Measurement of serotonin in platelet depleted plasma by liquid chromatography tandem mass spectrometry

被引:29
作者
Monaghan, Phillip J. [1 ,2 ]
Brown, Heather A. [3 ]
Houghton, Lesley A. [4 ]
Keevil, Brian G. [2 ]
机构
[1] Wirral Univ Teaching Hosp, Dept Clin Biochem, Wirral CH49 5PE, Merseyside, England
[2] S Manchester Univ Hosp Trust, Dept Clin Biochem, Manchester M23 9LT, Lancs, England
[3] Waters MS Technol Ctr, Manchester M22 5PP, Lancs, England
[4] S Manchester Univ Hosp Trust, Neurogastroenterol Unit, Manchester M23 9LT, Lancs, England
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 22期
关键词
Serotonin; LC-MS/MS; Protein precipitation; Functional gastrointestinal disorders; IRRITABLE-BOWEL-SYNDROME; WHOLE-BLOOD; 5-HYDROXYTRYPTAMINE; PREDOMINANT; VALIDATION; RELEASE;
D O I
10.1016/j.jchromb.2009.05.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
5-Hydroxytryptamine (5-HT) in human platelet depleted plasma (PDP) is a biomarker in functional gastrointestinal disorders (FGID), with levels reflecting acute changes in circulating 5-HT concentration. POP 5-HT is currently measured by reversed phase high performance liquid chromatography (HPLC) fluorimetric detection. We have developed a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method that is two times more rapid than the current HPLC methodology. Our method employs a simple protein precipitation requiring no further downstream sample preparation. 10 mu L of extract was injected directly onto a SecurityGuard SCX cation exchange column followed by isocratic elution onto an Onyx Monolithic C18 analytical column and methanolic gradient elution. Eluant was connected directly to a Quattro Premier XE tandem mass spectrometer operating in ES+ mode. We detected multiple reaction monitoring transitions m/z 160 > 114.9 and m/z 164.1 > 118.9 for 5-HT and d(4)-5-HT, respectively. 5-HT and d(4)-5-HT co-eluted at 2.79 min and cycle time between injections was 6 min. Mean recovery was 98%, limit of detection 1.5 nmol/L, lower limit of quantification 5 nmol/L, linearity to 1000 nmol/L(r(2) = 0.999), imprecision <10% and bias <13.4%. 5-HT eluted with no ion suppression. No interference was found with L-tryptophan or 5-hydroxyindoleacetic acid (5-HIAA). This assay was compared to a previously published HPLC method. Passing-Bablok regression analysis showed LC-MS/MS=0.91 (HPLC)-0.83, r(2) = 0.97, n = 80. Bland Altman analysis showed general agreement, with a mean bias of 3.3 nmol/L We have developed a simple and robust assay for POP 5-HT that will increase throughput for clinical trials. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2163 / 2167
页数:5
相关论文
共 50 条
  • [1] A serum and platelet-rich plasma serotonin assay using liquid chromatography tandem mass spectrometry for monitoring of neuroendocrine tumor patients
    Korse, Catharina M.
    Buning-Kager, Johanna C. G. M.
    Linders, Theodora C.
    Heijboer, Annemieke C.
    van den Broek, Daan
    Tesselaar, Margot E. T.
    van Tellingen, Olaf
    van Rossum, Huub H.
    CLINICA CHIMICA ACTA, 2017, 469 : 130 - 135
  • [2] Liquid chromatography tandem mass spectrometry for plasma metadrenalines
    Davies, S. L.
    Davison, A. S.
    CLINICA CHIMICA ACTA, 2019, 495 : 512 - 521
  • [3] Rapid measurement of plasma acylcarnitines by liquid chromatography - tandem mass spectrometry without derivatization
    Ghoshal, AK
    Guo, TD
    Soukhova, N
    Soldin, SJ
    CLINICA CHIMICA ACTA, 2005, 358 (1-2) : 104 - 112
  • [4] A liquid chromatography tandem mass spectrometry method for plasma glucagon
    Nguyen, Van Long
    Tuckwell, Phillip
    Ireland, Andrea
    Fitzpatrick, Michael
    ANALYTICAL BIOCHEMISTRY, 2023, 675
  • [5] Determination of voriconazole in human plasma by liquid chromatography-tandem mass spectrometry
    Teng, G-Sh.
    Zhao, L. -Z.
    Li, X.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (01): : 147 - 152
  • [6] Determination of celecoxib in human plasma by liquid chromatography-tandem mass spectrometry
    Ptacek, Pavel
    Klima, Josef
    Macek, Jan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 163 - 166
  • [7] Liquid chromatography-tandem mass spectrometry for the simultaneous quantitation of enmetazobactam and cefepime in human plasma
    Mameli, M.
    Vezzelli, A.
    Verze', S.
    Biondi, S.
    Motta, P.
    Greco, A.
    Michi, M.
    Breda, M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 174 : 655 - 662
  • [8] Comparative analysis of serotonin in equine plasma with liquid chromatography-tandem mass spectrometry and enzyme-linked immunosorbent assay
    Torfs, Sara C.
    Maes, An A.
    Delesalle, Catherine J.
    Deprez, Piet
    Croubels, Siska M.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2012, 24 (06) : 1035 - 1042
  • [9] Quantitation of bergenin in human plasma by liquid chromatography/tandem mass spectrometry
    Yu, Weisong
    Wang, Yingwu
    Zhang, Yunhui
    Lan, Jing
    Liu, Zeyuan
    Gu, Jingkai
    Fawcett, J. Paul
    Zhang, Dan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (1-2): : 33 - 36
  • [10] Determination of methylphenidate in plasma and saliva by liquid chromatography/tandem mass spectrometry
    Secilir, A.
    Schrier, L.
    Bijleveld, Y. A.
    Toersche, J. H.
    Jorjani, S.
    Burggraaf, J.
    van Gerven, J.
    Mathot, R. A. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 923 : 22 - 28