PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study.

被引:74
作者
Brockett, Claire L. [1 ]
Carbone, Silvia [1 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会; “创新英国”项目; 英国生物技术与生命科学研究理事会; 英国惠康基金;
关键词
PEEK; CFR-PEEK; Knee replacement; Wear; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL JOINT ARTHROPLASTY; PERFORMANCE; CONFORMITY; PROSTHESES; BIOTRIBOLOGY; KINEMATICS; STRESS; HIP;
D O I
10.1016/j.wear.2016.12.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
New bearing materials for total joint replacement have been explored as the need to improve longevity and enhance performance is driven by the changing demands of the patient demographic. Carbon-reinforced PEEK has demonstrated good wear characteristics in experimental wear simulation in both simple geometry pin-on-plate studies and in total hip joint replacement. Carbon reinforced PEEK CFR-PEEK has the potential to reduce tibial insert thickness and preserve bone in the knee. This study investigated the wear performance of PEEK and CFR-PEEK in a low conformity total knee replacement configuration. Custom-made flat inserts were tested against cobalt-chromium femoral bearings in a knee wear simulation for a period of three million cycles. Wear was assessed gravimetrically at intervals throughout the study. The wear rates of both PEEK and CFR-PEEK were very high and almost two orders of magnitude higher than the wear rate of UHMWPE under comparable conditions. Evidence of mechanical failure of the materials, including surface cracking and delamination was observed in both materials. This study highlights that these materials may not be suitable alternatives for UHMWPE in low conformity designs. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 38 条
[21]   Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030 [J].
Kurtz, Steven ;
Ong, Kevin ;
Lau, Edmund ;
Mowat, Fionna ;
Halpern, Michael .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (04) :780-785
[22]   Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030 [J].
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Zhao, Ke ;
Kelly, Michael ;
Bozic, Kevin J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (10) :2606-2612
[23]   3-DIMENSIONAL KINEMATICS OF THE HUMAN KNEE DURING WALKING [J].
LAFORTUNE, MA ;
CAVANAGH, PR ;
SOMMER, HJ ;
KALENAK, A .
JOURNAL OF BIOMECHANICS, 1992, 25 (04) :347-357
[24]   Wear performance of all-polymer PEEK articulations for a cervical total level arthroplasty system [J].
Langohr, G. D. G. ;
Gawel, H. A. ;
Medley, J. B. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2011, 225 (J6) :499-513
[25]   The influence of design, materials and kinematics on the in vitro wear of total knee replacements [J].
McEwen, HMJ ;
Barnett, PI ;
Bell, CJ ;
Farrar, R ;
Auger, DD ;
Stone, MH ;
Fisher, J .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :357-365
[26]   Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty [J].
Pruitt, Lisa A. ;
Ansari, Farzana ;
Kury, Matt ;
Mehdizah, Amir ;
Patten, Elias W. ;
Huddlestein, James ;
Mickelson, Dayne ;
Chang, Jennifer ;
Hubert, Kim ;
Ries, Michael D. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) :476-484
[27]   The conflicting requirements of laxity and conformity in total knee replacement [J].
Sathasivam, S ;
Walker, PS .
JOURNAL OF BIOMECHANICS, 1999, 32 (03) :239-247
[28]   Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head [J].
Scholes, S. C. ;
Inman, I. A. ;
Unsworth, A. ;
Jones, E. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H3) :273-283
[29]   The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine [J].
Scholes, S. C. ;
Unsworth, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H3) :281-289
[30]   The wear performance of PEEK-OPTIMA based self-mating couples [J].
Scholes, S. C. ;
Unsworth, A. .
WEAR, 2010, 268 (3-4) :380-387