Equipment and positioning technologies in stereotactic body radiation therapy

被引:5
作者
Marchesi, V. [1 ]
Dedieu, V. [2 ]
Lacornerie, T. [3 ]
Buchheit, I. [1 ]
机构
[1] Inst Cancerol Lorraine Alexis Vautrin, Unite Phys Med, F-54519 Vandoeuvre Les Nancy, France
[2] Ctr Jean Perrin, Serv Phys Med, F-63011 Clermont Ferrand 01, France
[3] Ctr Oscar Lambret, Serv Phys Med, F-59000 Lille, France
来源
CANCER RADIOTHERAPIE | 2014年 / 18卷 / 04期
关键词
Stereotactic body radiation therapy; Technology; Positioning; Tumour tracking; GUIDED RADIOTHERAPY SYSTEM; X-RAY HEAD; FRAMELESS RADIOSURGERY; ROBOTIC RADIOSURGERY; MULTILEAF COLLIMATOR; PERFORMANCE; ACCURACY; ONCOLOGY; CANCER;
D O I
10.1016/j.canrad.2014.03.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Strereotactic body radiation therapy needs adapted or dedicated equipment to allow fulfilling the particular conditions of the stereotactic treatments: submillimetric accuracy during the treatment delivery, high doses for a reduced number of sessions. This kind of treatment can be either performed using delivery equipment conceived and dedicated to the technique, or performed on conventional machines adapted to meet the criteria. Contrary to intracranial treatments, the positioning of the target volume raises new difficulties, mainly due to the diversity of localization to treat and also due to inter- and intrafraction movements that can occur. To reduce these effects that could affect the irradiation accuracy, positioning or movement compensation, mostly due to respiration, tools have been developed. (C) 2014 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:253 / 257
页数:5
相关论文
共 30 条
[1]   Performance evaluation of a CyberKnife® G4 image-guided robotic stereotactic radiosurgery system [J].
Antypas, Christos ;
Pantelis, Evaggelos .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (17) :4697-4718
[2]   Linac-based stereotactic radiosurgery and radiotherapy [J].
Ayadi, M. ;
Ginestet, C. ;
Gassa, F. ;
Claude, L. ;
Mazeron, J. -J. .
BULLETIN DU CANCER, 2010, 97 (07) :791-806
[3]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[4]   CyberKnife® robotic stereotactic radiotherapy:: technical aspects and medical indications [J].
Bondiau, P. -Y. ;
Benezery, K. ;
Beckendorf, V. ;
Peiffert, D. ;
Gerard, J. -P ;
Mirabel, X. ;
Noel, A. ;
Marchesi, V. ;
Lacornerie, T. ;
Dubus, F. ;
Sarrazin, T. ;
Herault, J. ;
Marcie, S. ;
Angellier, G. ;
Lartigau, E. .
CANCER RADIOTHERAPIE, 2007, 11 (6-7) :338-344
[5]   Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator [J].
Chang, Zheng ;
Wang, Zhiheng ;
Wu, Q. Jackie ;
Yan, Hui ;
Bowsher, Jim ;
Zhang, Junan ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2008, 35 (10) :4460-4463
[6]   White paper on radiation oncology in France. Twelve proposals to improve a major cancer treatment [J].
Chauvet, B. ;
Mahe, M. -A. ;
Maingon, P. ;
Mazeron, J. -J. ;
Mornex, F. .
CANCER RADIOTHERAPIE, 2013, 17 :S2-S72
[7]   Is helical tomotherapy accurate and safe enough for spine stereotactic body radiotherapy? [J].
Chung, Yoonsun ;
Yoon, Hong In ;
Kim, Joo Ho ;
Nam, Ki Chang ;
Koom, Woong Sub .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2013, 139 (02) :243-248
[8]   Robotic whole body stereotactic radiosurgery:: clinical advantages of the CyberKnife® integrated system [J].
Coste-Manière, É ;
Olender, D ;
Kilby, W ;
Schulz, RA .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (02) :28-39
[9]   Geometric accuracy of a novel gimbals based radiation therapy tumor tracking system [J].
Depuydt, Tom ;
Verellen, Dirk ;
Haas, Olivier ;
Gevaert, Thierry ;
Linthout, Nadine ;
Duchateau, Michael ;
Tournel, Koen ;
Reynders, Truus ;
Leysen, Katrien ;
Hoogeman, Mischa ;
Storme, Guy ;
De Ridder, Mark .
RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) :365-372
[10]  
Derreumaux S, 2008, MESURE DOSE ABSORBEE