Design of Experiments to Optimize an In Vitro Cast to Predict Human Nasal Drug Deposition

被引:27
作者
Shah, Samir A. [1 ]
Dickens, Colin J. [2 ]
Ward, David J. [2 ]
Banaszek, Anna A. [2 ]
George, Chris [1 ]
Horodnik, Walter [1 ]
机构
[1] Merck Res Labs, Resp Prod Dev, Summit, NJ 07901 USA
[2] Bespak Europe, Milton Keynes, Bucks, England
关键词
AQUEOUS SPRAY PUMPS; PARTICLE DEPOSITION; AIR-FLOW; DELIVERY; MODEL; AEROSOL; FORMULATION; SURROGATES; VALIDITY; REPLICA;
D O I
10.1089/jamp.2012.1011
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Previous studies showed nasal spray in vitro tests cannot predict in vivo deposition, pharmacokinetics, or pharmacodynamics. This challenge makes it difficult to assess deposition achieved with new technologies delivering to the therapeutically beneficial posterior nasal cavity. In this study, we determined best parameters for using a regionally divided nasal cast to predict deposition. Our study used a model suspension and a design of experiments to produce repeatable deposition results that mimic nasal deposition patterns of nasal suspensions from the literature. Methods: The seven-section (the nozzle locator, nasal vestibule, front turbinate, rear turbinate, olfactory region, nasopharynx, and throat filter) nylon nasal cast was based on computed tomography images of healthy humans. It was coated with a glycerol/Brij-35 solution to mimic mucus. After assembling and orienting, airflow was applied and nasal spray containing a model suspension was sprayed. After disassembling the cast, drug depositing in each section was assayed by HPLC. The success criteria for optimal settings were based on nine in vivo studies in the literature. The design of experiments included exploratory and half factorial screening experiments to identify variables affecting deposition (angles, airflow, and airflow time), optimization experiments, and then repeatability and reproducibility experiments. Results: We found tilt angle and airflow time after actuation affected deposition the most. The optimized settings were flow rate of 16 L/min, postactuation flow time of 12 sec, a tilt angle of 23 , nozzle angles of 0 , and actuation speed of 5 cm/sec. Neither cast nor operator caused significant variation of results. Conclusion: We determined cast parameters to produce results resembling suspension nasal sprays in the literature. The results were repeatable and unaffected by operator or cast. These nasal spray parameters could be used to assess deposition from new devices or formulations. For human deposition studies using radiolabeled formulations, this cast could show that radiolabel deposition represents drug deposition. Our methods could also be used to optimize settings for other casts. © Copyright 2014, Mary Ann Liebert, Inc.
引用
收藏
页码:21 / 29
页数:9
相关论文
共 36 条
[1]   The assessment of topical nasal drug distribution [J].
Aggarwal, R ;
Cardozo, A ;
Homer, JJ .
CLINICAL OTOLARYNGOLOGY, 2004, 29 (03) :201-205
[2]   Effects of physicochemical properties and other factors on systemic nasal drug delivery [J].
Behl, CR ;
Pimplaskar, HK ;
Sileno, AP ;
deMeireles, J ;
Romeo, VD .
ADVANCED DRUG DELIVERY REVIEWS, 1998, 29 (1-2) :89-116
[3]   Intranasal corticosteroids: the development of a drug delivery device for fluticasone furoate as a potential step toward improved compliance [J].
Berger, William E. ;
Godfrey, James W. ;
Slater, Anna L. .
EXPERT OPINION ON DRUG DELIVERY, 2007, 4 (06) :689-701
[4]   Characterization of nasal spray pumps and deposition pattern in a replica of the human nasal airway [J].
Cheng, YS ;
Holmes, TD ;
Gao, J ;
Guilmette, RA ;
Li, S ;
Surakitbanharn, Y ;
Rowlings, C .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2001, 14 (02) :267-280
[5]   Validation of Radiolabeling of Drug Formulations for Aerosol Deposition Assessment of Orally Inhaled Products [J].
Devadason, Sunalene G. ;
Chan, Hak-Kim ;
Haeussermann, Sabine ;
Kietzig, Claudius ;
Kuehl, Philip J. ;
Newman, Stephen ;
Sommerer, Knut ;
Taylor, Glyn .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2012, 25 :S6-S9
[6]   Breath actuated device improves delivery to target sites beyond the nasal valve [J].
Djupesland, PG ;
Skretting, A ;
Winderen, M ;
Holand, T .
LARYNGOSCOPE, 2006, 116 (03) :466-472
[7]   Recent advances in predictive understanding of respiratory tract deposition [J].
Finlay, Warren H. ;
Martin, Andrew R. .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2008, 21 (02) :189-205
[8]   The influence of spray properties on intranasal deposition [J].
Foo, Mow Yee ;
Cheng, Yung-Sung ;
Su, Wei-Chung ;
Donovan, Maureen D. .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2007, 20 (04) :495-508
[9]   Letter to the editor [J].
Garcia Arieta, Alfredo .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2007, 20 (03) :361-362
[10]   Interindividual Variability in Nasal Filtration as a Function of Nasal Cavity Geometry [J].
Garcia, Guilherme J. M. ;
Tewksbury, Earl W. ;
Wong, Brian A. ;
Kimbell, Julia S. .
JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2009, 22 (02) :139-155