Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine

被引:3
|
作者
Kapoulas, S. [1 ,2 ,7 ]
Papalois, A. [3 ]
Papadakis, G. [4 ]
Tsoulfas, G. [5 ]
Christoforidis, E. [1 ]
Papaziogas, B. [1 ]
Schizas, D. [6 ]
Chatzimavroudis, G. [1 ]
机构
[1] Aristotle Univ Thessaloniki, G Gennimatas Gen Hosp, Dept Surg 2, Thessaloniki, Greece
[2] Univ Hosp Birmingham NHS Fdn Trust, Dept Upper Gastrointestinal & Bariatr Surg, Birmingham, W Midlands, England
[3] ELPEN Pharmaceut Res & Expt Ctr, Pikermi, Greece
[4] Guys & St Thomas NHS Fdn Trust, Dept Renal Transplant & Access Surg, London, England
[5] Aristotle Univ Thessaloniki, Papageorgiou Gen Hosp, Dept Surg 1, Thessaloniki, Greece
[6] Natl & Kapodistrian Univ Athens, Laikon Gen Hosp, Dept Surg 1, Athens, Greece
[7] Flat 318,Centenary Plaza,18 Holliday St, Birmingham B1 1TW, W Midlands, England
关键词
Fixation devices; Mesh; Tack; Laparoscopic hernia repair; Experimental study; VENTRAL HERNIA REPAIR; ADHESION FORMATION; SMALL-BOWEL; EROSION; METAANALYSIS; TACKS; OUTCOMES; SUTURES; BIOLOGY; MODEL;
D O I
10.1007/s10029-020-02352-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose Choice of the best possible fixation system in terms of safety and effectiveness for intraperitoneal mesh placement in hernia surgery remains controversial. The aim of the present study was to compare the performance of four fixation systems in a swine model of intraperitoneal mesh fixation. Methods Fourteen Landrace swine were utilized in the study. The experiment included two stages. Initially, four pieces of mesh (Ventralight (TM) ST) sizing 10 x 5 cm were placed and fixed intraperitoneally to reinforce 4 small full thickness abdominal wall defects created with diathermy. These defects were repaired primarily with absorbable suture before mesh implantation. Each mesh was anchored with a different tack device between Absorbatack (TM), Protack (TM), Capsure (TM), or Optifix (TM). The second stage took place after 60 days and included euthanasia, laparoscopy, and laparotomy via U-shaped incision to obtain the measurements for the outcome parameters. The primary endpoint of the study was to compare the peel strength of the compound tack/mesh from the abdominal wall. Secondary parameters were the extent and quality of visceral adhesions to the mesh, the degree of mesh shrinkage and the histological response around the tacks. Results Thirteen out of 14 animals survived the experiment and 10 were included in the final analysis. Capsure (TM) tacks had higher peel strength when compared to Absorbatack (TM) (p = 0.028); Protack (TM) (p = 0.043); and Optifix (TM) (p = 0.009). No significant differences were noted regarding the extent of visceral adhesions (Friedman's test p value 0.854), the adhesion quality (Friedman's test p value 0.506), or the mesh shrinkage (Friedman's test p value = 0.827). Four out of the ten animals developed no adhesions at all 2 months after implantation. Conclusion Capsure (TM) fixation system provided higher peel strength that the other tested devices in our swine model of intraperitoneal mesh fixation. Our findings generate the hypothesis that this type of fixation may be superior in a clinical setting. Clinical trials with long-term follow-up are required to assess the safety and efficacy of mesh fixation systems in hernia surgery.
引用
收藏
页码:567 / 579
页数:13
相关论文
共 50 条
  • [21] Experimental study of the effects of absorbable gelatin sponge and non-absorbable polyvinyl alcohol particle material used in transcatheter arterial embolization on liver tissues
    Liu, Jianping
    Wang, Shaoyi
    Xue, Xiaojun
    Hu, Tiansong
    Peng, Xinjian
    Huang, Junhao
    Zhou, Song
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2023, 25 (05)
  • [22] Randomized clinical trial comparing inguinal hernia repair with Lichtenstein technique using non-absorbable or partially absorbable mesh. Preliminary report
    Pielacinski, Konrad
    Szczepanik, Andrzej B.
    Misiak, Andrzej
    Wroblewski, Tadeusz
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2011, 6 (04) : 190 - 206
  • [23] Long-term safety and efficacy of non-absorbable abdominal mesh for apical prolapse surgery: A 10-year experience at Tertiary Care Hospital
    Aijaz, Samia
    Chughtai, Novera
    Kashif, Urooj
    Malik, Summera
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2023, 39 (02) : 567 - 571
  • [24] Prophylactic Onlay Mesh Implantation During Definitive Fascial Closure After Open Abdomen Therapy (PROMOAT): Absorbable or Non-absorbable? Methodical Description and Results of a Feasibility Study
    Schaaf, Sebastian
    Schwab, Robert
    Guesgen, Christoph
    Willms, Arnulf
    FRONTIERS IN SURGERY, 2020, 7
  • [25] A comparative study of immediate wound healing complications following cleft lip repair using either absorbable or non-absorbable skin sutures
    Alawode, Akeem O.
    Adeyemi, Michael O.
    James, Olutayo
    Ogunlewe, Mobolanle O.
    Butali, Azeez
    Adeyemo, Wasiu L.
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2018, 44 (04) : 159 - 166
  • [26] Cyanoacrylate Glue Versus Absorbable Tacks in Mesh Fixation for Laparoscopic Extraperitoneal Inguinal Hernia Repair: A Randomized Controlled Trial
    Issa, Michael
    Tacey, Mark
    Geraghty, Joshua
    Das, Atandrila
    Dhir, Arun
    Mori, Krinal
    To, Henry
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2021, 31 (03) : 291 - 297
  • [27] Mesh Fixation in Laparoscopic Incisional Hernia Repair: Glue Fixation Provides Attachment Strength Similar to Absorbable Tacks but Differs Substantially in Different Meshes
    Rieder, Erwin
    Stoiber, Martin
    Scheikl, Verena
    Poglitsch, Marcus
    Dal Borgo, Andrea
    Prager, Gerhard
    Schima, Heinrich
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2011, 212 (01) : 80 - 86
  • [28] Atraumatic laparoscopic intraperitoneal mesh fixation using a new laparoscopic device: an animal experimental study
    Villalobos, R. N.
    Mias, M. C.
    Gas, C.
    Maestre, Y.
    Nogues, M.
    Vilardell, F.
    Olsina, J. J.
    HERNIA, 2019, 23 (06) : 1123 - 1132
  • [29] Case-matched series of a non-cross-linked biologic versus non-absorbable mesh in laparoscopic ventral rectopexy
    Ogilvie, James W., Jr.
    Stevenson, Andrew R. L.
    Powar, Michael
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2014, 29 (12) : 1477 - 1483
  • [30] A Prospective Randomized Study Comparing Non-absorbable Polypropylene (Prolene®) and Delayed Absorbable Polyglactin 910 (Vicryl®) Suture Material in Mass Closure of Vertical Laparotomy Wounds