Clinical Performance of a New Hybrid Contact Lens for Keratoconus

被引:27
作者
Carracedo, Gonzalo [1 ,3 ]
Manuel Gonzalez-Meijome, Jose [2 ]
Lopes-Ferreira, Daniela [2 ]
Carballo, Jesus [1 ]
Batres, Laura [3 ]
机构
[1] Univ Complutense Madrid, Fac Opt & Optometry, Dept Opt Optometry & Vis 2, Madrid, Spain
[2] Univ Minho, Sch Sci, Ctr Phys Optometry, Clin & Expt Optometry Res Lab, Braga, Portugal
[3] Labs Lenticon SA, Madrid, Spain
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2014年 / 40卷 / 01期
关键词
Hybrid lens; Comfort; Visual outcomes; Keratoconus; QUALITY-OF-LIFE; VISUAL PERFORMANCE; SYNERGEYES; CONTRAST; ABERRATIONS; WEAR; SOFT; RELIABILITY; PIGGYBACK; COMFORT;
D O I
10.1097/ICL.0b013e3182a70ff2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives:To compare the clinical performance of the Clearkone hybrid contact lens for the treatment of keratoconus against the habitual contact lens of the patients.Methods:A total of 33 eyes from 18 patients were fitted with the Clearkone. High- and low-contrast visual acuity (HCVA and LCVA), central corneal thickness (CCT), and contrast sensitivity acuity (CSF) were recorded with habitual lenses (prestudy visit) and after 1 week, 15 days, and 1 month of wear of prescribed Clearkone. Subjective vision and comfort were rated using visual analogue scales (VAS).Results:Three patients discontinued the study, one because of diffuse corneal staining after 1 day of use and the other two because of extreme discomfort. The rest of the patients completed the 1-month study. High contrast visual acuity and LCVA (logMAR) improved significantly from 0.16 0.12 and 0.44 +/- 0.22, respectively, with the patient's habitual contact lenses to -0.006 +/- 0.058 and 0.23 +/- 0.13 after 1 day wearing Clearkone, remaining significant during all follow-up visits (P<0.001; repeated measures analysis of variance [RM-ANOVA]). There were no statistically significant differences in the mean CCT. The improvement of CSF was statistically significant with hybrid contact lenses prescribed compared with the patient's habitual contact lenses (P<0.001; RM-ANOVA test). Improvement in VAS score, with prescribed Clearkone, was statistically significant for comfort (P=0.043; RM-ANOVA test), but not for the subjective vision (P=0.759; RM-ANOVA test).Conclusions:Clearkone provides an improvement in visual acuity, contrast sensitivity, and subjective comfort in patients with keratoconus when compared with other contact lens options. However, clinicians must get specific training to fit the lens and be aware of potential adverse events.
引用
收藏
页码:2 / 6
页数:5
相关论文
共 40 条
[1]   SynergEyes Lenses for Keratoconus [J].
Abdalla, Yasmine F. ;
Elsahn, Ahmad F. ;
Hammersmith, Kristin M. ;
Cohen, Elisabeth J. .
CORNEA, 2010, 29 (01) :5-8
[2]   Effects of Contact Lenses on the Ocular Surface in Patients With Keratoconus: Piggyback Versus ClearKone Hybrid Lenses [J].
Acar, Banu Torun ;
Vural, Ece Turan ;
Acar, Suphi .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (01) :43-48
[3]  
Apsey D A, 1996, J Am Optom Assoc, V67, P151
[4]   Contact Lenses in the Management of Keratoconus [J].
Barnett, Melissa ;
Mannis, Mark J. .
CORNEA, 2011, 30 (12) :1510-1516
[5]   Visual performance and comfort with the Rose K lens for keratoconus [J].
Betts, AM ;
Mitchell, GL ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 2002, 79 (08) :493-501
[6]  
Chung Christine W., 2001, CLAO Journal, V27, P202
[7]   Is a single-item visual analogue scale as valid, reliable and responsive as multi-item scales in measuring quality of life? [J].
de Boer, AGEM ;
van Lanschot, JJB ;
Stalmeier, PFM ;
van Sandick, JW ;
Hulscher, JBF ;
de Haes, JCJM ;
Sprangers, MAG .
QUALITY OF LIFE RESEARCH, 2004, 13 (02) :311-320
[8]   Rigid contact lens fitting relationships in keratoconus [J].
Edrington, TB ;
Szczotka, LB ;
Barr, JT ;
Achtenberg, JF ;
Burger, DS ;
Janoff, AM ;
Olafsson, HE ;
Chun, MW ;
Boyle, JW ;
Gordon, MO ;
Zadnik, K .
OPTOMETRY AND VISION SCIENCE, 1999, 76 (10) :692-699
[9]   THE RELIABILITY OF THE PELLI-ROBSON CONTRAST SENSITIVITY CHART [J].
ELLIOTT, DB ;
SANDERSON, K ;
CONKEY, A .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1990, 10 (01) :21-24
[10]   Severe Epithelial Edema in Clearkone Synergeyes Contact Lens Wear for Keratoconus [J].
Fernandez-Velazquez, Fernando J. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (06) :381-385