An initial investigation of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy

被引:57
作者
Chen, SC [1 ]
Rex, DK [1 ]
机构
[1] Indiana Univ, Sch Med, Div Gastroenterol, Dept Med, Indianapolis, IN 46204 USA
关键词
D O I
10.1111/j.1572-0241.2004.03279.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: Bispectral (BIS) monitoring has been used to evaluate depth of sedation in intensive care and surgical patients. We sought to explore its utility as a monitoring device for nurse-administered propofol sedation (NAPS) during colonoscopy. METHODS: Fifty consecutive patients (ASA I or 11) receiving NAPS for outpatient colonoscopy were evaluated. BIS scores, sedation scores, and propofol dosing were correlated. The nurses assessed the usefulness of BIS by questionnaire. RESULTS: The mean (SD) dose of propofol required to produce a BIS value < 60 was 109.4 (43.9) mg and an Observer's Assessment of Alertness/Sedation (OAA/S) score of 1 (deep sedation) was 91.4 (44.8) mg (p < 0.0001). The mean times required to achieve BIS values < 60 (188 +/- 147.1 s) and < 70 (164.3 +/- 95.1 s) were significantly longer than the mean time required to achieve an OAA/S of 1 (117.4 +/- 93.0 s, p = 0.0007). Similarly, during the recovery phase, there was a lag time of 197.9 s between mean (SD) time required from the last dose of propofol to an OAA/S of 5 (372.1 197.1 s) and the mean (SD) time required from the last dose of propofol to a BIS value greater than or equal to 90 or return to baseline (570 +/- 279.9 s, p < 0.0001). The mean (SD) BIS value in the maintenance phase of sedation was 58.9 (8.53), with a range of 22-88. Nurses administering propofol rated the usefulness of BIS at a mean of 2.85 (maximum usefulness scored as 4) in guiding the dosing of propofol sedation during the maintenance phase of sedation. No patient required mask ventilation or endotracheal intubation. CONCLUSIONS: The BIS index in its current version is not useful in titrating boluses of propofol to an adequate level of sedation, because there is a substantial lag time between decrease of BIS scores to <70 and OAA/S scores indicative of deep sedation. There is also a substantial lag time between recovery of alertness and return of BIS scores to normal. A controlled trial of whether BIS values can assist in avoiding unnecessary propofol dosing during the maintenance phase of sedation appears warranted.
引用
收藏
页码:1081 / 1086
页数:6
相关论文
共 16 条
[1]   Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery [J].
Ahmad, S ;
Yilmaz, M ;
Marcus, RJ ;
Glisson, S ;
Kinsella, A .
ANESTHESIOLOGY, 2003, 98 (04) :849-852
[2]   Bispectral index monitoring of sedation during endoscopy [J].
Bower, AL ;
Ripepi, A ;
Dilger, J ;
Boparai, N ;
Brody, FJ ;
Ponsky, JL .
GASTROINTESTINAL ENDOSCOPY, 2000, 52 (02) :192-196
[3]   Monitoring depth of anesthesia - With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall [J].
Drummond, JC .
ANESTHESIOLOGY, 2000, 93 (03) :876-882
[4]   Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness [J].
Gajraj, RJ ;
Doi, M ;
Mantzaridis, H ;
Kenny, GNC .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) :46-52
[5]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[6]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[7]   Conscious sedation with propofol in elderly patients: a prospective evaluation [J].
Heuss, LT ;
Schnieper, P ;
Drewe, J ;
Pflimlin, E ;
Beglinger, C .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2003, 17 (12) :1493-1501
[8]   Development and clinical application of electroencephalographic bispectrum monitoring [J].
Johansen, JW ;
Sebel, PS .
ANESTHESIOLOGY, 2000, 93 (05) :1336-1344
[9]   Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis [J].
Kearse, LA ;
Rosow, C ;
Zaslavsky, A ;
Connors, P ;
Dershwitz, M ;
Denman, W .
ANESTHESIOLOGY, 1998, 88 (01) :25-34
[10]  
Koshy G, 2000, AM J GASTROENTEROL, V95, P1476