Combined magnetic resonance imaging and optical surgical navigation system guidance of percutaneous liver cryoablation in a porcine model

被引:0
|
作者
Zhou, Kang [1 ]
Zhang, Zhuoli [2 ]
Figini, Matteo [2 ]
Shangguan, Junjie [2 ]
Wang, Yining [1 ]
Shi, Haifeng [1 ]
Li, Yumei [1 ]
Jin, Zhengyu [1 ]
Pan, Jie [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Shuaifuyuan 1, Beijing 100730, Peoples R China
[2] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
来源
AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH | 2018年 / 10卷 / 05期
关键词
Cryoablation; pig model; liver model; magnetic resonance imaging; optical surgical navigation system; image-guided; RADIOFREQUENCY ABLATION; TEMPERATURE DISTRIBUTION; HEPATIC CRYOTHERAPY; TUMORS; METASTASES; THROMBOCYTOPENIA; MRI;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The efficacy and safety of combining open-configuration magnetic resonance imaging (MRI) and an optical surgical navigation system (OSNS) for guidance of percutaneous liver cryoablation were evaluated in a pig model. This approach was successfully executed in eight test pigs under general anesthesia. Another two pigs spared from ablation served as controls. MRI studies, blood testing, and pathologic examinations were performed at various time points. MRI-determined minimal and maximal cryolesion diameters were 19.4 +/- 1.5 mm and 44.3 +/- 1.8 mm, respectively (mean volume, 8.32 +/- 2.41 cm(3)). The lesions were readily visible by MRI on postablation Days 2 and 7, all presenting as teardrop-shaped regions of low signal intensity in T1-weighted images and high signal intensity in T2-weighted images. Mean serum alanine aminotransferase concentration transiently increased postablation, and mean blood platelet count transiently declined (both, P < 0.05). The mean necrotic tissue volume generated by pathologic assessment was less than that determined by MRI (4.24 +/- 2.3 cm(3) vs. 8.32 +/- 2.41 cm(3), P < 0.05). Cell necrosis isotherms in MRI views were within 6.0 +/- 0.8 mm of cryolesion edges. Inflammatory cell infiltrates and exuberant granulation tissue surrounded necrotic areas on postablation Day 7. Combined open-configuration MRI and OSNS guidance of percutaneous liver cryoablation proved effective and safe in our animal model. This concept seems ideal for precision image-guided hepatic ablation in a clinical setting.
引用
收藏
页码:1531 / 1538
页数:8
相关论文
共 50 条
  • [1] Percutaneous renal tumor cryoablation with magnetic resonance imaging guidance
    Shingleton, WB
    Sewell, PE
    JOURNAL OF UROLOGY, 2001, 165 (03) : 773 - 776
  • [2] Percutaneous cryoablation of porcine kidneys with magnetic resonance imaging monitoring
    Shingleton, WB
    Farabaugh, P
    Hughson, M
    Sewell, PE
    JOURNAL OF UROLOGY, 2001, 166 (01) : 289 - 291
  • [3] Comparison of percutaneous cryoablation with microwave ablation in a porcine liver model
    Niu, Lizhi
    Li, Jialiang
    Zeng, Jianying
    Zhou, Liang
    Wang, Song
    Zhou, Xulong
    Sheng, Lin
    Chen, Jibing
    Xu, Kecheng
    CRYOBIOLOGY, 2014, 68 (02) : 194 - 199
  • [4] Magnetic Resonance Imaging Guidance for Percutaneous Needle Intervention
    Uka, Mayu
    Matsui, Yusuke
    Iguchi, Toshihiro
    Matsushita, Toshi
    Tomita, Koji
    Umakoshi, Noriyuki
    Kawabata, Takahiro
    Yamada, Masanori
    Hiraki, Takao
    INTERVENTIONAL RADIOLOGY, 2024, 9 (03) : 92 - 98
  • [5] Magnetic resonance guidance of percutaneous ethanol injection in liver
    Alexander, AL
    Barrette, TR
    Unger, EC
    ACADEMIC RADIOLOGY, 1996, 3 (01) : 18 - 25
  • [6] Magnetic resonance imaging findings and histopathological observations after percutaneous renal cryoablation in the rabbit model
    Zhu, Q
    Shimizu, T
    Abo, D
    Jin, ML
    Nagashima, K
    Miyasaka, K
    JOURNAL OF UROLOGY, 2006, 175 (01) : 318 - 326
  • [7] Magnetic resonance imaging-guided percutaneous cryoablation of hepatocellular carcinoma in special regions
    Wu, Bin
    Xiao, Yue-Yong
    Zhang, Xiao
    Zhang, Ai-Lian
    Li, Hong-Jun
    Gao, Deng-Fa
    HEPATOBILIARY & PANCREATIC DISEASES INTERNATIONAL, 2010, 9 (04) : 384 - 392
  • [8] Percutaneous cryoablation of small kidney tumours under magnetic resonance imaging guidance: Medium-term follow-up
    Caviezel, Alessandro
    Terraz, Sylvain
    Schmidlin, Franz
    Becker, Christoph
    Iselin, Christophe E.
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2008, 42 (05): : 412 - 416
  • [9] Magnetic resonance temperature imaging of laser-induced thermotherapy: assessment of fast sequences in ex vivo porcine liver
    Bazrafshan, Babak
    Huebner, Frank
    Farshid, Parviz
    Paul, Jijo
    Hammerstingl, Renate
    Vogel, Vitali
    Maentele, Werner
    Vogl, Thomas J.
    FUTURE ONCOLOGY, 2013, 9 (07) : 1039 - 1050