Study of Radially Varying Magnetic Field on Blood Flow through Catheterized Tapered Elastic Artery with Overlapping Stenosis

被引:11
作者
Nadeem, S. [1 ]
Ijaz, S. [1 ]
机构
[1] Quaid I Azam Univ 45320, Dept Math, Islamabad 44000, Pakistan
关键词
blood flow; overlapping stenosis; radially varying magnetic field; catheterized artery; metallic nanoparticles; JEFFREY FLUID; PERISTALTIC FLOW; METALLIC NANOPARTICLES; SUSPENSION; MODEL; SIMULATION;
D O I
10.1088/0253-6102/64/5/537
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A precise model has been developed for studying the influence of metallic nanoparticles on blood flow through catheterized tapered elastic arteries with radially varying magnetic field. The model is solved under the mild stenosis approximation by considering blood as viscous fluid. The influence of different flow parameters associated with this problem such as Hartmann number, nanoparticle volume fraction, Grashof number and heat source or sink parameter is analyzed by plotting the graphs of the wall shear stress, resistance impedance to blood flow and stream lines. The influence of the radially varying magnetic field on resistance impedance to flow is analyzed and it is observed that the significantly strong magnetic force tends to increase in resistance.
引用
收藏
页码:537 / 546
页数:10
相关论文
共 32 条
[1]   Peristaltic flow of a Jeffrey fluid under the effect of radially varying magnetic field in a tube with an endoscope [J].
Abd-Alla, A. M. ;
Abo-Dahab, S. M. ;
Kilicman, A. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 384 :79-86
[2]   Magnetic field effects for copper suspended nanofluid venture through a composite stenosed arteries with permeable wall [J].
Akbar, Noreen Sher ;
Butt, Adil Wahid .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 381 :285-291
[3]   Metallic Nanoparticles Analysis for the Peristaltic Flow in an Asymmetric Channel With MHD [J].
Akbar, Noreen Sher .
IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2014, 13 (02) :357-361
[4]   Simulation of Variable Viscosity and Jeffrey Fluid Model for Blood Flow Through a Tapered Artery with a Stenosis [J].
Akbar, Noreen Sher ;
Nadeem, S. .
COMMUNICATIONS IN THEORETICAL PHYSICS, 2012, 57 (01) :133-140
[5]  
[Anonymous], B MATH BIOL
[6]   A nonlinear two-dimensional model of blood flow in an overlapping arterial stenosis subjected to body acceleration [J].
Chakravarty, S ;
Mandal, PK .
MATHEMATICAL AND COMPUTER MODELLING, 1996, 24 (01) :43-58
[7]  
Choi S U S., 1995, ASEM PUBL FED, V231, P99
[8]   Estimation of increased flow resistance in a narrow catheterized artery - A theoretical model [J].
Dash, RK ;
Jayaraman, G ;
Mehta, KN .
JOURNAL OF BIOMECHANICS, 1996, 29 (07) :917-930
[9]   Blood flow of Jeffrey fluid in a catherized tapered artery with the suspension of nanoparticles [J].
Ellahi, R. ;
Rahman, S. U. ;
Nadeem, S. .
PHYSICS LETTERS A, 2014, 378 (40) :2973-2980
[10]   Series Solutions of Magnetohydrodynamic Peristaltic Flow of a Jeffrey Fluid in Eccentric Cylinders [J].
Ellahi, R. ;
Riaz, A. ;
Nadeem, S. ;
Mushtaq, M. .
APPLIED MATHEMATICS & INFORMATION SCIENCES, 2013, 7 (04) :1441-1449