Con: Patient-Prosthesis Mismatch Now Is Not an Important Consideration in the Majority of Patients After Aortic Valve Replacement

被引:1
|
作者
Vernick, William J. [1 ]
机构
[1] Hosp Univ Penn, Dept Anesthesia & Crit Care, Philadelphia, PA 19104 USA
关键词
aortic valve; aortic valve replacement; cardiac surgery; patient-prosthesis mismatch; LONG-TERM SURVIVAL; EFFECTIVE ORIFICE AREA; VENTRICULAR MASS REGRESSION; PRESSURE RECOVERY; DOPPLER-ECHOCARDIOGRAPHY; MECHANICAL PROSTHESES; HEMODYNAMIC PERFORMANCE; CONTINUITY EQUATION; HEART-VALVES; IMPACT;
D O I
10.1053/j.jvca.2013.06.018
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
引用
收藏
页码:184 / 188
页数:5
相关论文
共 50 条
  • [21] Patient-Prosthesis Mismatch After Surgical Aortic Valve Replacement: Analysis of the PARTNER Trials
    Thourani, Vinod H.
    Abbas, Amr E.
    Ternacle, Julien
    Hahn, Rebecca T.
    Makkar, Raj
    Kodali, Susheel K.
    George, Isaac
    Kapadia, Samir
    Svensson, Lars G.
    Szeto, Wilson Y.
    Herrmann, Howard C.
    Ailawadi, Gorav
    Leipsic, Jonathon
    Blanke, Philipp
    Webb, John
    Jaber, Wael A.
    Russo, Mark
    Malaisrie, S. Chris
    Yadav, Pradeep
    Clavel, Marie-Annick
    Khalique, Omar K.
    Weissman, Neil J.
    Douglas, Pamela
    Bax, Jeroen
    Dahou, Abdellaziz
    Xu, Ke
    Bapat, Vinayak
    Alu, Maria C.
    Leon, Martin B.
    Mack, Michael J.
    Pibarot, Philippe
    ANNALS OF THORACIC SURGERY, 2024, 117 (06) : 1164 - 1171
  • [22] Myocardial metabolism and diastolic function after aortic valve replacement for aortic stenosis: influence of patient-prosthesis mismatch
    Mannacio, Vito
    Di Tommaso, Luigi
    Stassano, Paolo
    De Amicis, Vincenzo
    Vosa, Carlo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (02) : 316 - 321
  • [23] Patient-Prosthesis Mismatch After Mitral Valve Replacement: A Propensity Score Analysis
    Hwang, Ho Young
    Kim, Yong Han
    Kim, Kyung-Hwan
    Kim, Ki-Bong
    Ahn, Hyuk
    ANNALS OF THORACIC SURGERY, 2016, 101 (05) : 1796 - 1803
  • [24] The effect of patient-prosthesis mismatch on survival after aortic and mitral valve replacement: a 10 year, single institution experience
    Das De, Sudeep
    Nanjappa, Ashok
    Morcos, Karim
    Aftab, Sadia
    Butler, John
    Pathi, Vivek
    Curry, Philip
    Nair, Sukumaran
    JOURNAL OF CARDIOTHORACIC SURGERY, 2019, 14 (01)
  • [25] Patient-prosthesis mismatch and long-term outcome following aortic valve replacement
    Pingpoh, Clarence
    Khargi, Krishna
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (03) : 635 - 636
  • [26] Patient-prosthesis mismatch: surgical aortic valve replacement versus transcatheter aortic valve replacement in high risk patients with aortic stenosis
    Ghanta, Ravi K.
    Kron, Irving L.
    JOURNAL OF THORACIC DISEASE, 2016, 8 (10) : E1441 - E1443
  • [27] Aortic valve replacement with sutureless prosthesis: better than root enlargement to avoid patient-prosthesis mismatch?
    Beckmann, Erik
    Martens, Andreas
    Alhadi, Firas
    Hoeffler, Klaus
    Umminger, Julia
    Kaufeld, Tim
    Sarikouch, Samir
    Koigeldiev, Nurbol
    Cebotari, Serghei
    Schmitto, Jan Dieter
    Haverich, Axel
    Shrestha, Malakh
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) : 744 - 749
  • [28] Aortic root enlargement: Is it still the best surgical tool to avoid patient-prosthesis mismatch after aortic valve replacement?
    Stefanelli, Guglielmo
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (10) : 3026 - 3027
  • [29] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [30] Does patient-prosthesis mismatch influence the results of combined aortic valve replacement and coronary bypass grafting?
    Mrowczynski, Wojciech
    Lutter, Georg
    Attmann, Tim
    Hoffmann, Grischa
    Quaden, Rene
    Cremer, Jochen
    Boening, Andreas
    KARDIOLOGIA POLSKA, 2009, 67 (08) : 865 - 874