TISSUE ELASTICITY QUANTIFICATION BYACOUSTIC RADIATION FORCE IMPULSE FOR THE ASSESSMENT OF RENAL ALLOGRAFT FUNCTION

被引:50
作者
He, Wan-Yuan [1 ,2 ]
Jin, Yun-Jie [1 ,2 ]
Wang, Wen-Ping [1 ]
Li, Chao-Lun [1 ]
Ji, Zheng-Biao [1 ]
Yang, Cheng [3 ,4 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Ultrasound, Shanghai 200032, Peoples R China
[2] Shanghai Inst Imaging Med, Shanghai, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Urol, Shanghai 200032, Peoples R China
[4] Shanghai Key Lab Organ Transplantat, Shanghai, Peoples R China
关键词
Acoustic radiation force impulse; Elastography; Renal transplantation; Non-invasive diagnosis; RESISTANCE INDEX; TRANSIENT ELASTOGRAPHY; LIVER FIBROSIS; KIDNEY; RECIPIENTS;
D O I
10.1016/j.ultrasmedbio.2013.10.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force impulse (ARFI) quantification, a novel ultrasound-based elastography method, has been used to measure liver fibrosis. However, few studies have been performed on the use of ARFI quantification in kidney examinations. We evaluated renal allograft stiffness using ARFI quantification in patients with stable renal function (n = 52) and those with biopsy-proven allograft dysfunction (n = 50). ARFI quantification, given as shear wave velocity (SWV), was performed. The resistance index (RI) was calculated by pulsed-wave Doppler ultrasound, and clinical and laboratory data were collected. Morphologic changes in transplanted kidneys were diagnosed by an independent pathologist. Mean SWV was more significantly negatively correlated with estimated glomerular filtration rate (eGFR) (r = -0.657, p < 0.0001) than was RI (r = -0.429, p = 0.0004) in transplanted kidneys. Receiver operating characteristic curve analysis revealed that the sensitivity and specificity of quantitative ultrasound in the diagnosis of renal allograft dysfunction were 72.0% and 86.5% (cutoff value = 2.625), respectively. The latter values were better than those of RI, which were 62.0% and 69.2% (cutoff value = 0.625), respectively. The coefficient of variation for repeat SWV measurements of the middle part of transplanted kidney was 8.64%, and inter-observer agreement on SWV was good (Bland-Altman method, ICC = 0.890). In conclusion, tissue elasticity quantification by ARFI is more accurate than the RI in diagnosing renal allograft function. (E-mail: puguang61@126.com) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 50 条
  • [41] Elasticity of healthy Achilles tendon decreases with the increase of age as determined by acoustic radiation force impulse imaging
    Ruan, Zhengmin
    Zhao, Bin
    Qi, Hengtao
    Zhang, Yuan
    Zhang, Feixue
    Wu, Mei
    Shao, Guangrui
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (01): : 1043 - 1050
  • [42] Renal shear wave velocity by acoustic radiation force impulse did not reflect advanced renal impairment
    Takata, Tomoaki
    Koda, Masahiko
    Sugihara, Takaaki
    Sugihara, Shinobu
    Okamoto, Toshiaki
    Miyoshi, Kenichi
    Matono, Tomomitsu
    Hosho, Keiko
    Mae, Yukari
    Iyama, Takuji
    Fukui, Takeaki
    Fukuda, Satoko
    Munemura, Chishio
    Isomoto, Hajime
    [J]. NEPHROLOGY, 2016, 21 (12) : 1056 - 1062
  • [43] Acoustic radiation force impulse-imaging in the assessment of liver fibrosis in children
    Noruegas, Maria Jose
    Matos, Hugo
    Goncalves, Isabel
    Cipriano, Maria Augusta
    Sanches, Conceicao
    [J]. PEDIATRIC RADIOLOGY, 2012, 42 (02) : 201 - 204
  • [44] Diagnostic Value of Acoustic Radiation Force Impulse Quantification in the Differentiation of Benign and Malignant Thyroid Nodules
    Pandey, Niraj Nirmal
    Pradhan, Gaurav Shanker
    Manchanda, Alpana
    Garg, Anju
    [J]. ULTRASONIC IMAGING, 2017, 39 (05) : 326 - 336
  • [45] Non-invasive assessment of renal allograft fibrosis by dynamic sonographic tissue perfusion measurement
    Syversveen, Trygve
    Brabrand, Knut
    Midtvedt, Karsten
    Strom, Erik H.
    Hartmann, Anders
    Berstad, Audun Elnaes
    [J]. ACTA RADIOLOGICA, 2011, 52 (08) : 920 - 926
  • [46] Combination of elastography and tissue quantification using the acoustic radiation force impulse (ARFI) technology for differential diagnosis of breast masses
    Tozaki, Mitsuhiro
    Isobe, Sachiko
    Sakamoto, Masaaki
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (08) : 659 - 670
  • [47] Combination of elastography and tissue quantification using the acoustic radiation force impulse (ARFI) technology for differential diagnosis of breast masses
    Mitsuhiro Tozaki
    Sachiko Isobe
    Masaaki Sakamoto
    [J]. Japanese Journal of Radiology, 2012, 30 : 659 - 670
  • [48] Application of acoustic radiation force impulse imaging for the evaluation of focal liver lesion elasticity
    Zhang, Ping
    Zhou, Ping
    Tian, Shuang-Ming
    Qian, Ying
    Deng, Jin
    Zhang, Lu
    [J]. HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2013, 12 (02) : 165 - 170
  • [49] Acoustic radiation force impulse imaging for non-invasive assessment of liver fibrosis in chronic hepatitis B
    Friedrich-Rust, M.
    Buggisch, P.
    de Knegt, R. J.
    Dries, V.
    Shi, Y.
    Matschenz, K.
    Schneider, M. D.
    Herrmann, E.
    Petersen, J.
    Schulze, F.
    Zeuzem, S.
    Sarrazin, C.
    [J]. JOURNAL OF VIRAL HEPATITIS, 2013, 20 (04) : 240 - 247
  • [50] ACOUSTIC RADIATION FORCE IMPULSE IMAGING WITH VIRTUAL TOUCH TISSUE QUANTIFICATION: MEASUREMENTS OF NORMAL BREAST TISSUE AND DEPENDENCE ON THE DEGREE OF PRE-COMPRESSION
    Wojcinski, Sebastian
    Brandhorst, Kathrin
    Sadigh, Gelareh
    Hillemanns, Peter
    Degenhardt, Friedrich
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (12) : 2226 - 2232