Assessment of Steel Slag and Steel Fiber to Control Electromagnetic Shielding in High-Strength Concrete

被引:22
作者
Yuan, Tian-Feng [1 ]
Choi, Jin-Seok [1 ]
Kim, Seong-Kyum [2 ]
Yoon, Young-Soo [1 ]
机构
[1] Korea Univ, Sch Civil Environm & Architectural Engn, Seoul 02841, South Korea
[2] Kumoh Natl Inst Technol, Dept Civil Engn, Gumi 39177, South Korea
关键词
Steel slag; Steel fiber; Electrical resistivity; Electromagnetic shielding effectiveness; High-strength concrete; MECHANICAL-PROPERTIES; REINFORCED-CONCRETE; FLY-ASH; CEMENT;
D O I
10.1007/s12205-021-0629-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigates the influence of steel slag (SS) and steel fibers on the electrical resistivity and electromagnetic (EM) shielding effectiveness of high-strength concrete (HSC). It was found that the electrical resistivity of mixtures were mainly influenced by free water. Thus, the EM shielding effectiveness was evaluated without the effect of free water. HSC with 20% replacement ratio of SS exhibited slightly improved EM shielding, lower electrical resistivity, and reduced strength (compressive and flexural) compared to HSC without SS. However, HSC with steel fibers exhibited significantly improved EM shielding, lower electrical resistivity, and higher strength and toughness compared to HSC without steel fibers. An increase in the steel fiber content in the HSC significantly decreased the electrical resistivity and increased the shielding effectiveness, strength, and toughness. Regardless of the fiber content in the fiber volume fraction of mixture, the shielding effectiveness is similar for cases with and without SS whose electrical resistivity values differ only slightly. This proves that the EM shielding effectiveness was mainly affected by the electrical resistivity and these properties are significantly correlated when the electrical resistivity values differ noticeably. HSC reinforced with rebar with 50 mm spacing exhibited a 23.5-75.6% increase in the shielding effectiveness in the 600-1,000 MHz frequency region compared to pristine HSC.
引用
收藏
页码:920 / 930
页数:11
相关论文
共 38 条
[1]   Flexural responses of hybrid steel-polyethylene fiber reinforced cement composites containing high volume fly ash [J].
Ahmed, Shaikh Faiz Uddin ;
Maalej, Mohamed ;
Paramasivam, P. .
CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (05) :1088-1097
[2]  
[Anonymous], 2018, ASTM D4935-18
[3]  
[Anonymous], 2007, 299 IEEE
[4]  
[Anonymous], 2005, MILSTD1881251 DEP DE
[5]  
[Anonymous], 2016, STANDARD TEST METHOD, P1, DOI [DOI 10.1520/D0412-16, DOI 10.1520/E0384-17]
[6]  
[Anonymous], 2005, ASTM International, P8, DOI [DOI 10.1520/C0633-13, 10.1520/C1698-09.2, DOI 10.1520/C1698-09.2]
[7]   Shielding effects of reinforced concrete structures to electromagnetic fields due to GSM and UMTS systems [J].
Antonini, G ;
Orlandi, A ;
D'elia, S .
IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (03) :1582-1585
[8]   Use of fly ash as an admixture for electromagnetic interference shielding [J].
Cao, JY ;
Chung, DDL .
CEMENT AND CONCRETE RESEARCH, 2004, 34 (10) :1889-1892
[9]   ELECTROMAGNETIC SHIELDING BEHAVIOR OF WIRE-MESH SCREENS [J].
CASEY, KF .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1988, 30 (03) :298-306
[10]   MICROSTRUCTURAL ANALYSIS OF RPC (REACTIVE POWDER CONCRETE) [J].
CHEYREZY, M ;
MARET, V ;
FROUIN, L .
CEMENT AND CONCRETE RESEARCH, 1995, 25 (07) :1491-1500