and as reference - in tetrachloroethylene) was measured in two ultrasonic cleaners of different rated power and operating at about 40 kHz. Cavitation was measured in ca. 20 dm(3) volumes of liquid at 8 different levels, every 4 mm. For each liquid the temperature of maximal cavitation intensity was looked for It was found out that not only the cavitation intensity but also the temperature of maximal cavitation in glycol ethers depend to a high degree on the level of liquid.