Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source

被引:44
作者
Barnes, JH
Sperline, R
Denton, MB
Barinaga, CJ
Koppenaal, D
Young, ET
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
[2] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
[3] Pacific NW Natl Lab, Richland, WA 99352 USA
[4] Univ Arizona, Steward Observ, Tucson, AZ 85721 USA
关键词
D O I
10.1021/ac020304z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Mattauch-Herzog geometry mass spectrograph (MHMS) has been equipped with a novel array detector, the focal plane camera (FPC). The FPC consists of an array of gold Faraday cups, each coupled to its own integrator, with interrogation of the integrators performed by a multiplexer. The initial coupling of this instrument with a pin-type glow discharge source has provided limits of detection in the single to hundreds of nanograms per gram regime; isotope ratio accuracy and precision better than 5% error and 0.2% RSD, respectively; and a linear dynamic range of at least 6 orders of magnitude. A current weakness of the FPC is its pixel size, which limits both sensitivity and baseline resolution (to R =. 130). The minimum data acquisition time for multiple images at present is 1 ms/image, with a dead time of 3.2 ms between images, which will limit the ability of the FPC to monitor extremely short transient signals.
引用
收藏
页码:5327 / 5332
页数:6
相关论文
共 27 条
[1]   Atomic spectrometry update. Atomic mass spectrometry [J].
Bacon, JR ;
Crain, JS ;
Van Vaeck, L ;
Williams, JG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :879-915
[2]   Inorganic trace analysis by mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) :1475-1506
[3]   High resolution focal plane detector for a space-borne magnetic mass spectrometer [J].
Berthelier, JJ ;
Illiano, JM ;
Nevejans, D ;
Neefs, E ;
Arijs, E ;
Schoon, N .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) :89-100
[4]   Mass spectrum measurement using a one-dimensional focal plane detector [J].
Birkinshaw, K .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) :195-209
[5]  
BOETTGER HG, 1977, ADV MASS SPECTROM, V2, P513
[6]  
BRUSHWYLER KR, 1990, TALANTA, V37, P23
[7]   Design and performance of a plasma-source mass spectrograph [J].
Burgoyne, TW ;
Hieftje, GM ;
Hites, RA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (04) :307-318
[8]  
Dawson J.H.J., 1989, Rapid Commun. Mass Spectrom, V3, P155, DOI DOI 10.1002/RCM.1290030511
[9]   Active pixel sensors for mass spectrometry [J].
Fuerstenau, S ;
Soli, G ;
Cunningham, T ;
Hancock, B ;
Pain, B ;
Sinha, M .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) :101-111
[10]  
Giffin C. E., 1974, International Journal of Mass Spectrometry and Ion Physics, V15, P437, DOI 10.1016/0020-7381(74)80041-0