Implantable Cardioverter Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices: Utilization Patterns, Related Procedures, and Complications

被引:14
|
作者
Alvarez, Paulino A. [1 ,2 ]
Sperry, Brett W. [1 ,3 ]
Perez, Antonio L. [1 ]
Yaranov, Dmitry M. [1 ]
Randhawa, Varinder [1 ]
Luthman, Jacob [1 ]
Cantillon, Daniel J. [1 ]
Starling, Randall C. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Univ Iowa, Dept Cardiovasc Med, Iowa City, IA USA
[3] St Lukes Hosp Kansas City, Mid Amer Heart Inst, Kansas City, MO USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 14期
关键词
implanted cardioverter defibrillator; infection; left ventricular assist device; ARRHYTHMIAS;
D O I
10.1161/JAHA.118.011813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The effect of implantable cardioverter defibrillators (ICD) in patients with continuous flow left ventricular assist devices (LVADs) on outcomes has not been evaluated in a randomized clinical trial. Methods and Results-This is a retrospective single-center study that included patients who underwent continuous flow LVAD implantation at the Cleveland Clinic between October 2004 and March 2017. Patients were evaluated according to the presence or absence of ICD at the time of LVAD insertion. Among 486 patients in the study cohort, 387 (79.6%) had an ICD before LVAD insertion. Patients with ICD before LVAD were older and had lower use of pre-LVAD inotropes, extracorporeal membrane oxygenation, and mechanical ventilation. There were 81 patients (21.4% of patients with ICD) who required 93 procedures after LVAD: 74 generator exchanges, 12 lead revisions, and 7 complete system removals because of infection. Of the 99 patients without ICD, 52 (53%) underwent ICD implantation: 29 for primary prevention and 23 for secondary prevention. Patients were followed for a median of 401 (interquartile range 150-966) days. The presence of a pre-LVAD ICD was not associated with mortality in a multivariable model (hazard ratio 1.19, 95% CI 0.73-1.93, P=0.492), nor was the presence of an ICD at any point when analyzed as a time-varying covariate (hazard ratio 1.05, 95% CI 0.50-2.20, P=0.907). Conclusions-There is no apparent mortality benefit associated with an ICD in a contemporary cohort of patients with continuous flow LVADs to balance considerable morbidity involving ICD-related procedures and complications.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Endothelial Function in Patients With Continuous-Flow Left Ventricular Assist Devices
    Poredos, Pavel
    Jezovnik, Mateja K.
    Radovancevic, Rajko
    Gregoric, Igor D.
    ANGIOLOGY, 2021, 72 (01) : 9 - 15
  • [42] Implantable cardioverter-defibrillator shocks in patients with a left ventricular assist device
    Ambardekar, Amrut V.
    Allen, Larry A.
    Lindenfeld, JoAnn
    Lowery, Christopher M.
    Cannon, Anne P.
    Cleveland, Joseph C., Jr.
    Brieke, Andreas
    Sauer, William H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (07) : 771 - 776
  • [43] Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator
    Boudghene-Stambouli, Fanny
    Boule, Stephane
    Goeminne, Celine
    Botcherby, Edward
    Marquie, Christelle
    Kouakam, Claude
    Guedon-Moreau, Laurence
    Schurtz, Guillaume
    de Groote, Pascal
    Lamblin, Nicolas
    Fertin, Marie
    Robin, Emmanuel
    Brigadeau, Francois
    Klug, Didier
    Lacroix, Dominique
    Meurice, Jonathan
    Wissocque, Ludivine
    Vincentelli, Andre
    Kacet, Salem
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (02) : 177 - 184
  • [44] Safety of enoxaparin in patients implanted with continuous flow left ventricular assist devices
    Klosko, Rachel C.
    Whitson, Bryan
    Lampert, Brent
    Mclaughlin, Eric
    Orzel, Libby
    ARTIFICIAL ORGANS, 2024, : 639 - 648
  • [45] Frequency and Temporal Patterns of Implantable Cardiac Defibrillator Therapies in Patients With Left Ventricular Assist Devices
    Appelbaum, Jason
    Weragoda, Ramal
    Lloyd, Michael
    Langberg, Jonathan
    Hoskins, Michael
    CIRCULATION, 2013, 128 (22)
  • [46] Vasoplegia from Continuous Flow Left Ventricular Assist Devices
    Shyama Sathianathan
    Geetha Bhat
    Robert Dowling
    Current Cardiology Reports, 2021, 23
  • [47] Vasoplegia from Continuous Flow Left Ventricular Assist Devices
    Sathianathan, Shyama
    Bhat, Geetha
    Dowling, Robert
    CURRENT CARDIOLOGY REPORTS, 2021, 23 (08)
  • [48] Ventricular Tachycardia in Patients with Continuous Flow Left Ventricular Assist Devices: A Single Center Experience
    Shivamurthy, Poojita
    Ganga, Harsha
    Ingrassia, Joseph
    Slim, Hanna B.
    Radojevic, Joseph
    Gluck, Jason
    Kluger, Jeffrey
    CIRCULATION, 2014, 130
  • [49] Heart transplantation outcomes in patients with continuous-flow left ventricular assist device-related complications
    Quader, Mohammed A.
    Wolfe, Luke G.
    Kasirajan, Vigneshwar
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (01) : 75 - 81
  • [50] Left Ventricular Filling Pressures Contribute to Exercise Limitation in Patients with Continuous Flow Left Ventricular Assist Devices
    Koshy, Aaron
    Bouzas-Cruz, Noelia
    Okwose, Nduka C.
    Fernandez, Oscar Gonzalez
    Green, Thomas
    Woods, Andrew
    Robinson-Smith, Nicola
    Tovey, Sian
    McDiarmid, Adam
    Parry, Gareth
    Schueler, Stephan
    Jakovljevic, Djordje G.
    MacGowan, Guy A.
    ASAIO JOURNAL, 2020, 66 (03) : 247 - 252