TISSUE ELASTICITY QUANTIFICATION BYACOUSTIC RADIATION FORCE IMPULSE FOR THE ASSESSMENT OF RENAL ALLOGRAFT FUNCTION

被引:50
|
作者
He, Wan-Yuan [1 ,2 ]
Jin, Yun-Jie [1 ,2 ]
Wang, Wen-Ping [1 ]
Li, Chao-Lun [1 ]
Ji, Zheng-Biao [1 ]
Yang, Cheng [3 ,4 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Ultrasound, Shanghai 200032, Peoples R China
[2] Shanghai Inst Imaging Med, Shanghai, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Urol, Shanghai 200032, Peoples R China
[4] Shanghai Key Lab Organ Transplantat, Shanghai, Peoples R China
关键词
Acoustic radiation force impulse; Elastography; Renal transplantation; Non-invasive diagnosis; RESISTANCE INDEX; TRANSIENT ELASTOGRAPHY; LIVER FIBROSIS; KIDNEY; RECIPIENTS;
D O I
10.1016/j.ultrasmedbio.2013.10.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force impulse (ARFI) quantification, a novel ultrasound-based elastography method, has been used to measure liver fibrosis. However, few studies have been performed on the use of ARFI quantification in kidney examinations. We evaluated renal allograft stiffness using ARFI quantification in patients with stable renal function (n = 52) and those with biopsy-proven allograft dysfunction (n = 50). ARFI quantification, given as shear wave velocity (SWV), was performed. The resistance index (RI) was calculated by pulsed-wave Doppler ultrasound, and clinical and laboratory data were collected. Morphologic changes in transplanted kidneys were diagnosed by an independent pathologist. Mean SWV was more significantly negatively correlated with estimated glomerular filtration rate (eGFR) (r = -0.657, p < 0.0001) than was RI (r = -0.429, p = 0.0004) in transplanted kidneys. Receiver operating characteristic curve analysis revealed that the sensitivity and specificity of quantitative ultrasound in the diagnosis of renal allograft dysfunction were 72.0% and 86.5% (cutoff value = 2.625), respectively. The latter values were better than those of RI, which were 62.0% and 69.2% (cutoff value = 0.625), respectively. The coefficient of variation for repeat SWV measurements of the middle part of transplanted kidney was 8.64%, and inter-observer agreement on SWV was good (Bland-Altman method, ICC = 0.890). In conclusion, tissue elasticity quantification by ARFI is more accurate than the RI in diagnosing renal allograft function. (E-mail: puguang61@126.com) (C) 2014 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:322 / 329
页数:8
相关论文
共 50 条
  • [11] Evaluation of Renal Parenchyma Elasticity With Acoustic Radiation Force Impulse Quantification in Nutcracker Syndrome and Comparisons With Grayscale Doppler Sonography and Laboratory Findings
    Bekci, Tumay
    Bilgici, Meltem Ceyhan
    Genc, Gurkan
    Tekcan, Demet
    Polat, Ahmet Veysel
    Tomak, Leman
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (01) : 61 - 67
  • [12] Tissue elasticity estimated by acoustic radiation force impulse quantification depends on the applied transducer force: an experimental study in kidney transplant patients
    Syversveen, Trygve
    Midtvedt, Karsten
    Berstad, Audun E.
    Brabrand, Knut
    Strom, Erik H.
    Abildgaard, Andreas
    EUROPEAN RADIOLOGY, 2012, 22 (10) : 2130 - 2137
  • [13] Acoustic Radiation Force Impulse Imaging for Noninvasive Evaluation of Renal Parenchyma Elasticity: Preliminary Findings
    Guo, Le-Hang
    Xu, Hui-Xiong
    Fu, Hui-Jun
    Peng, Ai
    Zhang, Yi-Feng
    Liu, Lin-Na
    PLOS ONE, 2013, 8 (07):
  • [14] Reliable Measurement Procedure of Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging
    Kaminuma, Chie
    Tsushima, Yoshito
    Matsumoto, Noriko
    Kurabayashi, Takemi
    Taketomi-Takahashi, Ayako
    Endo, Keigo
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (06) : 745 - 751
  • [15] Acoustic Radiation Force Impulse Quantification in the Evaluation of Thyroid Elasticity in Pediatric Patients With Hashimoto Thyroiditis
    Yucel, Serap
    Bilgici, Meltem Ceyhan
    Kara, Cengiz
    Yilmaz, Gulay Can
    Aydin, H. Murat
    Elmali, Muzaffer
    Tomak, Leman
    Saglam, Dilek
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (05) : 1143 - 1149
  • [16] Evaluation of Pancreatic Fibrosis With Acoustic Radiation Force Impulse Imaging and Automated Quantification of Pancreatic Tissue Components
    Fujita, Yusuke
    Kitago, Minoru
    Abe, Tokiya
    Itano, Osamu
    Shinoda, Masahiro
    Abe, Yuta
    Yagi, Hiroshi
    Hibi, Taizo
    Ishii, Masatsugu
    Nakano, Yutaka
    Okuma, Kiyoshi
    Hashimoto, Masahiro
    Takeuchi, Ayano
    Masugi, Yohei
    Jinzaki, Masahiro
    Sakamoto, Michiie
    Kitagawa, Yuko
    PANCREAS, 2018, 47 (10) : 1277 - 1282
  • [17] Reliable Measurement by Virtual Touch Tissue Quantification With Acoustic Radiation Force Impulse Imaging Phantom Study
    Yamanaka, Noriko
    Kaminuma, Chie
    Taketomi-Takahashi, Ayako
    Tsushima, Yoshito
    JOURNAL OF ULTRASOUND IN MEDICINE, 2012, 31 (08) : 1239 - 1244
  • [18] Preliminary study of ultrasonographic tissue quantification of the breast using the acoustic radiation force impulse (ARFI) technology
    Tozaki, Mitsuhiro
    Isobe, Sachiko
    Fukuma, Eisuke
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (02) : E182 - E187
  • [19] Acoustic Radiation Force Impulse Elastography Assessment of Lymphoedema Tissue: An Insight into Tissue Stiffness
    Sanderson, Jennifer
    Tuttle, Neil
    Laakso, Liisa
    CANCERS, 2022, 14 (21)
  • [20] Thyroid Stiffness Assessment by Acoustic Radiation Force Impulse Elastography (ARFI)
    Sporea, I.
    Vlad, M.
    Bota, S.
    Sirli, R. L.
    Popescu, A.
    Danila, M.
    Sendroiu, M.
    Zosin, I.
    ULTRASCHALL IN DER MEDIZIN, 2011, 32 (03): : 281 - 285