An initial investigation of bispectral monitoring as an adjunct to nurse-administered propofol sedation for colonoscopy

被引:57
作者
Chen, SC [1 ]
Rex, DK [1 ]
机构
[1] Indiana Univ, Sch Med, Div Gastroenterol, Dept Med, Indianapolis, IN 46204 USA
关键词
D O I
10.1111/j.1572-0241.2004.03279.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND AND AIMS: Bispectral (BIS) monitoring has been used to evaluate depth of sedation in intensive care and surgical patients. We sought to explore its utility as a monitoring device for nurse-administered propofol sedation (NAPS) during colonoscopy. METHODS: Fifty consecutive patients (ASA I or 11) receiving NAPS for outpatient colonoscopy were evaluated. BIS scores, sedation scores, and propofol dosing were correlated. The nurses assessed the usefulness of BIS by questionnaire. RESULTS: The mean (SD) dose of propofol required to produce a BIS value < 60 was 109.4 (43.9) mg and an Observer's Assessment of Alertness/Sedation (OAA/S) score of 1 (deep sedation) was 91.4 (44.8) mg (p < 0.0001). The mean times required to achieve BIS values < 60 (188 +/- 147.1 s) and < 70 (164.3 +/- 95.1 s) were significantly longer than the mean time required to achieve an OAA/S of 1 (117.4 +/- 93.0 s, p = 0.0007). Similarly, during the recovery phase, there was a lag time of 197.9 s between mean (SD) time required from the last dose of propofol to an OAA/S of 5 (372.1 197.1 s) and the mean (SD) time required from the last dose of propofol to a BIS value greater than or equal to 90 or return to baseline (570 +/- 279.9 s, p < 0.0001). The mean (SD) BIS value in the maintenance phase of sedation was 58.9 (8.53), with a range of 22-88. Nurses administering propofol rated the usefulness of BIS at a mean of 2.85 (maximum usefulness scored as 4) in guiding the dosing of propofol sedation during the maintenance phase of sedation. No patient required mask ventilation or endotracheal intubation. CONCLUSIONS: The BIS index in its current version is not useful in titrating boluses of propofol to an adequate level of sedation, because there is a substantial lag time between decrease of BIS scores to <70 and OAA/S scores indicative of deep sedation. There is also a substantial lag time between recovery of alertness and return of BIS scores to normal. A controlled trial of whether BIS values can assist in avoiding unnecessary propofol dosing during the maintenance phase of sedation appears warranted.
引用
收藏
页码:1081 / 1086
页数:6
相关论文
共 16 条
  • [1] Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery
    Ahmad, S
    Yilmaz, M
    Marcus, RJ
    Glisson, S
    Kinsella, A
    [J]. ANESTHESIOLOGY, 2003, 98 (04) : 849 - 852
  • [2] Bispectral index monitoring of sedation during endoscopy
    Bower, AL
    Ripepi, A
    Dilger, J
    Boparai, N
    Brody, FJ
    Ponsky, JL
    [J]. GASTROINTESTINAL ENDOSCOPY, 2000, 52 (02) : 192 - 196
  • [3] Monitoring depth of anesthesia - With emphasis on the application of the bispectral index and the middle latency auditory evoked response to the prevention of recall
    Drummond, JC
    [J]. ANESTHESIOLOGY, 2000, 93 (03) : 876 - 882
  • [4] Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness
    Gajraj, RJ
    Doi, M
    Mantzaridis, H
    Kenny, GNC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (01) : 46 - 52
  • [5] Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia
    Gan, TJ
    Glass, PS
    Windsor, A
    Payne, F
    Rosow, C
    Sebel, P
    Manberg, P
    Howell, S
    Sanderson, I
    Ray, J
    Elidrissi, C
    Wilkes, N
    Calhoun, P
    Connors, P
    Alfille, P
    Shapiro, L
    Denman, W
    Dershwitz, M
    Clifford, J
    Embree, P
    Sigl, J
    [J]. ANESTHESIOLOGY, 1997, 87 (04) : 808 - 815
  • [6] Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers
    Glass, PS
    Bloom, M
    Kearse, L
    Rosow, C
    Sebel, P
    Manberg, P
    [J]. ANESTHESIOLOGY, 1997, 86 (04) : 836 - 847
  • [7] Conscious sedation with propofol in elderly patients: a prospective evaluation
    Heuss, LT
    Schnieper, P
    Drewe, J
    Pflimlin, E
    Beglinger, C
    [J]. ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2003, 17 (12) : 1493 - 1501
  • [8] Development and clinical application of electroencephalographic bispectrum monitoring
    Johansen, JW
    Sebel, PS
    [J]. ANESTHESIOLOGY, 2000, 93 (05) : 1336 - 1344
  • [9] Bispectral analysis of the electroencephalogram predicts conscious processing of information during propofol sedation and hypnosis
    Kearse, LA
    Rosow, C
    Zaslavsky, A
    Connors, P
    Dershwitz, M
    Denman, W
    [J]. ANESTHESIOLOGY, 1998, 88 (01) : 25 - 34
  • [10] Koshy G, 2000, AM J GASTROENTEROL, V95, P1476