Survival and Appropriate Device Interventions in Recipients of Cardioverter Defibrillators Implanted for the Primary Versus Secondary Prevention of Sudden Cardiac Death

被引:16
作者
Stockburger, Martin [1 ]
Krebs, Alice [1 ]
Nitardy, Aischa [1 ]
Habedank, Dirk [1 ]
Celebi, Oezlem [1 ]
Knaus, Thomas [1 ]
Dietz, Rainer [1 ]
机构
[1] Charite, Campus Virchow Klinikum, Med Klin Schwerpunkt Kardiol, D-13353 Berlin, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2009年 / 32卷
关键词
implantable cardioverter defibrillator; sudden cardiac death; ventricular tachyarrhythmia; survival analysis; primary prevention; secondary prevention; MORTALITY;
D O I
10.1111/j.1540-8159.2008.02222.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Implantable cardioverter-defibrillators (ICD) implanted after an episode of ventricular tachyarrhythmia (VTA) or in patients at high risk of VTA lower the long-term mortality. Comparisons of the clinical outcomes of the two indications are scarce. Methods: The study enrolled 360 consecutive ICD recipients. The device was implanted for secondary prevention in 150 patients, whose mean age was 60 14 years, and mean left ventricular ejection fraction (LVEF) was 40 +/- 16%, and for primary prevention in 210 patients, whose mean age was 61 11 years, and mean LVEF was 31 +/- 13 %. All-cause mortality and time to first appropriate ICD therapy were measured. Results: The two study groups were similar with respect to age and prevalence of coronary artery disease. Mean LVEF was higher in the secondary prevention group (P = 0.001). Cox regression analysis revealed a significantly shorter time to first appropriate ICD therapy in the secondary prevention group (HR = 0.51, 95% CI = 0.30 - 0.87, P = 0.01). Over a mean follow-up of 37 19 months, the all-cause mortality in the overall population was 12.7%, and was similar in both subgroups (HR = 0.99, 95% CI 0.55-1.77, P = 0.97). Conclusions: The long-term mortality in this unselected population of ICD recipients was low. Patients treated for secondary prevention received earlier appropriate ICD therapy than patients treated for primary prevention. Long-term mortality was similar in both groups. The higher VT incidence of VTA was effectively treated by the ICD and was not associated with a higher Mortality. (PACE 2009; 32:S16-S20)
引用
收藏
页码:S16 / S20
页数:5
相关论文
共 13 条
[1]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[2]   Potential benefit from implantable cardioverter-defibrillator therapy in patients with and without heart failure [J].
Böcker, D ;
Bänsch, D ;
Heinecke, A ;
Weber, M ;
Brunn, J ;
Hammel, D ;
Borggrefe, M ;
Breithardt, G ;
Block, P .
CIRCULATION, 1998, 98 (16) :1636-1643
[3]   Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials [J].
Connolly, SJ ;
Hallstrom, AP ;
Cappato, R ;
Schron, EB ;
Kuck, KH ;
Zipes, DP ;
Greene, HL ;
Boczor, S ;
Domanski, M ;
Follmann, D ;
Gent, M ;
Roberts, RS .
EUROPEAN HEART JOURNAL, 2000, 21 (24) :2071-2078
[4]   Mortality, morbidity, and complications in 3,344 patients with implantable cardioverter defibrillators: Results from the German ICD Registry EURID [J].
Gradaus, R ;
Block, M ;
Brachmann, J ;
Breithardt, G ;
Huber, HG ;
Jung, W ;
Kranig, W ;
Mletzko, RU ;
Schoels, W ;
Seidl, K ;
Senges, J ;
Siebels, J ;
Steinbeck, G ;
Stellbrink, C ;
Andresen, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (07) :1511-1518
[5]  
Gregoratos Gabriel, 2002, Circulation, V106, P2145, DOI 10.1161/01.CIR.0000035996.46455.09
[6]  
Klein Richard C, 2003, J Cardiovasc Electrophysiol, V14, P940, DOI 10.1046/j.1540-8167.2003.01554.x
[7]  
McAnulty J, 1997, NEW ENGL J MED, V337, P1576
[8]   Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction [J].
Moss, AJ ;
Zareba, W ;
Hall, WJ ;
Klein, H ;
Wilber, DJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Brown, MW ;
Andrews, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (12) :877-883
[9]   Is dual-chamber programming inferior to single-chamber programming in an implantable cardioverter-defibrillator? Results of the INTRINSIC RV (inhibition of unnecessary RV pacing with AVSH in ICDs) study [J].
Olshansky, Brian ;
Day, John D. ;
Moore, Stephen ;
Gering, Lawrence ;
Rosenbaum, Murray ;
McGuire, Maureen ;
Brown, Scott ;
Lerew, Darin R. .
CIRCULATION, 2007, 115 (01) :9-16
[10]  
POOLE JE, 2006, HEART RHYTHM, V3, pS40