Implantable Cardioverter Defibrillators in Patients With Continuous Flow Left Ventricular Assist Devices: Utilization Patterns, Related Procedures, and Complications

被引:14
|
作者
Alvarez, Paulino A. [1 ,2 ]
Sperry, Brett W. [1 ,3 ]
Perez, Antonio L. [1 ]
Yaranov, Dmitry M. [1 ]
Randhawa, Varinder [1 ]
Luthman, Jacob [1 ]
Cantillon, Daniel J. [1 ]
Starling, Randall C. [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Univ Iowa, Dept Cardiovasc Med, Iowa City, IA USA
[3] St Lukes Hosp Kansas City, Mid Amer Heart Inst, Kansas City, MO USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2019年 / 8卷 / 14期
关键词
implanted cardioverter defibrillator; infection; left ventricular assist device; ARRHYTHMIAS;
D O I
10.1161/JAHA.118.011813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The effect of implantable cardioverter defibrillators (ICD) in patients with continuous flow left ventricular assist devices (LVADs) on outcomes has not been evaluated in a randomized clinical trial. Methods and Results-This is a retrospective single-center study that included patients who underwent continuous flow LVAD implantation at the Cleveland Clinic between October 2004 and March 2017. Patients were evaluated according to the presence or absence of ICD at the time of LVAD insertion. Among 486 patients in the study cohort, 387 (79.6%) had an ICD before LVAD insertion. Patients with ICD before LVAD were older and had lower use of pre-LVAD inotropes, extracorporeal membrane oxygenation, and mechanical ventilation. There were 81 patients (21.4% of patients with ICD) who required 93 procedures after LVAD: 74 generator exchanges, 12 lead revisions, and 7 complete system removals because of infection. Of the 99 patients without ICD, 52 (53%) underwent ICD implantation: 29 for primary prevention and 23 for secondary prevention. Patients were followed for a median of 401 (interquartile range 150-966) days. The presence of a pre-LVAD ICD was not associated with mortality in a multivariable model (hazard ratio 1.19, 95% CI 0.73-1.93, P=0.492), nor was the presence of an ICD at any point when analyzed as a time-varying covariate (hazard ratio 1.05, 95% CI 0.50-2.20, P=0.907). Conclusions-There is no apparent mortality benefit associated with an ICD in a contemporary cohort of patients with continuous flow LVADs to balance considerable morbidity involving ICD-related procedures and complications.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Intraventricular Flow Patterns in Patients Treated with Left Ventricular Assist Devices
    Rossini, Lorenzo
    Braun, Oscar O.
    Brambatti, Michela
    Benito, Yolanda
    Mizeracki, Adam
    Miramontes, Marissa
    Nguyen, Cathleen
    Martinez-Legazpi, Pablo
    Almeida, Shone
    Kraushaar, Megan
    Vu, Vi
    May-Newman, Karen
    Bermejo, Javier
    Adler, Eric D.
    Kahn, Andrew M.
    Del Alamo, Juan C.
    ASAIO JOURNAL, 2021, 67 (01) : 74 - 83
  • [32] Influence of a fully magnetically levitated left ventricular assist device on functional interrogation of implantable cardioverter defibrillators
    Schukro, Christoph
    Schloeglhofer, Thomas
    Khazen, Cesar
    Roehrich, Michael
    Laufer, Guenther
    Zimpfer, Daniel
    Wiedemann, Dominik
    CLINICAL CARDIOLOGY, 2019, 42 (10) : 914 - 918
  • [33] Current Review of Implantable Cardioverter Defibrillator Use in Patients With Left Ventricular Assist Device
    Boulet, Jacinthe
    Massie, Emmanuelle
    Mondesert, Blandine
    Lamarche, Yoan
    Carrier, Michel
    Ducharme, Anique
    CURRENT HEART FAILURE REPORTS, 2019, 16 (06) : 229 - 239
  • [34] Implantable Cardioverter-Defibrillator Use in Patients With Left Ventricular Assist Devices A Systematic Review and Meta-Analysis
    Vakil, Kairav
    Kazmirczak, Felipe
    Sathnur, Neeraj
    Adabag, Selcuk
    Cantillon, Daniel J.
    Kiehl, Erich L.
    Koene, Ryan
    Cogswell, Rebecca
    Anand, Inderjit
    Roukoz, Henri
    JACC-HEART FAILURE, 2016, 4 (10) : 772 - 779
  • [35] Catheter Ablation for Ventricular Tachyarrhythmias in Patients Supported by Continuous-Flow Left Ventricular Assist Devices
    Garan, Arthur R.
    Iyer, Vivek
    Whang, William
    Mody, Kanika P.
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Te-Frey, Rosie
    Takayama, Hiroo
    Naka, Yoshifumi
    Garan, Hasan
    Jorde, Ulrich P.
    Uriel, Nir
    ASAIO JOURNAL, 2014, 60 (03) : 311 - 316
  • [36] Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review
    Gordon, Jonathan S.
    Maynes, Elizabeth J.
    O'Malley, Thomas J.
    Pavri, Behzad B.
    Tchantchaleishvili, Vakhtang
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 61 (01) : 1 - 10
  • [37] Characteristics of Ventricular Tachycardia Ablation in Patients With Continuous Flow Left Ventricular Assist Devices
    Sacher, Frederic
    Reichlin, Tobias
    Zado, Erica S.
    Field, Michael E.
    Viles-Gonzalez, Juan F.
    Peichl, Petr
    Ellenbogen, Kenneth A.
    Maury, Philippe
    Dukkipati, Srinivas R.
    Picard, Francois
    Kautzner, Josef
    Barandon, Laurent
    Koneru, Jayanthi N.
    Ritter, Philippe
    Mahida, Saagar
    Calderon, Joachim
    Derval, Nicolas
    Denis, Arnaud
    Cochet, Hubert
    Shepard, Richard K.
    Corre, Jerome
    Coffey, James O.
    Garcia, Fermin
    Hocini, Meleze
    Tedrow, Usha
    Haissaguerre, Michel
    d'Avila, Andre
    Stevenson, William G.
    Marchlinski, Francis E.
    Jais, Pierre
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (03) : 592 - 597
  • [38] Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review
    Jonathan S. Gordon
    Elizabeth J. Maynes
    Thomas J. O’Malley
    Behzad B. Pavri
    Vakhtang Tchantchaleishvili
    Journal of Interventional Cardiac Electrophysiology, 2021, 61 : 1 - 10
  • [39] Acquired and Hereditary Hypercoagulable States in Patients with Continuous Flow Left Ventricular Assist Devices: Prevalence and Thrombotic Complications
    Alvarez, Paulino
    Cordero-Reyes, Andrea M.
    Uribe, Cesar
    de Hoyos, Patricio
    Martinez, Donna
    Bhimaraj, Arvind
    Trachtenberg, Barry H.
    Ashrith, Guha
    Torre-Amione, Guillermo
    Loebe, Mathias
    Amione-Guerra, Javier
    Rice, Lawrence
    Estep, Jerry D.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (07) : 501 - 511
  • [40] Management of hypertension in patients supported with continuous flow left ventricular assist devices
    Krishnarao, Krithika
    Krim, Selim R.
    CURRENT OPINION IN CARDIOLOGY, 2023, 38 (04) : 281 - 286