An experimental investigation of the energetic performances of HFO1234yf and its binary mixtures with HFC134a in a household refrigerator

被引:54
作者
Aprea, C. [1 ]
Greco, A. [2 ]
Maiorino, A. [1 ]
机构
[1] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo 2 132, I-84084 Fisciano, SA, Italy
[2] Univ Naples Federico II, Dept Ind Engn, Ple Tecchio 80, I-80125 Naples, Italy
关键词
HFC134a; GWP; EU regulation no 517/2014; HFO1234yf; HFC134a/HFO1234yf mixture (10/90% weight); Domestic refrigerator; Energy consumption; R134A; SUBSTITUTION; R1234YF; DROP; REPLACEMENTS; HFO-1234YF; R1234ZE(E); SYSTEM; R152A;
D O I
10.1016/j.ijrefrig.2017.02.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a comparative experimental analysis between HFC134a, HFO1234yf and a refrigerant mixture of HFC134a/HFO1234yf (10/90% weight) implemented in a domestic refrigerator is introduced. Adding 10% of HFC134a to HFO1234yf, the mixture becomes nonflammable with GWP still less than 150. The experimental tests have been conducted under sub-tropical conditions in accordance with the UNI-EN-ISO15502 standard. Two kinds of tests have been shown: pull down and 1-day energy consumption. The results show that HFC134a/HFO1234yf (10/90% weight) is the best drop-in refrigerant fluid for HFC134a in the domestic refrigerator used for the experimental tests. The refrigerant mixture has the closest behaviour to that of HFC134a in terms of temperatures and pressures. Furthermore, the cycle working with the optimal charge of the mixture shows an energy saving of 16 and 14% with respect to HFC134a and HFO1234yf, respectively. (C) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 24 条
[1]  
[Anonymous], INT J REFRIGERATION
[2]  
[Anonymous], 1997, Kyoto Protocol to the UnitedNations Framework Convention on Climate Change
[3]  
[Anonymous], 2010, NIST STANDARD REFERE
[4]   An experimental evaluation of the greenhouse effect in the substitution of R134a with CO2 [J].
Aprea, C. ;
Greco, A. ;
Maiorino, A. .
ENERGY, 2012, 45 (01) :753-761
[5]   An experimental evaluation of the greenhouse effect in R22 substitution [J].
Aprea, C ;
Greco, A .
ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (09) :877-887
[6]   An experimental investigation on the substitution of HFC134a with HFO1234YF in a domestic refrigerator [J].
Aprea, Ciro ;
Greco, Adriana ;
Maiorino, Angelo .
APPLIED THERMAL ENGINEERING, 2016, 106 :959-967
[7]   The substitution of R134a with R744: An exergetic analysis based on experimental data [J].
Aprea, Ciro ;
Greco, Adriana ;
Maiorino, Angelo .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08) :2148-2159
[8]   Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Catalan, J. ;
Nebot-Andres, L. ;
Torrella, E. .
APPLIED THERMAL ENGINEERING, 2017, 110 :972-984
[9]   Experimental comparison between R152a and R134a working in a refrigeration facility equipped with a hermetic compressor [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Arauzo, I. ;
Torrella, E. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 :92-105
[10]   An experimental study of PVTx properties in the gas phase for binary mixtures of HFO-1234yf and HFC-134a [J].
Chen, Qi ;
Qi, Haiming ;
Zhang, Shiqi ;
Hong, Ronghua ;
Chen, Guangming .
FLUID PHASE EQUILIBRIA, 2015, 385 :25-28