摘要
Purpose: Arterial spin labeling can be used to assess the transition time of water molecules across the blood-brain barrier when combined with sequence modules, which allow a separation of intravascular from tissue signal. The bipolar gradient technique measures the intravascular fraction by removing flowing spins. The T-2 -relaxation-under-spin-tagging (TRUST) technique modulates the TE to differentiate between intravascular and extravascular spins based on T-2. These modules were combined into a single time-encoded pseudo-continuous arterial spin labeling sequence to compare their mechanisms of action as well as their assessment of water transition across the blood-brain barrier. Methods: This protocol was acquired on a scanner with 9 healthy volunteers who provided written, informed consent. The sequence consisted of a Hadamard-encoded pseudo-continuous arterial spin labeling module, followed by the TRUST module (effective TEs of 0, 40, and 80 ms) and bipolar flow-crushing gradients (2, 4, and infinity cm/s). An additional experiment was performed with TRUST and a 3D gradient and spin-echo readout. Results: Gradients imperfectly canceled the intravascular signal, as evidenced by the presence of residual signal in the arteries at early postlabeling delays as well as the underestimation of the intravascular fraction as compared with the TRUST method. The TRUST module allowed us to detect the transport of water deeper into the vascular tree through changes in T-2 than the used crusher gradients could, with their limited b-value. Conclusion: Of the implemented techniques, TRUST allowed us to follow intravascular signal deeper into the vascular tree than the approach with (relatively weak) crusher gradients when quantifying the transport time of water across the blood-brain barrier.
引用
收藏
页码:2649 / 2660
页数:12
相关论文
共 37 条
  • [1] Recommended Implementation of Arterial Spin-Labeled Perfusion MRI for Clinical Applications: A Consensus of the ISMRM Perfusion Study Group and the European Consortium for ASL in Dementia
    Alsop, David C.
    Detre, John A.
    Golay, Xavier
    Guenther, Matthias
    Hendrikse, Jeroen
    Hernandez-Garcia, Luis
    Lu, Hanzhang
    MacIntosh, Bradley J.
    Parkes, Laura M.
    Smits, Marion
    van Osch, Matthias J. P.
    Wang, Danny J. J.
    Wong, Eric C.
    Zaharchuk, Greg
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (01) : 102 - 116
  • [2] Measurement of vascular water transport in human subjects using time-resolved pulsed arterial spin labelling
    Bibic, Adnan
    Knutsson, Linda
    Schmidt, Anders
    Henningsson, Erik
    Mansson, Sven
    Abul-Kasim, Kasim
    Akeson, Jonas
    Gunther, Matthias
    Stahlberg, Freddy
    Wirestam, Ronnie
    [J]. NMR IN BIOMEDICINE, 2015, 28 (08) : 1059 - 1068
  • [3] Brown RW, 2014, Magnetic resonance imaging: Physical principles and sequence design, V2nd
  • [4] A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    Buxton, RB
    Frank, LR
    Wong, EC
    Siewert, B
    Warach, S
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) : 383 - 396
  • [5] What levels of precision are achievable for quantification of perfusion and capillary permeability surface area product using ASL?
    Carr, John P.
    Buckley, David L.
    Tessier, Jean
    Parker, Geoff J. M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (02) : 281 - 289
  • [6] Human Whole Blood T2 Relaxometry at 3 Tesla
    Chen, Jean J.
    Pike, G. Bruce
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (02) : 249 - 254
  • [7] Comparison of arterial transit times estimated using arterial spin labeling
    Chen, Yufen
    Wang, Danny J. J.
    Detre, John A.
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2012, 25 (02) : 135 - 144
  • [8] Variability of physiological brain perfusion in healthy subjects - A systematic review of modifiers. Considerations for multi-center ASL studies
    Clement, Patricia
    Mutsaerts, Henk-Jan
    Vaclavu, Lena
    Ghariq, Eidrees
    Pizzini, Francesca B.
    Smits, Marion
    Acou, Marjan
    Jovicich, Jorge
    Vanninen, Ritva
    Kononen, Mervi
    Wiest, Roland
    Rostrup, Egill
    Bastos-Leite, Antonio J.
    Larsson, Elna-Marie
    Achten, Eric
    [J]. JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2018, 38 (09) : 1418 - 1437
  • [9] Gonzalez-At JB, 2000, MAGNET RESON MED, V43, P739, DOI 10.1002/(SICI)1522-2594(200005)43:5<739::AID-MRM17>3.0.CO
  • [10] 2-2