Quantitative gait analysis after total hip arthroplasty through a minimally invasive direct anterior approach: A case control study

被引:8
|
作者
Martinez, Lucas [1 ,2 ]
Noe, Nathalie [1 ]
Beldame, Julien [3 ]
Matsoukis, Jean [4 ]
Poirier, Thomas [1 ]
Brunel, Helena [1 ]
Van Driessche, Stephane [5 ]
Lalevee, Matthieu [1 ,6 ]
Billuart, Fabien [1 ,2 ]
机构
[1] Lab Anal Mouvement Inst Format Masso Kinesithera, 68 Rue Commerce, F-75015 Paris, France
[2] UVSQ, Unite Rech ERPHAN, UR 20201, Versailles, France
[3] Clin Meg, 1328 Ave Maison Blanche, F-76550 St Aubin Sur Scie, France
[4] Grp Hosp Havre, Dept Chirurg Orthoped, BP24, F-76083 Le Havre, France
[5] Clin Montargis, 46 Rue Quintaine, F-45200 Montargis, France
[6] Ctr Hosp Univ Rouen, Serv Chirurg Orthoped & Traumatol, F-76000 Rouen, France
关键词
Total hip arthroplasty; Minimally invasive anterior approach; Quantitative gait analysis; Electromyography; SURGICAL APPROACH; LATERAL APPROACH; PARAMETERS; POSTERIOR; MECHANICS; PATTERNS; LENGTH;
D O I
10.1016/j.otsr.2022.103214
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Total Hip Arthroplasty (THA) leads to excellent clinical and functional results. The Minimally Invasive Anterior Approach (MIAA) theoretically allows rapid recovery and a reduction in the need for rehabilitation, but alterations in muscle and static balance have previously been demonstrated. Kinetic, kinematic and muscular alterations have been shown to persist up to 1 year postoperatively but data beyond 1 year postoperatively is lacking. Thus, the objective of this study was to compare the data from Quantitative Gait Analysis (QGA) coupled with electromyography (EMG), of patients one year postoperatively with THA through MIAA, compared to an asymptomatic control group. Hypothesis: We hypothesized that QGA and EMG parameters would not normalize beyond one year postoperatively. Patients and Methods: Twenty-seven patients were recruited, including 15 subjects (64.6 +/- 6.6 years) operated on by MIAA, who at 15.9 +/- 3.1 months postoperatively, along with 12 asymptomatic control subjects (68.9 +/- 9.7 years), who underwent QGA and maximal isometric muscle strength tests, coupled with EMG on the gluteus medius and maximus, Tensor Fascia Lata (TFL) and Sartorius muscles. The spatiotemporal parameters of walking (step length, walking speed, cadence, single leg support time), kinetics (vertical ground reaction forces, hip moments in the 3 planes) and kinematics (coxofemoral and pelvic amplitudes) were analyzed. Results: The walking speed was lower on the non-operated side of the experimental subjects (0.96ms-1 compared to 1.13ms-1 for asymptomatic [p= 0.018]), as was the step length on the operated side (0.53 m compared to 0.60m for asymptomatic [p = 0.042]). Maximal isometric muscle strength was lower in subjects operated on for the gluteus maximus and medius (p=0.004), compared to asymptomatic subjects. Moments were lower in the subjects operated on in extension (0.72 Nm on the operated side, 0.75 Nm on the non-operated side compared to 1.06 Nm for asymptomatic [p = 0.007 and p= 0.024]) and lateral rotation (0.09 Nm on the operated side, 0.05 Nm on the non-operated side compared to 0.16 Nm for asymptomatic subjects [p=0.009 and p= 0.0005]). Hip adduction amplitudes were lower on the operated side compared to asymptomatic subjects (3.93 degrees versus 9.14 degrees for asymptomatic [p = 0.005]). Pelvic amplitudes in the frontal plane were lower amongst operated subjects (0.44 degrees against 1.97 degrees for asymptomatic [p=0.041]). Pelvic amplitudes in the sagittal plane were higher in the operated subjects (15.74 degrees on the operated side, 15.43 degrees on the non-operated side compared to 9.65 degrees for asymptomatic [p= 0.041 and p= 0.032]). Discussion: Our initial hypothesis was validated, since walking deficits persisted beyond one year post-operatively after THA through MIAA. A decrease in maximal isometric muscle strength of the gluteus medius and gluteus maximus was observed, as well as an alteration of kinetic and kinematic parameters in the sagittal and frontal planes. The results were in agreement with the literature and reflected the establishment of compensatory mechanisms to overcome alterations in joint strength and range more than one year postoperatively. These results would allow rehabilitation programs to be more specific and would justify a study on the other approaches for THA. (C) 2022 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] The effect of conjoint tendon release on gait after direct anterior total hip arthroplasty
    Zomar, Bryn O.
