Diagnostic accuracy of microEEG: A miniature, wireless EEG device
被引:36
作者:
Grant, Arthur C.
[1
,2
]
Abdel-Baki, Samah G.
[3
]
Omurtag, Ahmet
[3
]
Sinert, Richard
[4
]
Chari, Geetha
[1
]
Malhotra, Schweta
[4
]
Weedon, Jeremy
[5
]
Fenton, Andre A.
[2
,6
]
Zehtabchi, Shahriar
[4
]
机构:
[1] Suny Downstate Med Ctr, Dept Neurol, Brooklyn, NY 11203 USA
[2] Suny Downstate Med Ctr, Dept Physiol & Pharmacol, Brooklyn, NY 11203 USA
[3] Biosignal Grp Corp, Brooklyn, NY 11226 USA
[4] Suny Downstate Med Ctr, Dept Emergency Med, Brooklyn, NY 11203 USA
[5] Suny Downstate Med Ctr, Ctr Comp Sci, Brooklyn, NY 11203 USA
[6] NYU, Ctr Neural Sci, New York, NY 10003 USA
关键词:
Sensitivity and specificity;
EEG;
Altered mental status;
Diagnostic accuracy;
INTERRATER RELIABILITY;
D O I:
10.1016/j.yebeh.2014.03.015
中图分类号:
B84 [心理学];
C [社会科学总论];
Q98 [人类学];
学科分类号:
03 ;
0303 ;
030303 ;
04 ;
0402 ;
摘要:
Measuring the diagnostic accuracy (DA) of an EEG device is unconventional and complicated by imperfect interrater reliability. We sought to compare the DA of a miniature, wireless, battery-powered EEG device ("microEEG") to a reference EEG machine in emergency department (ED) patients with altered mental status (AMS). Two hundred twenty-five ED patients with AMS underwent 3 EEGs. Two EEGs, EEG1 (Nicolet Monitor, "reference") and EEG2 (microEEG) were recorded simultaneously with EEG cup electrodes using a signal splitter. The remaining study, EEG3, was recorded with microEEG using an electrode cap immediately before or after EEG1/EEG2. The official EEG1 interpretation was considered the gold standard (EEG1-GS). EEG1, 2, and 3 were de-identified and blindly interpreted by two independent readers. A generalized mixed linear model was used to estimate the sensitivity and specificity of these interpretations relative to EEG1-GS and to compute a diagnostic odds ratio (DOR). Seventy-nine percent of EEG1-GS were abnormal. Neither the DOR nor the k(f) representing interrater reliabilities differed significantly between EEG1, EEG2, and EEG3. The mean setup time was 27min for EEG1/EEG2 and 12 min for EEG3. The mean electrode impedance of EEG3 recordings was 12.6 k Omega(SD: 31.9 k Omega). The diagnostic accuracy of microEEG was comparable to that of the reference system and was not reduced when the EEG electrodes had high and unbalanced impedances. A common practice with many scientific instruments, measurement of EEG device DA provides an independent and quantitative assessment of device performance. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:81 / 85
页数:5