Self-Powered Detectors for Test Blanket Modules in ITER

被引:0
|
作者
Raj, Prasoon [1 ]
Angelone, Maurizio [2 ]
Fischer, Ulrich [1 ]
Klix, Axel [1 ]
机构
[1] KIT, D-76344 Eggenstein Leopoldshafen, Germany
[2] ENEA CR, I-00044 Rome, Italy
来源
2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD) | 2016年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Self-powered detectors are under test for application as neutron and gamma flux monitors in ITER test blanket modules. This paper presents the experimental setup designed for the first tests with flat sandwich-type detectors, based on beryllium and vanadium emitters. Results from the irradiation experiments with 14MeV neutrons are shown. A preliminary understanding of the signal-creation mechanism for the tested detectors is discussed and future plans arc outlined.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Studies on Flat Sandwich-type Self-Powered Detectors for Flux Measurements in ITER Test Blanket Modules
    Raj, Prasoon
    Angelone, Maurizio
    Airing, Toralf
    Eberhardt, Klaus
    Fischer, Ulrich
    Klix, Axel
    Schwengner, Ronald
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170
  • [2] Experimental Assessment of a Flat Sandwich-Like Self-Powered Detector for Nuclear Measurements in ITER Test Blanket Modules
    Raj, Prasoon
    Angelone, Maurizio
    Doering, Toralf
    Eberhardt, Klaus
    Fischer, Ulrich
    Klix, Axel
    Schwengner, Ronald
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (09) : 2385 - 2391
  • [3] Computational study of a chromium self-powered detector for neutron flux monitoring in the test blanket module of ITER
    Raj, Prasoon
    Angelone, Maurizio
    Fischer, Ulrich
    Klix, Axel
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 908 : 10 - 17
  • [4] DEMO relevance of the test blanket modules in ITER-Application to the European test blanket modules
    Magnani, E.
    Gabriel, F.
    Boccaccini, L. V.
    Li-Puma, A.
    FUSION ENGINEERING AND DESIGN, 2010, 85 (7-9) : 1271 - 1278
  • [5] SELF-POWERED NEUTRONS DETECTORS
    VERDANT, R
    BULLETIN D INFORMATIONS SCIENTIFIQUES ET TECHNIQUES DU COMMISSARIAT A L ENERGIE ATOMIQUE, 1974, (195): : 3 - 6
  • [6] SELF-POWERED NEUTRON DETECTORS
    ACCINNI, F
    TONOLINI, F
    ENERGIA NUCLEARE, 1968, 15 (05): : 311 - &
  • [7] SELF-POWERED NEUTRON DETECTORS
    JOSLIN, CW
    NUCLEAR ENGINEERING INTERNATIONAL, 1972, 17 (192): : 399 - &
  • [8] CHARACTERIZATION OF PLATINUM SELF-POWERED DETECTORS
    LYNCH, GF
    SHIELDS, RB
    COULTER, PG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 692 - 695
  • [9] CALIBRATION OF SELF-POWERED NEUTRON DETECTORS
    SULCOSKI, MF
    WARREN, HD
    NUCLEAR SCIENCE AND ENGINEERING, 1983, 85 (03) : 245 - 250
  • [10] LONG-TERM TEST OF SELF-POWERED NEUTRON DETECTORS IN HBWR
    BRAKAS, M
    STRINDEHAG, O
    SODERLUND, B
    NUCLEAR ENGINEERING INTERNATIONAL, 1973, 18 (204): : 421 - 425