New Automated Chemiluminescence Immunoassay for Simultaneous but Separate Detection of Human Immunodeficiency Virus Antigens and Antibodies

被引:18
作者
Alonso, Roberto [1 ,2 ]
Roa, Paula Lopez [1 ]
Suarez, Marisol [1 ]
Bouza, Emilio [1 ,2 ]
机构
[1] Univ Gregorio Maranon, Gen Hosp, Dept Clin Microbiol & Infect Dis, Madrid, Spain
[2] Univ Complutense Madrid, Dept Med, Madrid, Spain
关键词
COMBINED P24 ANTIGEN; PERFORMANCE EVALUATION; DIAGNOSTIC WINDOW; SCREENING ASSAY; INFECTION; SENSITIVITY; COULD; HIV-2; AB;
D O I
10.1128/JCM.03486-13
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The recently launched Liaison XL Murex HIV Ab/Ag assay (DiaSorin S. p. A) uses chemiluminescence immunoassay technology for the combined qualitative determination of p24 antigen of HIV-1 and specific antibodies to both HIV-1 and HIV-2. We studied 571 serum samples from those submitted to our laboratory for HIV screening. The samples were divided into 3 subsets: subset A, 365 samples collected prospectively during 1 week; subset B, 158 samples from confirmed HIV-positive patients; and subset C, 48 samples with a positive screening result but a negative or indeterminate confirmatory test result. Our standard screening/confirmatory algorithm was used as a reference. In subset A (prospective), 5 samples were positive and 360 negative by the standard procedure. Liaison XL Murex HIV Ab/Ag correctly identified all 5 positive samples (100%) and 357 negative samples (99.2%). In subset B (confirmed positive), all 158 positive samples were in total agreement in both procedures. In subset C (screen positive only), Liaison XL Murex HIV Ab/Ag yielded accurate results in 42 out of 48 samples (87.5%). Global sensitivity and specificity for Liaison XL Murex HIV Ab/Ag (all subsets included) were 98.3% and 98.5%, respectively. Considering only nonselected prospective samples and confirmed positive samples (subsets A and B), the corresponding sensitivity and specificity values were 100% and 99.2%, respectively. The new fully automated HIV screening test showed high sensitivity and specificity compared to our standard algorithm. Its added advantage of being able to detect HIV-1 and HIV-2 antibodies and p24 antigen separately could prove useful in the diagnosis of early infections.
引用
收藏
页码:1467 / 1470
页数:4
相关论文
共 22 条
  • [1] Impact of Multi-Targeted Antiretroviral Treatment on Gut T Cell Depletion and HIV Reservoir Seeding during Acute HIV Infection
    Ananworanich, Jintanat
    Schuetz, Alexandra
    Vandergeeten, Claire
    Sereti, Irini
    de Souza, Mark
    Rerknimitr, Rungsun
    Dewar, Robin
    Marovich, Mary
    van Griensven, Frits
    Sekaly, Rafick
    Pinyakorn, Suteeraporn
    Phanuphak, Nittaya
    Trichavaroj, Rapee
    Rutvisuttinunt, Wiriya
    Chomchey, Nitiya
    Paris, Robert
    Peel, Sheila
    Valcour, Victor
    Maldarelli, Frank
    Chomont, Nicolas
    Michael, Nelson
    Phanuphak, Praphan
    Kim, Jerome H.
    [J]. PLOS ONE, 2012, 7 (03):
  • [2] Comparative evaluation of the VIDAS HIV DUO Ultra assay for combined detection of HIV-1 antigen and antibodies to HIV
    Bourlet, T
    Pretis, C
    Pillet, S
    Lesenechal, M
    Piche, K
    Pozzetto, B
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2005, 127 (02) : 165 - 167
  • [3] Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test
    Brust, S
    Duttmann, H
    Feldner, J
    Gürtler, L
    Thorstensson, R
    Simon, F
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2000, 90 (02) : 153 - 165
  • [4] Prevention of HIV-1 Infection with Early Antiretroviral Therapy
    Cohen, Myron S.
    Chen, Ying Q.
    McCauley, Marybeth
    Gamble, Theresa
    Hosseinipour, Mina C.
    Kumarasamy, Nagalingeswaran
    Hakim, James G.
    Kumwenda, Johnstone
    Grinsztejn, Beatriz
    Pilotto, Jose H. S.
    Godbole, Sheela V.
    Mehendale, Sanjay
    Chariyalertsak, Suwat
    Santos, Breno R.
    Mayer, Kenneth H.
    Hoffman, Irving F.
    Eshleman, Susan H.
    Piwowar-Manning, Estelle
    Wang, Lei
    Makhema, Joseph
    Mills, Lisa A.
    de Bruyn, Guy
    Sanne, Ian
    Eron, Joseph
    Gallant, Joel
    Havlir, Diane
    Swindells, Susan
    Ribaudo, Heather
    Elharrar, Vanessa
    Burns, David
    Taha, Taha E.
    Nielsen-Saines, Karin
    Celentano, David
    Essex, Max
    Fleming, Thomas R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (06) : 493 - 505
  • [5] Hoffmann CJ, 2007, AIDS READ, V17, P194
  • [6] Clinical performance of the novel DiaSorin LIAISON(R) XL murex: HBsAg Quant, HCV-Ab, HIV-Ab/Ag assays
    Krawczyk, Adalbert
    Hintze, Christian
    Ackermann, Jessica
    Goitowski, Birgit
    Trippler, Martin
    Gruener, Nico
    Neumann-Fraune, Maria
    Verheyen, Jens
    Fiedler, Melanie
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2014, 59 (01) : 44 - 49
  • [7] Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays
    Kwon, Jung-Ah
    Yoon, Soo-Young
    Lee, Chang-Kyu
    Lim, Chae Seung
    Lee, Kap No
    Sung, Hyun Ju
    Brennan, Catherine A.
    Devare, Sushil G.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2006, 133 (01) : 20 - 26
  • [8] Early detection of human immunodeficiency virus infection using third- and fourth-generation screening assays
    Ly, TD
    Laperche, S
    Couroucé, AM
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2001, 20 (02) : 104 - 110
  • [9] Evaluation of the sensitivity and specificity of six HIV combined p24 antigen and antibody assays
    Ly, TD
    Laperche, S
    Brennan, C
    Vallari, A
    Ebel, A
    Hunt, J
    Martin, L
    Daghfal, D
    Schochetman, G
    Devare, S
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2004, 122 (02) : 185 - 194
  • [10] Could the new HIV combined p24 antigen and antibody assays replace p24 antigen specific assays?
    Ly, Thoai Duong
    Ebel, Anne
    Faucher, Veronique
    Fihman, Valentine
    Laperche, Syria
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2007, 143 (01) : 86 - 94