A review on the reliability of hemodynamic modeling in intracranial aneurysms: why computational fluid dynamics alone cannot solve the equation

被引:76
作者
Berg, Philipp [1 ,2 ]
Saalfeld, Sylvia [2 ,3 ]
Voss, Samuel [1 ,2 ]
Beuing, Oliver [2 ,4 ]
Janiga, Gabor [1 ,2 ]
机构
[1] Univ Magdeburg, Dept Fluid Dynam & Tech Flows, Magdeburg, Germany
[2] Univ Magdeburg, Res Campus Stimulate, Magdeburg, Germany
[3] Univ Magdeburg, Dept Simulat & Graph, Magdeburg, Germany
[4] Univ Hosp Magdeburg, Dept Neuroradiol, Magdeburg, Germany
关键词
computational fluid dynamics; intracranial aneurysms; imaging; segmentation; uncertainty quantification; BLOOD-FLOW SIMULATIONS; CEREBRAL ANEURYSMS; RUPTURE STATUS; WAVE-FORMS; IMPACT; ARTERY; RISK; SENSITIVITY; ANGIOGRAPHY; PREDICTION;
D O I
10.3171/2019.4.FOCUS19181
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Computational blood flow modeling in intracranial aneurysms (IAs) has enormous potential for the assessment of highly resolved hemodynamics and derived wall stresses. This results in an improved knowledge in important research fields, such as rupture risk assessment and treatment optimization. However, due to the requirement of assumptions and simplifications, its applicability in a clinical context remains limited. This review article focuses on the main aspects along the interdisciplinary modeling chain and highlights the circumstance that computational fluid dynamics (CFD) simulations are embedded in a multiprocess workflow. These aspects include imaging-related steps, the setup of realistic hemodynamic simulations, and the analysis of multidimensional computational results. To condense the broad knowledge, specific recommendations are provided at the end of each subsection. Overall, various individual substudies exist in the literature that have evaluated relevant technical aspects. In this regard, the importance of precise vessel segmentations for the simulation outcome is emphasized. Furthermore, the accuracy of the computational model strongly depends on the specific research question. Additionally, standardization in the context of flow analysis is required to enable an objective comparison of research findings and to avoid confusion within the medical community. Finally, uncertainty quantification and validation studies should always accompany numerical investigations. In conclusion, this review aims for an improved awareness among physicians regarding potential sources of error in hemodynamic modeling for IAs. Although CFD is a powerful methodology, it cannot provide reliable information, if pre- and postsimulation steps are inaccurately carried out. From this, future studies can be critically evaluated and real benefits can be differentiated from results that have been acquired based on technically inaccurate procedures.
引用
收藏
页数:9
相关论文
共 75 条
[1]   Minimizing the blood velocity differences between phase-contrast magnetic resonance imaging and computational fluid dynamics simulation in cerebral arteries and aneurysms [J].
Adib, Mohd Azrul Hisham Mohd ;
Ii, Satoshi ;
Watanabe, Yoshiyuki ;
Wada, Shigeo .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (09) :1605-1619
[2]  
[Anonymous], 2016, Neurovasc Imaging, DOI DOI 10.1186/S40809-016-0016-3
[3]   Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression [J].
Bakhshinejad, Ali ;
Baghaie, Ahmadreza ;
Vali, Alireza ;
Saloner, David ;
Rayz, Vitaliy L. ;
D'Souza, Roshan M. .
JOURNAL OF BIOMECHANICS, 2017, 58 :162-173
[4]   Explorative Blood Flow Visualization using Dynamic Line Filtering based on Surface Features [J].
Behrendt, B. ;
Berg, P. ;
Beuing, O. ;
Preim, B. ;
Saalfeld, S. .
COMPUTER GRAPHICS FORUM, 2018, 37 (03) :183-194
[5]   Does the DSA reconstruction kernel affect hemodynamic predictions in intracranial aneurysms? An analysis of geometry and blood flow variations [J].
Berg, P. ;
Saalfeld, S. ;
Voss, S. ;
Redel, T. ;
Preim, B. ;
Janiga, G. ;
Beuing, O. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (03) :290-296
[6]   Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH): Phase I: Segmentation [J].
