Mechanical characterization and identification of material parameters of porcine aortic valve leaflets

被引:8
作者
Laville, Colin [1 ]
Pradille, Christophe [2 ]
Tillier, Yannick [1 ]
机构
[1] PSL Res Univ, CEMEF Ctr Mise Forme Mat, MINES ParisTech, CNRS UMR 7635, CS10 207, F-06904 Sophia Antipolis, France
[2] Mat Xper Co, 19 Traverse Barri, F-06560 Valbonne, France
关键词
GLOBAL OPTIMIZATION; BEHAVIOR; ELASTIN; SYSTEM; LAYERS; DAMAGE; MODEL;
D O I
10.1016/j.jmbbm.2020.104036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The ideal artificial heart valve does not exist yet. Understanding of mechanical and structural properties of natural tissues is necessary to improve the design of biomimetic aortic valve. Besides these properties are needed for the finite element modeling as input parameters. In this study we propose a new method combining biaxial tests and digital image correlation. These tests are carried out on porcine aortic valves. In this work, we use a modified version of the HGO (Holzapfel-Gasser-Ogden) model which is classically used for hyper-elastic and anisotropic soft tissues. This model can include fiber orientation. The identification of HGO model parameters can be determined using experimental data and two different protocols. One protocol is based on the identification of collagen fibers orientation as well as the mechanical parameters. The second one, is based on a complementary experiment to determine orientation (confocal laser scanning microscope). Both lead to determine different sets of material parameters. We show that the model is more likely to reproduce the actual mechanical behavior of the heart valves in the second case and that a minimum of three different loading conditions for the biaxial tensile tests is required to obtain a relevant set of parameters.
引用
收藏
页数:9
相关论文
共 31 条
  • [1] Avril S, 2017, CISM COURSES LECT, V573, P37, DOI 10.1007/978-3-319-45071-1_2
  • [2] Biaxial mechanical properties of the natural and glutaraldehyde treated aortic valve cusp - Part I: Experimental results
    Billiar, KL
    Sacks, MS
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (01): : 23 - 30
  • [3] Interlayer micromechanics of the aortic heart valve leaflet
    Buchanan, Rachel M.
    Sacks, Michael S.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2014, 13 (04) : 813 - 826
  • [4] On the use of a four-cameras stereovision system to characterize large 3D deformation in elastomers
    Candau, Nicolas
    Pradille, Christophe
    Bouvard, Jean-Luc
    Billon, Noelle
    [J]. POLYMER TESTING, 2016, 56 : 314 - 320
  • [5] On the biomechanical role of glycosaminoglycans in the aortic heart valve leaflet
    Eckert, Chad E.
    Fan, Rong
    Mikulis, Brandon
    Barron, Mathew
    Carruthers, Christopher A.
    Friebe, Vincent M.
    Vyavahare, Naren R.
    Sacks, Michael S.
    [J]. ACTA BIOMATERIALIA, 2013, 9 (01) : 4653 - 4660
  • [6] Planar biaxial testing of soft biological tissue using rakes: A critical analysis of protocol and fitting process
    Fehervary, Heleen
    Smoljkic, Marija
    Sloten, Jos Vander
    Famaey, Nele
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 61 : 135 - 151
  • [7] Ferreira T., 2012, IMAGEJ USER GUIDE
  • [8] Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
    Gasser, TC
    Ogden, RW
    Holzapfel, GA
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2006, 3 (06) : 15 - 35
  • [9] Novel optical system for in vitro quantification of full surface strain fields in small arteries: II. Correction for refraction and illustrative results
    Genovese, K.
    Lee, Y. U.
    Humphrey, J. D.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (03) : 227 - 237
  • [10] Polymeric heart valves: new materials, emerging hopes
    Ghanbari, Hossein
    Viatge, Helene
    Kidane, Asmeret G.
    Burriesci, Gaetano
    Tavakoli, Mehdi
    Seifalian, Alexander M.