Interference between Active Implanted Medical Devices and Electromagnetic Field Emitting Devices is Rare but Real: Results of an Incidence Study in a Population of Physicians in France

被引:19
作者
Hours, Martine [1 ,2 ,3 ]
Khati, Ines [1 ,2 ,3 ]
Hamelin, Joel [4 ]
机构
[1] Lyon Univ, Lyon, France
[2] Univ Lyon 1, UMRESTTE, F-69365 Lyon, France
[3] UMRESTTE, IFSTTAR, Bron, France
[4] Ctr Strateg Anal, Paris, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2014年 / 37卷 / 03期
关键词
active implanted medical devices; medical survey; adverse effects; electromagnetic fields; electromagnetic interference; equipment failure; postal questionnaire; security systems; mobile phones; ARTICLE SURVEILLANCE SYSTEMS; PLAYERS CAUSE INTERFERENCE; CARDIAC DEVICES; DEFIBRILLATOR; PACEMAKERS;
D O I
10.1111/pace.12269
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and ObjectiveAssessing the behavior of active implanted medical devices (AIMDs) in response to electromagnetic field (EMF) transmitters is a current issue of great importance. Given the numerous telecommunication systems and our lack of knowledge as to the impact of electromagnetic effects, this study investigated the reality of possible AIMD disturbance by EMFs by interviewing health professionals. MethodA self-administered postal questionnaire was sent to almost 5,000 physicians in five specialties: cardiology; endocrinology; ears, nose, and throat; urology; and neurology. It collected data on the existence and annual number of incidents observed and the conditions under which they occurred, the EMF sources involved, and the means of managing the malfunctions. ResultsA total of 1,188 physicians agreed to participate. Sixteen percent of participants reported cases of implant failure, three-quarters of whom, mainly in cardiology, reported rates of at least one incident per yearamounting to more than 100 incidents per year in all. Severity appeared to be moderate (discomfort or transient symptoms), but frequently required resetting or, more rarely, replacing the device. Some serious incidents were, however, reported. The sources implicated were basically of two types: electronic security systems (antitheft and airport gates) and medical electromagnetic radiation devices. These incidents were poorly reported within the public health system, preventing follow-up and effective performance of alert and surveillance functions. ConclusionAlthough minor, the risk of interference between EMF sources and AIMDs is real and calls for vigilance. It particularly concerns antitheft and airport security gates, though other sources may also cause incidents.
引用
收藏
页码:290 / 296
页数:7
相关论文
共 28 条
[1]   Implantable cardioverter defibrillator dysfunction during and after magnetic resonance imaging [J].
Anfinsen, OG ;
Berntsen, RF ;
Aass, H ;
Kongsgaard, E ;
Amlie, JP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (09) :1400-1402
[3]  
[Anonymous], 2006, Health Devices, V35, P449
[4]   Low frequency magnetic emissions and resulting induced voltages in a pacemaker by iPod portable music players [J].
Bassen, Howard .
BIOMEDICAL ENGINEERING ONLINE, 2008, 7 (1)
[5]   Intermittent, erratic behaviour of an implantable cardioverter defibrillator secondary to a hidden magnetic source of interference [J].
Beinart, Roy ;
Guy, Mary L. ;
Ellinor, Patrick T. .
EUROPACE, 2011, 13 (10) :1508-1509
[6]   A Prospective Pediatric Clinical Trial of Digital Music Players: Do They Interfere with Pacemakers? [J].
Chiu, Christine C. ;
Huh, June ;
De Souza, Laura ;
Alfaro-Ramirez, Armando ;
Clegg, Robin ;
Fenwick, Laura ;
Hamilton, Robert M. ;
Kirsh, Joel A. ;
Gross, Gil J. ;
Gao, Dongsheng ;
Stephenson, Elizabeth A. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (01) :44-49
[7]  
Colavolpe J, 2007, ANESTHESIE REANIMA B, VB-10, P336
[8]   Cochlear implant magnet displacement during magnetic resonance imaging [J].
Deneuve, Sophie ;
Loundon, Nathalie ;
Leboulanger, Nicolas ;
Rouillon, Isabelle ;
Garabedian, Erea Noel .
OTOLOGY & NEUROTOLOGY, 2008, 29 (06) :789-790
[9]  
Di Donato P., 2005, INTERACTIONS ACTIVE
[10]  
Frank R, 2003, ARCH MAL COEUR VAISS, V96, P46