Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine

被引:3
|
作者
Kapoulas, S. [1 ,2 ,7 ]
Papalois, A. [3 ]
Papadakis, G. [4 ]
Tsoulfas, G. [5 ]
Christoforidis, E. [1 ]
Papaziogas, B. [1 ]
Schizas, D. [6 ]
Chatzimavroudis, G. [1 ]
机构
[1] Aristotle Univ Thessaloniki, G Gennimatas Gen Hosp, Dept Surg 2, Thessaloniki, Greece
[2] Univ Hosp Birmingham NHS Fdn Trust, Dept Upper Gastrointestinal & Bariatr Surg, Birmingham, W Midlands, England
[3] ELPEN Pharmaceut Res & Expt Ctr, Pikermi, Greece
[4] Guys & St Thomas NHS Fdn Trust, Dept Renal Transplant & Access Surg, London, England
[5] Aristotle Univ Thessaloniki, Papageorgiou Gen Hosp, Dept Surg 1, Thessaloniki, Greece
[6] Natl & Kapodistrian Univ Athens, Laikon Gen Hosp, Dept Surg 1, Athens, Greece
[7] Flat 318,Centenary Plaza,18 Holliday St, Birmingham B1 1TW, W Midlands, England
关键词
Fixation devices; Mesh; Tack; Laparoscopic hernia repair; Experimental study; VENTRAL HERNIA REPAIR; ADHESION FORMATION; SMALL-BOWEL; EROSION; METAANALYSIS; TACKS; OUTCOMES; SUTURES; BIOLOGY; MODEL;
D O I
10.1007/s10029-020-02352-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose Choice of the best possible fixation system in terms of safety and effectiveness for intraperitoneal mesh placement in hernia surgery remains controversial. The aim of the present study was to compare the performance of four fixation systems in a swine model of intraperitoneal mesh fixation. Methods Fourteen Landrace swine were utilized in the study. The experiment included two stages. Initially, four pieces of mesh (Ventralight (TM) ST) sizing 10 x 5 cm were placed and fixed intraperitoneally to reinforce 4 small full thickness abdominal wall defects created with diathermy. These defects were repaired primarily with absorbable suture before mesh implantation. Each mesh was anchored with a different tack device between Absorbatack (TM), Protack (TM), Capsure (TM), or Optifix (TM). The second stage took place after 60 days and included euthanasia, laparoscopy, and laparotomy via U-shaped incision to obtain the measurements for the outcome parameters. The primary endpoint of the study was to compare the peel strength of the compound tack/mesh from the abdominal wall. Secondary parameters were the extent and quality of visceral adhesions to the mesh, the degree of mesh shrinkage and the histological response around the tacks. Results Thirteen out of 14 animals survived the experiment and 10 were included in the final analysis. Capsure (TM) tacks had higher peel strength when compared to Absorbatack (TM) (p = 0.028); Protack (TM) (p = 0.043); and Optifix (TM) (p = 0.009). No significant differences were noted regarding the extent of visceral adhesions (Friedman's test p value 0.854), the adhesion quality (Friedman's test p value 0.506), or the mesh shrinkage (Friedman's test p value = 0.827). Four out of the ten animals developed no adhesions at all 2 months after implantation. Conclusion Capsure (TM) fixation system provided higher peel strength that the other tested devices in our swine model of intraperitoneal mesh fixation. Our findings generate the hypothesis that this type of fixation may be superior in a clinical setting. Clinical trials with long-term follow-up are required to assess the safety and efficacy of mesh fixation systems in hernia surgery.
引用
收藏
页码:567 / 579
页数:13
相关论文
共 50 条
  • [1] Safety and efficacy of absorbable and non-absorbable fixation systems for intraperitoneal mesh fixation: an experimental study in swine
    S. Kapoulas
    A. Papalois
    G. Papadakis
    G. Tsoulfas
    E. Christoforidis
    B. Papaziogas
    D. Schizas
    G. Chatzimavroudis
    Hernia, 2022, 26 : 567 - 579
  • [2] Absorbable versus non-absorbable tacks for mesh fixation in laparoscopic ventral hernia repair: A systematic review and meta-analysis
    Khan, Rao Muhammad Asaf
    Bughio, Mumtaz
    Ali, Baqar
    Hajibandeh, Shahin
    Hajibandeh, Shahab
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 53 : 184 - 192
  • [3] Mesh repair for postoperative wound dehiscence in the presence of infection: Is absorbable mesh safer than non-absorbable mesh?
    van't Riet M.
    de Vos van Steenwijk P.J.
    Bonjer H.J.
    Steyerberg E.W.
    Jeekel J.
    Hernia, 2007, 11 (5) : 409 - 413
  • [4] Evaluation of absorbable mesh fixation devices at various deployment angles
    Zihni, Ahmed M.
    Cavallo, Jaime A.
    Thompson, Dominic M., Jr.
    Chowdhury, Nabeel H.
    Frisella, Margaret M.
    Matthews, Brent D.
    Deeken, Corey R.
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (06): : 1605 - 1613
  • [5] Evaluation of absorbable mesh fixation devices at various deployment angles
    Ahmed M. Zihni
    Jaime A. Cavallo
    Dominic M. Thompson
    Nabeel H. Chowdhury
    Margaret M. Frisella
    Brent D. Matthews
    Corey R. Deeken
    Surgical Endoscopy, 2015, 29 : 1605 - 1613
  • [6] Comparison of Absorbable versus Non Absorbable Tackers for Fixation of Mesh in Laparoscopic Midline Anterior Abdominal Wall Hernia Repair: A Randomised Clinical Study
    Gupta, Dhruv
    Agrawal, Himanshu
    Gupta, Nikhil
    Desiraju, Yajushi
    Yelamanchi, Raghav
    Durga, C. K.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (03) : PC5 - PC9
  • [7] Letter to the editor on "Absorbable versus non-absorbable tacks for mesh fixation in laparoscopic ventral hernia repair: A systematic review and meta-analysis" [Int. J. Surg. 53 (2018) 184-192]
    Friis-Andersen, Hans
    INTERNATIONAL JOURNAL OF SURGERY, 2020, 82 : 54 - 55
  • [8] A randomised, multi-centre, prospective, double blind pilot-study to evaluate safety and efficacy of the non-absorbable Optilene® Mesh Elastic versus the partly absorbable Ultrapro® Mesh for incisional hernia repair
    Seiler, Christoph
    Baumann, Petra
    Kienle, Peter
    Kuthe, Andreas
    Kuhlgatz, Jens
    Engemann, Rainer
    Frankenberg, Moritz V.
    Knaebel, Hanns-Peter
    BMC SURGERY, 2010, 10
  • [9] Non-absorbable and partially-absorbable mesh during pelvic organ prolapse repair: A comparison of clinical outcomes
    Cho, Moon Kyoung
    Moon, Jong Ho
    Kim, Chul Hong
    INTERNATIONAL JOURNAL OF SURGERY, 2018, 55 : 5 - 8
  • [10] A randomised, multi-centre, prospective, observer and patient blind study to evaluate a non-absorbable polypropylene mesh vs. a partly absorbable mesh in incisional hernia repair
    Rickert, A.
    Kienle, P.
    Kuthe, A.
    Baumann, P.
    Engemann, R.
    Kuhlgatz, J.
    von Frankenberg, M.
    Knaebel, H. P.
    Buechler, M. W.
    LANGENBECKS ARCHIVES OF SURGERY, 2012, 397 (08) : 1225 - 1234