Measurement of serotonin in platelet depleted plasma by liquid chromatography tandem mass spectrometry

被引:29
作者
Monaghan, Phillip J. [1 ,2 ]
Brown, Heather A. [3 ]
Houghton, Lesley A. [4 ]
Keevil, Brian G. [2 ]
机构
[1] Wirral Univ Teaching Hosp, Dept Clin Biochem, Wirral CH49 5PE, Merseyside, England
[2] S Manchester Univ Hosp Trust, Dept Clin Biochem, Manchester M23 9LT, Lancs, England
[3] Waters MS Technol Ctr, Manchester M22 5PP, Lancs, England
[4] S Manchester Univ Hosp Trust, Neurogastroenterol Unit, Manchester M23 9LT, Lancs, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 22期
关键词
Serotonin; LC-MS/MS; Protein precipitation; Functional gastrointestinal disorders; IRRITABLE-BOWEL-SYNDROME; WHOLE-BLOOD; 5-HYDROXYTRYPTAMINE; PREDOMINANT; VALIDATION; RELEASE;
D O I
10.1016/j.jchromb.2009.05.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
5-Hydroxytryptamine (5-HT) in human platelet depleted plasma (PDP) is a biomarker in functional gastrointestinal disorders (FGID), with levels reflecting acute changes in circulating 5-HT concentration. POP 5-HT is currently measured by reversed phase high performance liquid chromatography (HPLC) fluorimetric detection. We have developed a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method that is two times more rapid than the current HPLC methodology. Our method employs a simple protein precipitation requiring no further downstream sample preparation. 10 mu L of extract was injected directly onto a SecurityGuard SCX cation exchange column followed by isocratic elution onto an Onyx Monolithic C18 analytical column and methanolic gradient elution. Eluant was connected directly to a Quattro Premier XE tandem mass spectrometer operating in ES+ mode. We detected multiple reaction monitoring transitions m/z 160 > 114.9 and m/z 164.1 > 118.9 for 5-HT and d(4)-5-HT, respectively. 5-HT and d(4)-5-HT co-eluted at 2.79 min and cycle time between injections was 6 min. Mean recovery was 98%, limit of detection 1.5 nmol/L, lower limit of quantification 5 nmol/L, linearity to 1000 nmol/L(r(2) = 0.999), imprecision <10% and bias <13.4%. 5-HT eluted with no ion suppression. No interference was found with L-tryptophan or 5-hydroxyindoleacetic acid (5-HIAA). This assay was compared to a previously published HPLC method. Passing-Bablok regression analysis showed LC-MS/MS=0.91 (HPLC)-0.83, r(2) = 0.97, n = 80. Bland Altman analysis showed general agreement, with a mean bias of 3.3 nmol/L We have developed a simple and robust assay for POP 5-HT that will increase throughput for clinical trials. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2163 / 2167
页数:5
相关论文
共 50 条
  • [41] Liquid chromatography-tandem mass spectrometry for the determination of jaceosidin in rat plasma
    Song, Won Young
    Kim, Nam Jin
    Kim, Sung Yeon
    Lee, Hye Suk
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (02) : 381 - 386
  • [42] Determination of solifenacin in human plasma by liquid chromatography-tandem mass spectrometry
    Macek, Jan
    Ptacek, Pavel
    Klima, Josef
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31): : 3327 - 3330
  • [43] Determination of telmisartan in human plasma by liquid chromatography-tandem mass spectrometry
    Li, PF
    Wang, YW
    Wang, Y
    Tang, YB
    Fawcett, JP
    Cui, YM
    Gu, JK
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 126 - 129
  • [44] Measurement of cyclooxygenase inhibition using liquid chromatography-tandem mass spectrometry
    Cao, Hongmei
    Yu, Rui
    Tao, Yi
    Nikolic, Dejan
    van Breemen, Richard B.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (01) : 230 - 235
  • [45] Liquid chromatography-tandem mass spectrometry in clinical laboratory protein measurement
    Ma, Yichen
    Wang, Danchen
    Li, Honglei
    Ma, Xiaoli
    Zou, Yutong
    Mu, Danni
    Yu, Songlin
    Cheng, Xinqi
    Qiu, Ling
    CLINICA CHIMICA ACTA, 2024, 562
  • [46] Development of a liquid chromatography-tandem mass spectrometry method for assaying cenobamate in rat plasma
    Oh, Ji-Hoon
    Jeong, Jong-Woo
    Ji, Yu-Geun
    Shin, Yu-Mi
    Lee, Kyeong-Ryoon
    Cho, Kwan Hyung
    Koo, Tae-Sung
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (17-18) : 992 - 997
  • [47] Liquid chromatography-tandem mass spectrometry measurement of 26 steroid hormones in human serum and plasma samples
    Jia, Yongjuan
    Liu, Xingli
    Xu, Li
    Zhao, Jinbao
    Ni, Junjun
    Zhang, Yuanyuan
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (12) : 2358 - 2370
  • [48] Plasma PCSK9 measurement by liquid chromatography-Tandem mass spectrometry and comparison with conventional ELISA
    Croyal, Mikael
    Fall, Fanta
    Krempf, Michel
    Thedrez, Aurelie
    Ouguerram, Khadija
    Ferchaud-Roucher, Veronique
    Aguesse, Audrey
    Billon-Crossouard, Stephanie
    Mata, Pedro
    Alonso, Rodrigo
    Lambert, Gilles
    Nobecourt, Estelle
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1044 : 24 - 29
  • [49] Determination of mycotoxins in cereals by liquid chromatography tandem mass spectrometry
    Soleimany, F.
    Jinap, S.
    Abas, F.
    FOOD CHEMISTRY, 2012, 130 (04) : 1055 - 1060
  • [50] Liquid Chromatography-tandem Mass Spectrometry for Quantification of Dioscin in Rat Plasma
    Kong, Tae Yeon
    Ji, Hye Young
    Choi, Sang-Zin
    Son, Miwon
    Lee, Hye Suk
    MASS SPECTROMETRY LETTERS, 2013, 4 (03) : 55 - 58