Comparison of air- and bone-conducted brain stem auditory evoked responses in young dogs and dogs with bilateral ear canal obstruction

被引:6
|
作者
Wolschrijn, CF [1 ]
VenkervanHaagen, AJ [1 ]
vandenBrom, WE [1 ]
机构
[1] UNIV UTRECHT,FAC VET MED,DEPT CLIN SCI COMPAN ANIM,NL-3508 TD UTRECHT,NETHERLANDS
关键词
D O I
10.1080/01652176.1997.9694763
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Brain stem responses to air- and bone-conducted stimuli were analyzed in 11 young dogs, using an in-the ear transducer and a vibrator designed for human hearing tests, respectively. The mean thresholds were 0 to 10 dB for air-conducted stimuli and 50 to 60 dB for bone-conducted stimuli. The wave forms and inter-peak latencies of the waves of the auditory evoked responses elicited by air-conducted and bone-conducted stimuli were similar. The indicated that the signals had the same origin and thus both the air-conducted and the bone-conducted responses could be considered to be auditory responses. Measurement of air-conducted and bone-conducted brain stem- evoked responses in five dogs with bilateral chronic obstructive ear disease revealed thresholds of 50 to 60 dB for air-conducted stimuli and 60 to 70 dB for bone-conducted stimuli. By comparison of these results with those in the 11 young dogs, it could be concluded that there was hearing loss other than that caused by obstruction of the ear canals.
引用
收藏
页码:158 / 162
页数:5
相关论文
共 25 条
  • [1] The latency of auditory nerve brainstem evoked responses to air- and bone-conducted stimuli
    Sohmer, H
    Freeman, S
    HEARING RESEARCH, 2001, 160 (1-2) : 111 - 113
  • [2] AUDITORY BRAIN-STEM EVOKED-RESPONSES TO BONE-CONDUCTED SIGNALS
    MAULDIN, L
    JERGER, J
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1979, 105 (11) : 656 - 661
  • [3] Bone-conducted brainstem auditory evoked response in a dog with total bilateral ear canal ablation: a case report
    Pomianowski, A.
    Adamiak, Z.
    VETERINARNI MEDICINA, 2010, 55 (01) : 39 - 41
  • [4] Gender effects in auditory brainstem responses to air- and bone-conducted clicks in neonates
    Stuart, A
    Yang, EY
    JOURNAL OF COMMUNICATION DISORDERS, 2001, 34 (03) : 229 - 239
  • [5] Comparing auditory steady-state responses amplitude evoked by simultaneous air- and bone-conducted stimulation in newborns
    Torres-Fortuny, Alejandro
    Hernandez-Perez, Heivet
    Ramirez, Belinda
    Alonso, Ileana
    Eimil, Eduardo
    Guerrero-Aranda, Alioth
    Mijares, Eleina
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2016, 55 (06) : 375 - 379
  • [7] AUDITORY BRAIN-STEM RESPONSES TO BONE-CONDUCTED TONES IN INFANTS
    STAPELLS, DR
    RUBEN, RJ
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1989, 98 (12): : 941 - 949
  • [8] Comparison of brain magnetic fields evoked by air-conducted sounds, bone-conducted audible sounds, and bone-conducted ultrasounds
    Nakagawa, S
    Nigoro, T
    Yamaguchi, M
    Tonoike, M
    Hosoi, H
    Watanabe, Y
    Imaizumi, S
    NEUROIMAGE, 2001, 13 (06) : S915 - S915
  • [9] A COMPARISON OF AUDITORY BRAIN-STEM RESPONSE THRESHOLDS AND LATENCIES ELICITED BY AIR-CONDUCTED AND BONE-CONDUCTED STIMULI
    GORGA, MP
    KAMINSKI, JR
    BEAUCHAINE, KL
    BERGMAN, BM
    EAR AND HEARING, 1993, 14 (02): : 85 - 94
  • [10] AUDITORY BRAIN-STEM RESPONSES TO AIR-CONDUCTED AND BONE-CONDUCTED CLICKS IN THE AUDIOLOGICAL ASSESSMENT OF AT-RISK INFANTS
    YANG, EY
    STUART, A
    MENCHER, GT
    MENCHER, LS
    VINCER, MJ
    EAR AND HEARING, 1993, 14 (03): : 175 - 182