Applying pinch and exergy analysis for energy efficient design of diesel hydrotreating unit

被引:35
作者
Bandyopadhyay, Rajarshi [1 ,2 ]
Alkilde, Ole Frej [3 ]
Upadhyayula, Sreedevi [2 ]
机构
[1] Haldor Topsoe India Pvt Ltd, 12-3 Mathura Rd,Sect 27, Faridabad 121003, Haryana, India
[2] Indian Inst Technol Delhi, Dept Chem Engn, New Delhi 110016, India
[3] Haldor Topsoe Res Labs, Haldor Topsoes Alle 1, DK-2800 Lyngby, Denmark
关键词
Diesel hydrotreating unit (DHT); Hot separator layout; Cold separator layout; Pinch Analysis (PA); Exergy analysis; Energy efficiency; HEAT-EXCHANGER NETWORKS; POWER-PLANTS; INTEGRATION; OPTIMIZATION; SYSTEM; CYCLE; PERFORMANCE; GENERATION;
D O I
10.1016/j.jclepro.2019.05.277
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Pinch Analysis (PA) and Exergy Analysis have been used, either independently or in combination, for energy integration of process plants. This paper discusses a methodology to apply PA and Exergy Analysis during design of a new process plant to make it energy efficient, using Diesel Hydrotreating Unit (DHT) as an example. PA has been used to estimate the Minimum Energy Requirement (MER), to select utilities and to design the optimal Heat Exchanger Network (HEN). Exergy Analysis is then performed to pinpoint the sources of energy inefficiency in the whole plant and suggest improvements. The application of these two techniques has helped in energy integration of the plant during the design phase itself. Two common layouts of diesel hydrotreating unit-the 'hot separator layout' and the 'cold separator layout'-have been studied. The minimum Total Annualized Cost (TAC) is similar to 7.6 M(sic)/y and similar to 10 M(sic)/y for the hot separator layout and the cold separator layout respectively. Exergy destroyed is 27.15 MW (7.9% of exergy input) and 50.18 MW (6.7% of exergy input) respectively for the hot separator layout and the cold separator layout. Exergy Analysis reveals that the energy efficiency can be improved for air coolers, fired heaters and letdown valves. (C)2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:337 / 349
页数:13
相关论文
共 88 条
[1]   A review on exergy analysis of drying processes and systems [J].
Aghbashlo, Mortaza ;
Mobli, Hossein ;
Rafiee, Shahin ;
Madadlou, Ashkan .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 22 :1-22
[2]   A review on exergy analysis of vapor compression refrigeration system [J].
Ahamed, J. U. ;
Saidur, R. ;
Masjuki, H. H. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (03) :1593-1600
[3]   Energy Level Composite Curves-a new graphical methodology for the integration of energy intensive processes [J].
Anantharaman, R ;
Abbas, OS ;
Gundersen, T .
APPLIED THERMAL ENGINEERING, 2006, 26 (13) :1378-1384
[4]  
[Anonymous], 2016, ORGANIC RANKINE CYCL
[5]  
[Anonymous], 2014, SIMSC ESSC PRO 2 9 2
[6]  
[Anonymous], 2007, 618 AIP
[7]   Diagnosis and redesign of power plants using combined Pinch and Exergy Analysis [J].
Arriola-Medellin, Alejandro ;
Manzanares-Papayanopoulos, Emilio ;
Romo-Millares, Cesar .
ENERGY, 2014, 72 :643-651
[8]   Energy and exergy analysis of fuel cells: A review [J].
Arshad, Adeel ;
Ali, Hafiz Muhammad ;
Habib, Arslan ;
Bashir, Muhammad Anser ;
Jabbal, Mark ;
Yan, Yuying .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2019, 9 :308-321
[9]   An Extended Pinch Analysis and Design procedure utilizing pressure based exergy for subambient cooling [J].
Aspelund, Audun ;
Berstad, David Olsson ;
Gundersen, Truls .
APPLIED THERMAL ENGINEERING, 2007, 27 (16) :2633-2649
[10]  
Ataei A, 2010, INT J PHYS SCI, V5, P1110