Study on A Method for Steam Wetness Measurement based on Microwave Resonant Cavity

被引:0
|
作者
Zhang, Shu-e [1 ]
Li, Peipei [1 ]
Song, Wenmiao [1 ]
Han, Zhonghe [1 ]
机构
[1] N China Elect Power Univ, Dept Elect & Commun Engn, Baoding, Hebei Province, Peoples R China
来源
ISAPE 2008: THE 8TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION AND EM THEORY, PROCEEDINGS, VOLS 1-3 | 2008年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method for wetness measurement based on microwave resonant cavity is presented in this paper. A specially structured resonant cavity with annular grid at its both ends was designed for the wetness measurement of flowing wet air. The pneumatic characteristic of the cavity was simulated and the S parameter of it was measured. The simulation and measurement results show that it is especially suitable for the online measurement of flowing wet air wetness. The measurement system has been developed and used to measure the saturated wet air which is especially produced for studying the performance of the system. The experimental data and theoretical value are compared and the reasons for deviation between them are analyzed. The resolution of the wet air wetness measurement can reach 1.5% in the temperature range of 29 similar to 38 degrees C.
引用
收藏
页码:1034 / 1037
页数:4
相关论文
共 50 条
  • [1] A microwave cavity resonator based system for wetness measurement in steam turbine
    Li, Yongqian
    Zhao, Junchao
    Zhang, Shu'e
    Yang, Zhi
    Zhao, Hua
    IEEE ICMA 2006: PROCEEDING OF THE 2006 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-3, PROCEEDINGS, 2006, : 2100 - +
  • [2] Turbine steam wetness measurement based on cavity perturbation method
    Zhang, Shue
    Wang, Hongyun
    Kang, Lina
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2008, 28 (02): : 33 - 36
  • [3] Research on a method of wetness measurement based on resonant cavity perturbation for hydrogen in generator
    Tian, Song-feng
    Zhang, Qian
    Han, Zhong-he
    Yang, Kun
    CHALLENGES OF POWER ENGINEERING AND ENVIRONMENT, VOLS 1 AND 2, 2007, : 391 - 394
  • [4] Method for air humidity measurement based on microwave resonant cavity
    Zhang, Shu-E
    Zhao, Jun-Chao
    Li, Yong-Qian
    Xiong, Hua
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2008, 28 (02): : 27 - 32
  • [5] Microwave sensor for wetness measurement of the flowing wet steam
    Zhang, S. E.
    Liu, Y. C.
    Di, Y. J.
    Yang, Z.
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 1286 - 1290
  • [6] A method of flowing steam wetness measurment with microwave resonator
    Han Zhonghe
    Yang Kun
    Proceedings of the First International Symposium on Test Automation & Instrumentation, Vols 1 - 3, 2006, : 1751 - 1755
  • [7] Performance analysis of microwave resonator for wetness measurement in a steam turbine
    Zhao, JC
    Li, YQ
    ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 1, 2005, : 455 - 458
  • [8] Theoretical and Experimental Research on Microwave Cavity Dielectric Perturbation Technique to Measure Steam Wetness
    Qian, Jiangbo
    Han, Zhonghe
    Yan, Xiaozhe
    Li, Hengfan
    8TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS, 2014, 1592 : 205 - 214
  • [9] The measurement of the wetness of flowing wet steam by a new heating method
    Li, YF
    Wang, XJ
    Xu, TX
    Li, JM
    Jia, H
    MULTIPHASE FLOW AND HEAT TRANSFER, 1999, : 394 - 402