Real-time hemodynamic response and mitochondrial function changes with intracarotid mannitol injection

被引:6
作者
Joshi, Shailendra [1 ]
Singh-Moon, Rajinder [1 ]
Wang, Mei [1 ]
Bruce, Jeffrey N. [2 ]
Bigio, Irving J. [3 ]
Mayevsky, Auraham [4 ]
机构
[1] Columbia Univ, Coll Phys & Surg, Dept Anesthesiol, New York, NY 10032 USA
[2] Columbia Univ, Coll Phys & Surg, Dept Neurol Surg, New York, NY 10032 USA
[3] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
[4] Bar Ilan Univ, Fac Life Sci, IL-52900 Ramat Gan, Israel
关键词
Ischemia; Intracarotid; Nicotinamide adenine dinucleotide; Blood brain barrier; Mannitol; Intraarterial chemotherapy; Ultraviolet spectroscopy; BLOOD-BRAIN-BARRIER; TRANSIENT CEREBRAL HYPOPERFUSION; OXYGEN-CONSUMPTION; REDOX CHANGES; DISRUPTION; INFUSION; DELIVERY; FLOW; QUANTIFICATION; FLUORESCENCE;
D O I
10.1016/j.brainres.2013.12.036
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Disruption of blood brain barrier (BBB) is used to enhance chemotherapeutic drug delivery. The purpose of this study was to understand the time course of hemodynamic and metabolic response to intraarterial (IA) mannitol infusions in order to optimize the delivery of drugs for treating brain tumors. Principal results: We compared hemodynamic response, EEG changes, and mitochondrial function as judged by relative changes in tissue NADH concentrations, after intracarotid (IC) infusion of equal volumes of normal saline and mannitol in our rabbit IC drug delivery model. We observed significantly greater, though transient, hyperemic response to IC infusion of mannitol compared to normal saline. Infusion of mannitol also resulted in a greater increase in tissue NADH concentrations relative to the baseline. These hemodynamic, and metabolic changes returned to baseline within 5 min of mannitol injection. Conclusion: Significant, though transient, changes in blood flow and brain metabolism occur with IA mannitol infusion. The observed transient hyperemia would suggest that intravenous (IV) chemotherapy should be administered either just before, or concurrent with IA mannitol injections. On the other hand, IA chemotherapy should be delayed until the peak hyperemic response has subsided. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 51
页数:10
相关论文
共 50 条
[41]   BACTERIA COMMUNITY ANALYSIS BY QUANTITATIVE REAL-TIME PCR OF FERMENTING WAX GOURD AND ITS CHANGES OF ORGANIC ACIDS [J].
Zhao, Y. W. ;
Wu, Z. F. ;
Shen, X. Q. ;
Weng, P. F. ;
Chen, J. J. .
JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2014, 38 (04) :1653-1659
[42]   Standardized Rat Coronary Ring Preparation and Real-Time Recording of Dynamic Tension Changes Along Vessel Diameter [J].
Guo, Pengmei ;
An, Wenqiao ;
Guo, Ying ;
Sun, Zhihao ;
Wang, Xiaobo ;
Zhang, Sanyin .
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (184)
[43]   Contrast-Based Real-Time Assessment of Microcirculatory Changes in a Fatty Liver After Ischemia Reperfusion Injury [J].
Kolachala, Vasantha L. ;
Jiang, Rong ;
Abramowsky, Carlos R. ;
Gupta, Nitika A. .
JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2016, 62 (03) :429-436
[44]   A facile combinatorial approach to construct a ratiometric fluorescent sensor: application for the real-time sensing of cellular pH changes [J].
Nakata, Eiji ;
Hirose, Hisaaki ;
Gerelbaatar, Khongorzul ;
Arafiles, Jan Vincent V. ;
Zhang, Zhengxiao ;
Futaki, Shiroh ;
Morii, Takashi .
CHEMICAL SCIENCE, 2021, 12 (23) :8231-8240
[45]   Real-Time, Digital LAMP with Commercial Microfluidic Chips Reveals the Interplay of Efficiency, Speed, and Background Amplification as a Function of Reaction Temperature and Time [J].
Rolando, Justin C. ;
Jue, Erik ;
Schoepp, Nathan G. ;
Ismagilov, Rustem F. .
ANALYTICAL CHEMISTRY, 2019, 91 (01) :1034-1042
[46]   Assessment of the morphology and mechanical function of the left atrial appendage by real-time three-dimensional transesophageal echocardiography [J].
Chen Ou-di ;
Wu Wei-chun ;
Jiang Yong ;
Xiao Ming-hu ;
Wang Hao .
CHINESE MEDICAL JOURNAL, 2012, 125 (19) :3416-3420
[47]   Metabolism of hyperpolarized 13C-acetoacetate to β-hydroxybutyrate detects real-time mitochondrial redox state and dysfunction in heart tissue [J].
Chen, Wei ;
Sharma, Gaurav ;
Jiang, Weina ;
Maptue, Nesmine R. ;
Malloy, Craig R. ;
Sherry, A. Dean ;
Khemtong, Chalermchai .
NMR IN BIOMEDICINE, 2019, 32 (06)
[48]   The value of real-time myocardial contrast echocardiography for detecting coronary microcirculation function in coronary artery disease patients [J].
Sun, Lulu ;
Wang, Zilong ;
Xu, Tongda ;
Pan, Defeng ;
Liang, Li ;
Hao, Ji ;
Wang, Xiaoping ;
Li, Dongye .
ANATOLIAN JOURNAL OF CARDIOLOGY, 2018, 19 (01) :27-33
[49]   The utility of fully automated real-time three-dimensional echocardiography in the evaluation of left ventricular diastolic function [J].
Nakanishi, Koki ;
Fukuda, Shota ;
Watanabe, Hiroyuki ;
Seo, Yoshihiro ;
Mahara, Keitaro ;
Hyodo, Eiichi ;
Otsuka, Kenichiro ;
Ishizu, Tomoko ;
Shimada, Kenei ;
Sumiyoshi, Tetsuya ;
Aonuma, Kazutaka ;
Tomoike, Hitonobu ;
Yoshikawa, Junichi .
JOURNAL OF CARDIOLOGY, 2015, 66 (1-2) :50-56
[50]   Continuous, Real-Time, Noninvasive Hemodynamic Cardiac Doppler Monitoring With a Novel Hands-Free Device: A Feasibility Study Compared to Standard Echo [J].
Lancaster, Gilead I. ;
Hay, Ilan ;
Eldar, Michael .
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (03)