Calibration of a lumped simulation model for double-skin facade systems

被引:55
作者
Park, CS [1 ]
Augenbroe, G
Messadi, T
Thitisawat, M
Sadegh, N
机构
[1] Georgia Inst Technol, Coll Architecture, PhD Program, Atlanta, GA 30332 USA
[2] Univ Arkansas, Sch Architecture, Fayetteville, AR 72701 USA
[3] Georgia Inst Technol, Sch Mech Engn, Atlanta, GA 30332 USA
关键词
lumped model; double-skin facade; calibration; parameter estimation;
D O I
10.1016/j.enbuild.2004.04.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper describes the calibration of a simulation model of double-skin facade systems with controlled rotating louvers and ventilation openings. The approach is based on a parameter estimation technique and in situ monitoring of a full-scale element mounted on the south facing facade of an existing building. Contrary to similar work that attempts to derive the behavior from detailed modeling of the physical transport phenomena, the new approach is based on a postulated "minimalistic" lumped model, which is calibrated on in-situ measurements. It is found that the calibrated model is surprisingly accurate and ideally suited for use in the ensuing optimal control and performance studies. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:1117 / 1130
页数:14
相关论文
共 22 条
[1]  
[Anonymous], J GLOBAL OPTIM, DOI DOI 10.1007/BF00121304
[2]  
ASHRAE, 1997, ASHRAE Handbook SI (Fundamentals)
[3]  
Clarke J. A., 2001, Energy Simulation in Building Design, V2nd, DOI DOI 10.4324/9780080505640
[4]   Building a grey box model to model the energy and mass transfer in an imperfectly mixed fluid by using experimental data [J].
DeMoor, M ;
Berckmans, D .
MATHEMATICS AND COMPUTERS IN SIMULATION, 1996, 42 (2-3) :233-244
[5]   Grey boxes used to represent buildings with a minimum number of geometric and thermal parameters [J].
Déqué, F ;
Ollivier, F ;
Poblador, A .
ENERGY AND BUILDINGS, 2000, 31 (01) :29-35
[6]  
*FLOM LTD, 2001, FLOVENT VERS 3 2 MAN
[7]   Optimal operation of a south double-skin facade [J].
Gratia, E ;
De Herde, A .
ENERGY AND BUILDINGS, 2004, 36 (01) :41-60
[8]   Is day natural ventilation still possible in office buildings with a double-skin facade? [J].
Gratia, E ;
De Herde, A .
BUILDING AND ENVIRONMENT, 2004, 39 (04) :399-409
[9]   Natural ventilation in a double-skin facade [J].
Gratia, E ;
De Herde, A .
ENERGY AND BUILDINGS, 2004, 36 (02) :137-146
[10]  
HENSEN JLM, 1991, THESIS U EINDHOVEN