The real-time dose measurement scintillating fiber array for intravascular Brachytherapy procedures

被引:0
作者
Guèye, P [1 ]
Harmon, C [1 ]
Tynes, L [1 ]
Keppel, C [1 ]
Kieper, D [1 ]
Onumah, N [1 ]
机构
[1] Hampton Univ, Dept Phys, Ctr Adv Med Applicat, Hampton, VA 23668 USA
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Intravascular Brachytherapy using catheter based high dose rate beta sources has taken nowadays an important role in interventional cardiology to combat in-stent restenosis following percutaneous transluminal coronary angioplasty. At the present time, there is no detector system which can record accurate quantitative doses and spatial information in real time for intravascular brachytherapy. This is partially because of the short-range of the low energy beta emission of (32)p (average energy of 690 keV) and Sr-90/Y-90 (average energy of 930 keV) and the resolution limitation of existing extrapolation chambers and radiochromatic-dye films (currently the preferred method used). However, relatively high non-uniformity, which occurs at the stepping region due to excessive gapping or overlapping between steps, might result in instent restenosis or detrimental to the coronary vascular structure due to significant discrepancies between prescribed and delivered doses. We have developed a Scintillating Fiber Based Beta Detector prototype which will permit: (i) extracting in real time of accurate dose measurements of the radioactive emitter in 2D or 3D; (ii) address the junction/stepping problem in a reliable fashion; (iii) allow extraction of information on the (in)homogeneity of the radioactive source (if any); and (iv) provide a quick feedback to radio-therapists for a fast re-adjustment of the radiation exposure for patient treatments. It is composed of an array of 3 x 3 mm(2) scintillating fibers optically coupled to photo-multiplier tubes for photon-to-current conversion. A CAMAC LabView based data acquisition system is used for data collection, histogramming and data analysis. A Geant4 Monte Carlo simulation was also specially developed for this detector to provide the necessary tool to investigate the various capabilities of such devices.
引用
收藏
页码:1855 / 1859
页数:5
相关论文
共 10 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE [J].
Asenjo, J ;
Fernández-Varea, JM ;
Sánchez-Reyes, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05) :697-711
[3]   Inaccuracy in manual multisegmental irradiation in coronary arteries [J].
Coen, VLMA ;
Marijnissen, JPA ;
Ligthart, JMR ;
de Pan, C ;
Drenth, J ;
den Boer, A ;
van der Giessen, WJ ;
Serruys, PW ;
Levendag, PC .
RADIOTHERAPY AND ONCOLOGY, 2002, 63 (01) :89-95
[4]  
Crocker I, 2001, J Invasive Cardiol, V13, P782
[5]  
DIAP HB, 2001, INT J RADIAT ONCOL, V49, P273
[6]  
GUEYE P, 2003, IN PRESS P AAPM C SA
[7]  
MEIGOONI R, 1995, MED PHYS, V22, P209
[8]   Dosimetry characterization of a 32P source wire used for intravascular brachytherapy with automated stepping [J].
Mourtada, F ;
Soares, CG ;
Seltzer, SM ;
Bergstrom, PM ;
Fernández-Verea, JM ;
Asenjo, J ;
Lott, SH .
MEDICAL PHYSICS, 2003, 30 (05) :959-971
[9]   Clinical and angiographic outcomes after use of 90strontium/90yttrium beta radiation for the treatment of in-stent restenosis:: Results from the Stents and Radiation Therapy 40 (START 40) Registry [J].
Suntharalingam, M ;
Laskey, W ;
Lansky, AJ ;
Waksman, R ;
White, L ;
Teirstien, P ;
Massullo, V ;
Rutherford, B ;
Elman, A ;
Kuntz, RE ;
Popma, JJ ;
Bonan, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (04) :1075-1082
[10]   Use of localised intracoronary β radiation in treatment of in-stent restenosis:: the INHIBIT randomised controlled trial [J].
Waksman, R ;
Raizner, AE ;
Yeung, AC ;
Lansky, AJ ;
Vandertie, L .
LANCET, 2002, 359 (9306) :551-557