    Bryant, Dianne
    Hunter, Susan
    Howard, James L.
    Lanting, Brent A.
    HIP INTERNATIONAL, 2019, 29 (06) : 578 - 583
  • [32] The minimal invasive direct anterior approach in combination with large heads in total hip arthroplasty - is dislocation still a major issue? a case control study
    Hoell, Steffen
    Sander, Marius
    Gosheger, Georg
    Ahrens, Helmut
    Dieckmann, Ralf
    Hauschild, Gregor
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [33] The minimal invasive direct anterior approach in combination with large heads in total hip arthroplasty - is dislocation still a major issue? a case control study
    Steffen Hoell
    Marius Sander
    Georg Gosheger
    Helmut Ahrens
    Ralf Dieckmann
    Gregor Hauschild
    BMC Musculoskeletal Disorders, 15
  • [34] Digital templating cementless short stem total hip arthroplasty: is there a difference in planning adherence between the direct anterior approach and minimally invasive anterolateral approach?
    Luger, Matthias
    Feldler, Sandra
    Schauer, Bernhard
    Hochgatterer, Rainer
    Gotterbarm, Tobias
    Klasan, Antonio
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (03) : 1619 - 1626
  • [35] Comparison of Gait in Patients Following a Computer-Navigated Minimally Invasive Anterior Approach and a Conventional Posterolateral Approach for Total Hip Arthroplasty: A Randomized Controlled Trial
    Reininga, Inge H. F.
    Stevens, Martin
    Wagenmakers, Robert
    Boerboom, Alexander L.
    Groothoff, Johan W.
    Bulstra, Sjoerd K.
    Zijlstra, Wiebren
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (02) : 288 - 294
  • [36] Minimally invasive anterolateral approach versus direct anterior approach total hip arthroplasty in the supine position: a prospective study based on early postoperative outcomes
    Hongwen Liu
    Li Yin
    Jiao Li
    Shaojiang Liu
    Qifeng Tao
    Jie Xu
    Journal of Orthopaedic Surgery and Research, 17
  • [37] Anterior-Supine Minimally Invasive Total Hip Arthroplasty: Defining the Learning Curve
    Seng, Brian E.
    Berend, Keith R.
    Ajluni, Andrew F.
    Lombardi, Adolph V., Jr.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2009, 40 (03) : 343 - +
  • [38] Nerve injuries in total hip arthroplasty with a mini invasive anterior approach
    Macheras, George A.
    Christofilopoulos, Panayiotis
    Lepetsos, Panagiotis
    Leonidou, Andreas O.
    Anastasopoulos, Panagiotis P.
    Galanakos, Spyridon P.
    HIP INTERNATIONAL, 2016, 26 (04) : 338 - 343
  • [39] Total hip arthroplasty through the direct anterior approach in morbidly obese patients
    Argyrou, C.
    Tzefronis, D.
    Sarantis, M.
    Kateros, K.
    Poultsides, L.
    Macheras, G. A.
    BONE & JOINT OPEN, 2022, 3 (01): : 4 - 11
  • [40] Modified anterolateral approach in minimally invasive total hip arthroplasty
    Tsai, Shang-Wen
    Chen, Cheng-Fong
    Wu, Po-Kuei
    Chen, Tain-Hsiung
    Liu, Chien-Lin
    Chen, Wei-Ming
    HIP INTERNATIONAL, 2015, 25 (03) : 245 - 250