Berg, Philipp ;
Voss, Samuel ;
Saalfeld, Sylvia ;
Janiga, Gabor ;
Bergersen, Aslak W. ;
Valen-Sendstad, Kristian ;
Bruening, Jan ;
Goubergrits, Leonid ;
Spuler, Andreas ;
Cancelliere, Nicole M. ;
Steinman, David A. ;
Pereira, Vitor M. ;
Chiu, Tin Lok ;
Tsang, Anderson Chun On ;
Chung, Bong Jae ;
Cebral, Juan R. ;
Cito, Salvatore ;
Pallares, Jordi ;
Copelli, Gabriele ;
Csippa, Benjamin ;
Paal, Gyorgy ;
Fujimura, Soichiro ;
Takao, Hiroyuki ;
Hodis, Simona ;
Hille, Georg ;
Karmonik, Christof ;
Elias, Saba ;
Kellermann, Kerstin ;
Khan, Muhammad Owais ;
Marsden, Alison L. ;
Morales, Hernan G. ;
Piskin, Senol ;
Finol, Ender A. ;
Pravdivtseva, Mariya ;
Rajabzadeh-Oghaz, Hamidreza ;
Paliwal, Nikhil ;
Meng, Hui ;
Seshadhri, Santhosh ;
Howard, Matthew ;
Shojima, Masaaki ;
Sugiyama, Shin-ichiro ;
Niizuma, Kuniyasu ;
Sindeev, Sergey ;
Frolov, Sergey ;
Wagner, Thomas ;
Brawanski, Alexander ;
Qian, Yi ;
Wu, Yu-An ;
Carlson, Kent D. ;
Dragomir-Daescu, Dan .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) :565-581
[7]   The Computational Fluid Dynamics Rupture Challenge 2013-Phase II: Variability of Hemodynamic Simulations in Two Intracranial Aneurysms [J].
Berg, Philipp ;
Roloff, Christoph ;
Beuing, Oliver ;
Voss, Samuel ;
Sugiyama, Shin-Ichiro ;
Aristokleous, Nicolas ;
Anayiotos, Andreas S. ;
Ashton, Neil ;
Revell, Alistair ;
Bressloff, Neil W. ;
Brown, Alistair G. ;
Chung, Bong Jae ;
Cebral, Juan R. ;
Copelli, Gabriele ;
Fu, Wenyu ;
Qiao, Aike ;
Geers, Arjan J. ;
Hodis, Simona ;
Dragomir-Daescu, Dan ;
Nordahl, Emily ;
Suzen, Yildirim Bora ;
Khan, Muhammad Owais ;
Valen-Sendstad, Kristian ;
Kono, Kenichi ;
Menon, Prahlad G. ;
Albal, Priti G. ;
Mierka, Otto ;
Muenster, Raphael ;
Morales, Hernan G. ;
Bonnefous, Odile ;
Osman, Jan ;
Goubergrits, Leonid ;
Pallares, Jordi ;
Cito, Salvatore ;
Passalacqua, Alberto ;
Piskin, Senol ;
Pekkan, Kerem ;
Ramalho, Susana ;
Marques, Nelson ;
Sanchi, Stephane ;
Schumacher, Kristopher R. ;
Sturgeon, Jess ;
Svihlova, Helena ;
Hron, Jaroslav ;
Usera, Gabriel ;
Mendina, Mariana ;
Xiang, Jianping ;
Meng, Hui ;
Steinman, David A. ;
Janiga, Gabor .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (12)
[8]   Cerebral Blood Flow in a Healthy Circle of Willis and Two Intracranial Aneurysms: Computational Fluid Dynamics Versus Four-Dimensional Phase-Contrast Magnetic Resonance Imaging [J].
Berg, Philipp ;
Stucht, Daniel ;
Janiga, Gabor ;
Beuing, Oliver ;
Speck, Oliver ;
Thevenin, Dominique .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (04)
[9]   Modeling hemodynamics in intracranial aneurysms: Comparing accuracy of CFD solvers based on finite element and finite volume schemes [J].
Botti, Lorenzo ;
Paliwal, Nikhil ;
Conti, Pierangelo ;
Antiga, Luca ;
Meng, Hui .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (09)
[10]   Unruptured intracranial aneurysms: epidemiology, natural history, management options, and familial screening [J].
Brown, Robert D., Jr. ;
Broderick, Jrioseph P. .
LANCET NEUROLOGY, 2014, 13 (04) :393-404