Oxidized zirconium femoral component for TKA: A follow-up note of a previous report at a minimum of 10 years

被引:26
作者
Innocenti, Massimo [1 ]
Matassi, Fabrizio [1 ]
Carulli, Christian [1 ]
Nistri, Lorenzo [1 ]
Civinini, Roberto [1 ]
机构
[1] Univ Florence, Orthoped Clin, Dept Special Surg Sci, I-50139 Florence, Italy
关键词
Oxidized zirconium; Total knee arthroplasty; Femoral component; TOTAL KNEE ARTHROPLASTY; COBALT-CHROMIUM; POLYETHYLENE WEAR; SURVIVAL ANALYSIS; 10-YEAR; SYSTEM; REPLACEMENT; PERFORMANCE;
D O I
10.1016/j.knee.2014.04.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: New bearing surfaces for total knee replacement have been described in an attempt to reduce polyethylene wear and secondary osteolysis and improve longevity of implants. Oxidized zirconium is a new material that combines the strength of a metal with the wear properties of a ceramic. However, there are no reports as to who documents the long term results. We report a 10 year follow-up note of a selected series of TKAs with an oxidized zirconium femoral component. Methods: We prospectively follow 98 TKAs performed in 94 patients with an oxidized zirconium femoral component. Five patients (5 knees) had died and 6 (6 knees) were lost to follow-up at a minimum of 2 years (mean, 6.3 years; range, 2-9 years) after the operation. For the remaining 83 patients (87 knees), the minimum follow-up was 10 years (mean, 11.3 years; range, 10.0-12.6 years). In 51 cases (58.6%), a cruciate-retaining implant with a deep-dished, more conforming PE was used, and in 36 cases (41.4%), a posterior-stabilized design was used. The patellae were resurfaced in 32 cases (36.7%) and in 55 cases (63.3%) were left unresurfaced. Results: Survivorship was 97.8% at 10 years postoperatively. Two knees were revised for aseptic loosening of the femoral component. No major complication was observed clinically or radiologically. Mean Knee Society score improved from 36 to 84 and functional score from 37 to 83. Conclusions: Oxidized zirconium femoral component in TKA performs well over the first 10 years following implantation, with excellent survival rates and good clinical and radiological outcomes. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:858 / 861
页数:4
相关论文
共 29 条
  • [1] Survival analysis of total knee arthroplasty at a minimum 10 years' follow-up: A multicenter French nationwide study including 846 cases
    Argenson, J. -N.
    Boisgard, S.
    Parratte, S.
    Descamps, S.
    Bercovy, M.
    Bonnevialle, P.
    Briard, J. -L.
    Brilhault, J.
    Chouteau, J.
    Nizard, R.
    Saragaglia, D.
    Servien, E.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (04) : 385 - 390
  • [2] Survivorship analysis at 15 years of cemented press-fit condylar total knee arthroplasty
    Attar, Fahad G.
    Khaw, Fli-Meng
    Kirk, Lorna M. G.
    Gregg, P. J.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (03) : 344 - 349
  • [3] Contemporary Cruciate-Retaining Total Knee Arthroplasty with a Pegged Tibial Baseplate Results at a Minimum of Ten Years
    Barrington, John W.
    Sah, Alexander
    Malchau, Henrik
    Burke, Dennis W.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (04) : 874 - 878
  • [4] Bourne RB, 2007, ORTHOPEDICS, V30, P83
  • [5] Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium
    Brandt, J. -M.
    Guenther, L.
    O'Brien, S.
    Vecherya, A.
    Turgeon, T. R.
    Bohm, E. R.
    [J]. KNEE, 2013, 20 (06) : 388 - 396
  • [6] Carulli Christian, 2012, J Long Term Eff Med Implants, V22, P305
  • [7] Modular fixed-bearing total knee arthroplasty with retention of the posterior cruciate ligament - A study of patients followed for a minimum of fifteen years
    Dixon, MC
    Brown, RR
    Parsch, D
    Scott, RD
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (03) : 598 - 603
  • [8] EWALD FC, 1989, CLIN ORTHOP RELAT R, P9
  • [9] Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    Ezzet, KA
    Hermida, JC
    Colwell, CW
    D'Lima, DD
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 120 - 124
  • [10] Wear of Polyethylene Against Oxidized Zirconium Femoral Components Effect of Aggressive Kinematic Conditions and Malalignment in Total Knee Arthroplasty
    Ezzet, Kace A.
    Hermida, Juan C.
    Steklov, Nikolai
    D'Lima, Darryl D.
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (01) : 116 - 121