A four-year experience with a stereotactic computer in a small neurosurgical department

被引:7
|
作者
Brommeland, T [1 ]
Kloster, R [1 ]
Ingebrigtsen, T [1 ]
机构
[1] Univ Tromso Hosp, Dept Neurosurg, N-9038 Tromso, Norway
来源
SURGICAL NEUROLOGY | 2002年 / 57卷 / 03期
关键词
neuronavigation; frameless stereotaxy; stereotactic biopsy;
D O I
10.1016/S0090-3019(01)00700-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND A stereotactic computer with a mechanical, proprioceptive arm was acquired in 1996. The aim of this report is to review the 4-year experience with frameless, computer-aided stereotaxy in a small neurosurgical department. METHODS From 1996 to 1999 the computer was used for 121 operations. The surgical files from these operations were either retrospectively or prospectively registered. Patient and computer data, type of surgery, complications and number of surgeons were noted. The versatility, benefits, and drawbacks of the stereotactic computer were evalued based on these findinos. RESULTS Seven surgeons performed a total of 121 computer-assisted operations. The procedures consisted of 63 stereotactic tissue samplings, 44 craniotomies, 7 abscess punctures and 3 insertions of intracerebral devices (shunts and microelectrodes). Technical complications were seen in 6 cases (4.8%), but this did not affect the surgical outcome. CONCLUSIONS The stereotactic computer has enabled the department to broaden its spectrum of procedures. High precision surgery such as stereotactic biopsy has been possible without the use of a framebased system. The results indicate that even small neurosurgical units with a limited number of procedures can safely and successfully implement neuronavigation in daily routines. (C) 2002 by Elsevier Science Inc.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [41] Reduction of hospital resources utilization in vascular surgery: A four-year experience
    Roddy, SP
    O'Donnell, TF
    Iafrati, MD
    Isaacson, LA
    Bailey, VE
    Mackey, WC
    JOURNAL OF VASCULAR SURGERY, 1998, 27 (06) : 1066 - 1075
  • [42] In-school work experience and the returns to two-year and four-year colleges
    Molitor, CJ
    Leigh, DE
    ECONOMICS OF EDUCATION REVIEW, 2005, 24 (04) : 459 - 468
  • [43] Lag screw fixation for straight midline mandibulotomy: Four-year experience
    Uglesic, V
    Knezevic, P
    Kosutic, D
    Jokic, D
    ANNALS OF PLASTIC SURGERY, 2004, 52 (04) : 349 - 352
  • [44] Vacuum pack technique of temporary abdominal closure: A four-year experience
    Smith, LA
    Barker, DE
    Chase, CW
    Somberg, LB
    Brock, WB
    Burns, RP
    AMERICAN SURGEON, 1997, 63 (12) : 1102 - 1107
  • [45] Four-year experience with swan neck presternal peritoneal dialysis catheter
    Twardowski, ZJ
    Prowant, BF
    Pickett, B
    Nichols, WK
    Nolph, KD
    Khanna, R
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1996, 27 (01) : 99 - 105
  • [46] Drug-induced poisoning during pregnancy: Four-year experience
    Sert, Zekiye Soykan
    Menekse, Tugba Sanalp
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 54 : 22 - 25
  • [47] The AneuRx stent graft: Four-year results and worldwide experience 2000
    Zarins, CK
    White, RA
    Moll, FL
    Crabtree, T
    Bloch, DA
    Hodgson, KJ
    Fillinger, MF
    Fogarty, TJ
    JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) : S135 - S145
  • [48] FOUR-YEAR EXPERIENCE IN THE TREATMENT OF UPPER GASTROINTESTINAL STRICTURES WITH BALLOON DILATATION
    王晨
    王长龙
    陈炽贤
    CHINESEMEDICALJOURNAL, 1991, (02)
  • [49] Sentinel node biopsy for malignant melanoma: Analysis of a four-year experience
    Caggiati, A
    Potenza, C
    Gabrielli, F
    Passarelli, F
    Tartaglione, G
    TUMORI, 2000, 86 (04) : 332 - 335
  • [50] A four-year experience with Holmium-YAG laser: parameters of use
    Cecchetti, W.
    Cerruto, M. A.
    Dal Bianco, M.
    Milani, C.
    Zattoni, F.
    UROLOGIA JOURNAL, 2007, 74 (03) : 155 - 159