High resolution optical coherence elastography of retina under prosthetic electrode

被引:54
作者
Li, Runze [1 ,2 ]
Du, Zhaodong [2 ]
Qian, Xuejun [1 ,2 ]
Li, Yan [3 ,4 ]
Martinez-Camarillo, Juan-Carlos [2 ]
Jiang, Laiming [2 ]
Humayun, Mark S. [1 ,2 ]
Chen, Zhongping [3 ,4 ]
Zhou, Qifa [1 ,2 ]
机构
[1] Univ Southern Calif, Dept Biomed Engn, Los Angeles, CA 90007 USA
[2] Univ Southern Calif, USC Roski Eye Inst, Los Angeles, CA 90007 USA
[3] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA USA
[4] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA USA
关键词
Optical coherence elastography; elastic wave propagation; mechanical shaker; retinal prosthetic electrode; VISUAL-PERCEPTION; LAMINA-CRIBROSA; PERFORMANCE; COMPLICATIONS; ELASTICITY; SCLERA;
D O I
10.21037/qims-20-1137
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Quantitatively investigating the biomechanics of retina with a retinal prosthetic electrode, we explored the effects of the prosthetic electrode on the retina, and further supplemented data for a potential clinical trial. Methods: Biomechanical properties were assessed with a high resolution optical coherence tomography (OCT) based elastography (OCE) system. A shaker was used to initiate elastic waves and an OCT system was used to track axial displacement along with wave propagation. Rabbits received surgery to implant the retinal prosthetic electrode, and elastic wave speed was measured before and after implantation; anatomical B-mode images were also acquired. Results: Spatial-temporal maps of each layer in retina with and without prosthetic electrodes were acquired. Elastic wave speed of nerve fiber to inner plexiform layer, inner nuclear to outer nuclear layer, retinal pigmented epithelium layer and choroid to sclera layer without prosthetic electrode were found to be 3.66 +/- 0.36, 5.33 +/- 0.07, 6.85 +/- 0.37, and 9.69 +/- 0.24 m/s, respectively. With prosthetic electrode, the elastic wave speed was found to be 4.09 +/- 0.26, 5.14 +/- 0.11, 6.88 +/- 0.70, and 9.99 +/- 0.73 m/s, respectively in each layer. Conclusions: Our results show that the elastic wave speed in each layer of retina is slightly faster with the retinal electrode, and further demonstrate that the retinal prosthetic electrode does not affect biomechanical properties significantly. In the future, we expect OCE technology to be used by clinicians where it could become part of routine testing and evaluation of the biomechanical properties of the retina in response to long term use of prosthetic electrodes in patients.
引用
收藏
页码:918 / 927
页数:10
相关论文
共 37 条
[1]   Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity [J].
Ambrozinski, Lukasz ;
Song, Shaozhen ;
Yoon, Soon Joon ;
Pelivanov, Ivan ;
Li, David ;
Gao, Liang ;
Shen, Tueng T. ;
Wang, Ruikang K. ;
O'Donnell, Matthew .
SCIENTIFIC REPORTS, 2016, 6
[2]   Evaluation of Lamina Cribrosa and Peripapillary Sclera Stiffness in Pseudoexfoliation and Normal Eyes by Atomic Force Microscopy [J].
Braunsmann, Christoph ;
Hammer, Christian M. ;
Rheinlaender, Johannes ;
Kruse, Friedrich E. ;
Schaeffer, Tilman E. ;
Schloetzer-Schrehardt, Ursula .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (06) :2960-2967
[3]   Five-Year Safety and Performance Results from the Argus II Retinal Prosthesis System Clinical Trial [J].
da Cruz, Lyndon ;
Dorn, Jessy D. ;
Humayun, Mark S. ;
Dagnelie, Gislin ;
Handa, James ;
Barale, Pierre-Olivier ;
Sahel, Jose-Alain ;
Stanga, Paulo E. ;
Hafezi, Farhad ;
Safran, Avinoam B. ;
Salzmann, Joel ;
Santos, Arturo ;
Birch, David ;
Spencer, Rand ;
Cideciyan, Artur V. ;
de Juan, Eugene ;
Duncan, Jacque L. ;
Eliott, Dean ;
Fawzi, Amani ;
de Koo, Lisa C. Olmos ;
Ho, Allen C. ;
Brown, Gary ;
Haller, Julia ;
Regillo, Carl ;
Del Priore, Lucian V. ;
Arditi, Aries ;
Greenberg, Robert J. .
OPHTHALMOLOGY, 2016, 123 (10) :2248-2254
[4]   Performance of real-world functional vision tasks by blind subjects improves after implantation with the Argus® II retinal prosthesis system [J].
Dagnelie, Gislin ;
Christopher, Punita ;
Arditi, Aries ;
da Cruz, Lyndon ;
Duncan, Jacque L. ;
Ho, Allen C. ;
de Koo, Lisa C. Olmos ;
Sahel, Jose-Alain ;
Stanga, Paulo E. ;
Thumann, Gabriele ;
Wang, Yizhong ;
Arsiero, Maura ;
Dorn, Jessy D. ;
Greenberg, Robert J. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (02) :152-159
[5]   Quantitative confocal optical coherence elastography for evaluating biomechanics of optic nerve head using Lamb wave model [J].
Du, Zhaodong ;
Li, Runze ;
Qian, Xuejun ;
Lu, Gengxi ;
Li, Yan ;
He, Youmin ;
Qu, Yueqiao ;
Jiang, Laiming ;
Chen, Zeyu ;
Humayun, Mark S. ;
Chen, Zhongping ;
Zhou, Qifa .
NEUROPHOTONICS, 2019, 6 (04)
[6]   Postoperative complications associated with 25-gauge pars plana vitrectomy [J].
Gupta, Omesh P. ;
Weichel, Eric D. ;
Regillo, Carl D. ;
Fineman, Mitchell S. ;
Kaiser, Richard S. ;
Ho, Allen C. ;
McNamara, J. Arch ;
Vander, James F. .
OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (04) :270-275
[7]   Quantitative assessment of corneal viscoelasticity using optical coherence elastography and a modified Rayleigh-Lamb equation [J].
Han, Zhaolong ;
Aglyamov, Salavat R. ;
Li, Jiasong ;
Singh, Manmohan ;
Wang, Shang ;
Vantipalli, Srilatha ;
Wu, Chen ;
Liu, Chih-hao ;
Twa, Michael D. ;
Larin, Kirill V. .
JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (02)
[8]   Retinitis pigmentosa [J].
Hartong, Dyonne T. ;
Berson, Eliot L. ;
Dryja, Thaddeus P. .
LANCET, 2006, 368 (9549) :1795-1809
[9]  
He YM, 2019, IEEE J SEL TOP QUANT, V25, DOI [10.1109/JSTQE.2018.2834435, 10.1109/jstqe.2018.2834435]
[10]   Visual perception elicited by electrical stimulation of retina in blind humans [J].
Humayun, MS ;
deJuan, E ;
Dagnelie, G ;
Greenberg, RJ ;
Prost, RH ;
Phillips, DH .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (01) :40-46