Ultralow dose computed tomography protocol for hook-wire localization of solitary pulmonary nodules prior to video-assisted thoracoscopic surgery

被引:8
作者
Liu, Bo [1 ]
Fang, Jie [2 ]
Jia, Haipeng [1 ]
Sun, Zhigang [3 ]
Liao, Jian [4 ]
Meng, Hong [1 ]
Pan, Fengmin [1 ]
Li, Chunhai [1 ]
机构
[1] Shandong Univ, Dept Radiol, Qilu Hosp, Wenhua Xi Rd 107, Jinan, Shandong, Peoples R China
[2] Dezhou Peoples Hosp, Dept Resp Med, Dezhou, Peoples R China
[3] Shandong Univ, Jinan Cent Hosp, Dept Thorac Surg, Jinan, Shandong, Peoples R China
[4] Xiamen Hosp Tradit Chinese Med, Dept Radiol, Xiamen, Fujian, Peoples R China
关键词
Ultralow dose; hook-wire; localization; pulmonary nodule; VATS; GUIDED INTERVENTION; CT; SAFETY; FEASIBILITY; REDUCTION;
D O I
10.1111/1759-7714.13075
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background This study prospectively investigated the efficacy and radiation dose of ultralow dose computed tomography (CT)-guided hook-wire localization (HWL) at 100 kV with tin filtration (100Sn kV) for small solitary pulmonary nodules. Methods All HWL procedures were performed on a third generation dual-source CT system. Eighty-eight consecutive patients undergoing CT-guided HWL were randomly assigned to standard dose CT (Group A: n = 44; reference 110 kV and 50 mA) or ultralow dose CT (Group B: n =44; Sn-100 kV and 96 mA) protocols. The technical success rate, complications, subjective image quality, and radiation dose were compared between the groups. Results The mean volume CT dose index and total dose-length product were significantly lower in Group B compared to Group A (0.32 mGy vs. 3.2 +/- 1.1 mGy and 12.1 +/- 0.97 mGy-cm vs. 120 +/- 40.6 mGy-cm; P < 0.001). The effective dose in Group B was significantly lower than in Group A (0.17 +/- 0.01 mSv vs. 1.68 +/- 0.57 mSv, -89.8%; P < 0.001). The technical success rates were 100% for both groups. There were no significant differences in complication rates between the protocols (P > 0.05). The image quality of ultralow dose CT met the requirements for HWL procedure. Conclusion Ultralow dose CT-guided HWL of solitary pulmonary nodules performed at Sn-100 kVp spectral shaping significantly reduced the radiation dose compared to standard dose CT, with high technical success and acceptable patient safety.
引用
收藏
页码:1348 / 1354
页数:7
相关论文
共 26 条
[1]   Safety, efficacy, and feasibility of an ultra-low dose radiation protocol for CT-guided percutaneous needle biopsy of pulmonary lesions: Initial experience [J].
Adiga, S. ;
Athreya, S. .
CLINICAL RADIOLOGY, 2014, 69 (07) :709-714
[2]   Dose Reduction Strategies for Thoracic Multidetector Computed Tomography Background, Current Issues, and Recommendations [J].
Bankier, Alexander A. ;
Tack, Denis .
JOURNAL OF THORACIC IMAGING, 2010, 25 (04) :278-288
[3]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[4]   Low-dose CT of the lung: potential value of iterative reconstructions [J].
Baumueller, Stephan ;
Winklehner, Anna ;
Karlo, Christoph ;
Goetti, Robert ;
Flohr, Thomas ;
Russi, Erich W. ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2597-2606
[5]   Radiation Dose Reduction in Computed Tomography-Guided Lung Interventions using an Iterative Reconstruction Technique [J].
Chang, D. H. ;
Hiss, S. ;
Mueller, D. ;
Hellmich, M. ;
Borggrefe, J. ;
Bunck, A. C. ;
Maintz, D. ;
Hackenbroch, M. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (10) :906-914
[6]   Video-assisted thoracoscopic solitary pulmonary nodule resection after CT-guided hookwire localization: 43 cases report and literature review [J].
Chen, Sufeng ;
Zhou, Jianhua ;
Zhang, Jie ;
Hu, Hong ;
Luo, Xiaoyang ;
Zhang, Yawei ;
Chen, Haiquan .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (06) :1723-1729
[7]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[8]   Low-dose abdominal computed tomography for detection of urinary stone disease - Impact of additional spectral shaping of the X-ray beam on image quality and dose parameters [J].
Dewes, Patricia ;
Frellesen, Claudia ;
Scholtz, Jan-Erik ;
Fischer, Sebastian ;
Vogl, Thomas J. ;
Bauer, Ralf W. ;
Schulz, Boris .
EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (06) :1058-1062
[9]   Implementation of ultra-low-dose lung protocols in CT-guided lung biopsies: feasibility and safety in the clinical setting [J].
Frisch, Barbara K. ;
Slebocki, Karin ;
Mammadov, Kamal ;
Puesken, Michael ;
Becker, Ingrid ;
Maintz, David ;
Chang, De-Hua .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2017, 45 (06) :2101-2109
[10]   CT-guided hook-wire localisation prior to video-assisted thoracoscopic surgery of pulmonary lesions [J].
Gruber-Rouh, T. ;
Naguib, N. N. N. ;
Beeres, M. ;
Kleine, P. ;
Vogl, T. J. ;
Jacobi, V. ;
Alsubhi, M. ;
Nour-Eldin, N. A. .
CLINICAL RADIOLOGY, 2017, 72 (10) :898.e7-898.e11