LC-MS/MS assay for the quantitation of FdCyd and its metabolites FdUrd and FU in human plasma

被引:9
|
作者
Holleran, Julianne L. [1 ]
Eiseman, Julie L. [1 ,2 ]
Parise, Robert A. [1 ,3 ]
Kummar, Shivaani [4 ]
Beumer, Jan H. [1 ,3 ,5 ]
机构
[1] Univ Pittsburgh, Inst Canc, Canc Therapeut Drug Discovery Program, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Med, Dept Pharmacol & Chem Biol, Pittsburgh, PA USA
[3] Univ Pittsburgh, Sch Pharm, Dept Pharmaceut Sci, Pittsburgh, PA 15261 USA
[4] NCI, Div Canc Treatment & Diag, Bethesda, MD 20892 USA
[5] Univ Pittsburgh, Sch Med, Dept Med, Div Hematol Oncol, Pittsburgh, PA 15213 USA
关键词
FdCyd; Tandem mass spectrometry; Metabolites; Assay; Validation; METHYLTRANSFERASE INHIBITOR 5-FLUORO-2'-DEOXYCYTIDINE; TETRAHYDROURIDINE; 5-FLUORO-2-DEOXYCYTIDINE; MICE; PHARMACOKINETICS; THU;
D O I
10.1016/j.jpba.2016.07.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The hypomethylating agent 5-fluoro-2'-deoxycytidine (FdCyd, NSC 48006) is being evaluated clinically both via the intravenous route and via the oral route in combination with 3,4,5,6-tetrahydrouridine (THU), a potent inhibitor of FdCyd catabolism. To determine the pharmacokinetics of FdCyd and downstream metabolites, we developed and validated an LC-MS/MS assay for the quantitation of FdCyd, 5-fluoro-2'-deoxyuridine (FdUrd), and 5-fluorouracil (FU) in 0.2 mL human plasma. After acetonitrile protein precipitation, the sample was split and separate chromatography was achieved for FdCyd with a Synergi Polar-RP column and for FdUrd and FU with a Shodex Asahipak NH2P-50 2D column. Gradients of 0.1% acetic acid in acetonitrile and water were used. Detection with a Quattromicro quadrupole mass spectrometer with electrospray ionization in positive-ion (FdCyd) or negative-ion (FdUrd and FU) multiple reaction monitoring (MRM) mode. The assay was linear from 5 to 3000 ng/mL for all three analytes and proved to be accurate (96.7-105.5%) and precise (<8.1%CV), and fulfilled FDA criteria for bioanalytical method validation. We demonstrated the suitability of this assay for measuring FdCyd and metabolites FdUrd and FU in plasma from a patient who was administered 120 mg PO FdCyd 30 min after 3000 mg THU. Our LC-MS/MS assay will be an essential tool to further define the pharmacology of FdCyd in ongoing and future studies. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:359 / 366
页数:8
相关论文
共 50 条
  • [1] Development and validation of a sensitive LC-MS/MS assay for simultaneous quantitation of ranolazine and its three metabolites in human plasma
    Wang, Yuan
    Chen, Xiaoyan
    Sun, Zuoming
    Yang, Yong
    Zhang, Ying
    Liu, Wanhui
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 889 : 10 - 16
  • [2] LC-MS/MS assay for the quantitation of the HDAC inhibitor belinostat and five major metabolites in human plasma
    Kiesel, Brian F.
    Parise, Robert A.
    Tjornelund, Jette
    Christensen, Mette K.
    Loza, Einars
    Tawbi, Hussein
    Chu, Edward
    Kummar, Shivaani
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 81-82 : 89 - 98
  • [3] LC-MS/MS quantitation of antimalarial drug piperaquine and metabolites in human plasma
    Aziz, Mohd Yusmaidie
    Hoffmann, Kurt-Jurgen
    Ashton, Michael
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1063 : 253 - 258
  • [4] Sensitive and selective LC-MS/MS assay for quantitation of flutrimazole in human plasma
    Shen, L.
    Liu, S. -J.
    Zhang, N. -S.
    Dai, G. -L.
    Zou, C.
    Li, C. -Y.
    Chen, X. -H.
    Ju, W. -Z.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2017, 21 (12) : 2964 - 2969
  • [5] Quantitation of Cabozantinib in Human Plasma by LC-MS/MS
    Jones, Reyna
    Holleran, Julianne
    Parise, Robert A.
    Rudek, Michelle A.
    Chan, Jennifer
    Wen, Yujia
    Gobburu, Joga
    Lewis, Lionel D.
    Beumer, Jan H.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2022, 60 (03) : 274 - 279
  • [6] Quantitation and Abundance of Xylazine and Xylazine Metabolites in Human Urine and Plasma by LC-MS/MS
    Lin, Yanchun
    Farnsworth, Christopher
    Crews, Bridgit
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2024, 162 : S161 - S161
  • [7] LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma
    Kiesel, Brian F.
    Parise, Robert A.
    Wong, Alvin
    Keyvanjah, Kiana
    Jacobs, Samuel
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 130 - 136
  • [8] LC-MS/MS assay for the quantitation of the ribonucleotide reductase inhibitor triapine in human plasma
    Matsumoto, Julia
    Kiesel, Brian F.
    Parise, Robert A.
    Guo, Jianxia
    Taylor, Sarah
    Huang, Marilyn
    Eiseman, Julie L.
    Ivy, S. Percy
    Kunos, Charles
    Chu, Edward
    Beumer, Jan H.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 146 : 154 - 160
  • [9] A rapid LC/MS/MS quantitation assay for naringin and its two metabolites in rats plasma
    Fang, TZ
    Wang, YG
    Ma, Y
    Su, WW
    Bai, Y
    Zhao, PY
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (02) : 454 - 459
  • [10] LC-MS/MS determination of dutasteride and its major metabolites in human plasma
    Gniazdowska, Elzbieta
    Kaza, Michal
    Bus-Kwasnik, Katarzyna
    Giebultowicz, Joanna
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 206