Ratiometric ultrasensitive optical chemisensor film based antibiotic drug for Al(III) and Cu(II) detection

被引:32
作者
Ali, Reham [1 ,2 ]
Alminderej, Fahad M. [2 ]
Messaoudi, Sabri [2 ,3 ]
Saleh, Sayed M. [2 ,4 ]
机构
[1] Suez Univ, Fac Sci, Dept Chem, Suez 43518, Egypt
[2] Qassim Univ, Coll Sci, Dept Chem, Buraydah 51452, Saudi Arabia
[3] Carthage Univ, Fac Sci Bizerte, Jarzouna 7021, Tunisia
[4] Suez Univ, Fac Petr & Min Engn, Dept Sci & Math, Chem Branch, Suez 43721, Egypt
关键词
Ratiometric; Medical probe; TFPP; Sensor film; Al(III); Cu(II); TURN-ON; FLUORESCENT-PROBE; BODIPY DERIVATIVES; SENSOR; ALUMINUM; WATER; CHEMOSENSOR; CU2+; ION; CIPROFLOXACIN;
D O I
10.1016/j.talanta.2020.121412
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, we developed and designed a novel ratiometric optical chemisensor film for determining Al(III) and Cu (II) in low concentration ranges. The chemisensor film consists of (a) antibacterial drug Cipmfloxacin (CPFX) [1-cyclopropyl-6-fluoro1,4-dihydro-4-oxo-7-(piperaziny-1-yl) quinolone-3carboxylic acid] and (b) a reference dye 5,10,15,20- tetrakis (pentafluorophenyl) porphyrin (TFPP) in a polyvinyl chloride (PVC) matrix. PVC was applied as a homogeneous system for mixing CPFX and TFPP. The emission intensity of the CPFX in the PVC matrix varies depending on the concentrations of the Al(III) and Cu(II) ions. When the sensor film is immersed in different Al(III) concentrations, a significant fluorescence enhancement of the CPFX at (427 nm) is observed. Furthermore, the fluorescence intensity of the red emission of the TFPP dye at (644 nm) does not alter. However, in the presence of Cu(II) ions, a considerable emission quenching of the CPFX peak at (427 nm) is observed. PVC provides a great permeability and penetration facilities of dissolved ions that make the sensor film sensitive to Al (III) or Cu(II) changes outside the matrix. The film displays immense sensitivity depending on their distinctive optical characteristics of CPFX and detection capabilities within a low detection limit LOD for Al(III) and Cu(II). The LOD values were estimated to be 2.05 x 10(7) M and 1.04 x 10(7) M respectively with a relative standard deviation RSD, (1%, n=3). Density functional theory (DFT) and the time-dependent DFT (TDDFT) theoretical calculations were performed to study Cu(II) and Al(III) complexation structures and their electronic properties in solution and in the sensor film. The interference of the chemisensor film was examined using different cations and the chemisensor provides significant selectivity. We develop a new ratiometric chemisensor based on PVC polymer film for Al(III) and Cu(II) detection.
引用
收藏
页数:12
相关论文
共 74 条
[1]   Bioavailability Assessment of Metals in Freshwater Environments: A Historical Review [J].
Adams, William ;
Blust, Ronny ;
Dwyer, Robert ;
Mount, David ;
Nordheim, Eirik ;
Rodriguez, Patricio H. ;
Spry, Doug .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2020, 39 (01) :48-59
[2]   Protonated salicylaldehyde: Electronic properties [J].
Alata, Ivan ;
Omidyan, Reza ;
Broquier, Michel ;
Dedonder, Claude ;
Jouvet, Christophe .
CHEMICAL PHYSICS, 2012, 399 :224-231
[3]   Turn-on ratiometric fluorescence sensor film for ammonia based on salicylaldehyde-ionic liquid [J].
Ali, Reham ;
Elshaarawy, Reda F. M. ;
Saleh, Sayed M. .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2017, 5 (05) :4813-4818
[4]   Optical Sensing Scheme for Carbon Dioxide Using a Solvatochromic Probe [J].
Ali, Reham ;
Lang, Thomas ;
Saleh, Sayed M. ;
Meier, Robert J. ;
Wolfbeis, Otto S. .
ANALYTICAL CHEMISTRY, 2011, 83 (08) :2846-2851
[5]   Iron(III) and aluminium(III) based mixed nanostructured hydroxyphosphates as potential vaccine adjuvants: Preparation and physicochemical characterization [J].
Angelova, Nadezhda ;
Yordanov, Georgi .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2017, 535 :184-193
[6]  
Barabasz W, 2002, POL J ENVIRON STUD, V11, P199
[7]   Neurodegenerative diseases and oxidative stress [J].
Barnham, KJ ;
Masters, CL ;
Bush, AI .
NATURE REVIEWS DRUG DISCOVERY, 2004, 3 (03) :205-214
[8]   Antibiotic resistance and the environment-there and back again [J].
Berkner, Silvia ;
Konradi, Sabine ;
Schoenfeld, Jens .
EMBO REPORTS, 2014, 15 (07) :740-744
[9]   Metals in cosmetics: implications for human health [J].
Borowska, Sylwia ;
Brzoska, Malgorzata M. .
JOURNAL OF APPLIED TOXICOLOGY, 2015, 35 (06) :551-572
[10]   Selective Manipulation of ICT and PET Processes in Styryl-Bodipy Derivatives: Applications in Molecular Logic and Fluorescence Sensing of Metal Ions [J].
Bozdemir, O. Altan ;
Guliyev, Ruslan ;
Buyukcakir, Onur ;
Selcuk, Sencer ;
Kolemen, Safacan ;
Gulseren, Gulcihan ;
Nalbantoglu, Tugrul ;
Boyaci, Hande ;
Akkaya, Engin U. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2010, 132 (23) :8029-8036