Corrosion monitoring in archives by the electrical resistance technique

被引:45
作者
Kouril, Milan [1 ]
Prosek, Tomas [2 ]
Scheffel, Bert [3 ]
Degres, Yves [4 ]
机构
[1] Inst Chem Technol, CR-16628 Prague, Czech Republic
[2] French Corros Inst, Inst Corroston, F-29200 Brest, France
[3] Fraunhofer Inst Electron Beam & Plasma Technol, D-01277 Dresden, Germany
[4] NKE Elect, F-56700 Hennebont, France
关键词
Electrical resistance; Corrosion monitoring; Indoor air quality; Archive; Corrosivity classification; ATMOSPHERIC CORROSION; MUSEUM ENVIRONMENTS; COUPONS;
D O I
10.1016/j.culher.2013.04.002
中图分类号
K85 [文物考古];
学科分类号
0601 ;
摘要
It is essential that corrosion monitoring of indoor atmospheres should be highly sensitive, especially, when corrosion rates corresponding to the lowest standard corrosivity categories are supposed to be identified within one or a few days. The electrical resistance technique in combination with high-sensitivity electrical resistance sensors enabled detection of a corrosion loss on an atomic scale. Case studies have demonstrated the sensors' ability to timely inform the users about changes in the atmosphere quality. In confrontation with quartz crystal microbalance technique, resistometric sensors provided better explainable data. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 20 条
  • [1] [Anonymous], 2006, 1184412006 ISO
  • [2] Atmospheric corrosion of historical organ pipes: The influence of environment and materials
    Chiavari, Cristina
    Martini, Carla
    Prandstraller, Daria
    Niklasson, Annika
    Johansson, Lars-Gunnar
    Svensson, Jan-Erik
    Aslund, Alf
    Bergsten, Carl Johan
    [J]. CORROSION SCIENCE, 2008, 50 (09) : 2444 - 2455
  • [3] Monitoring Copper and Silver Corrosion in Different Museum Environments by Electrical Resistance Measurement
    Dubus, Michel
    Kouril, Milan
    Nguyen, Thi-Phuong
    Prosek, Tomas
    Saheb, Mandana
    Tate, Jim
    [J]. STUDIES IN CONSERVATION, 2010, 55 (02) : 121 - 133
  • [4] A THICK-FILM SENSOR FOR ATMOSPHERIC CORROSION TESTING
    FRAIGI, L
    GWIRC, SN
    LUPI, D
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 558 - 561
  • [5] Acetic and formic acids emitted from wood samples and their effect on selected materials in museum environments
    Gibson, L. T.
    Watt, C. M.
    [J]. CORROSION SCIENCE, 2010, 52 (01) : 172 - 178
  • [6] Solid-phase microcolumn extraction and gas chromatography-mass spectrometry identification of volatile organic compounds emitted by paper
    Hrivnak, Jan
    Toelgyessy, Peter
    Figedyova, Sona
    Katuscak, Svetozar
    [J]. TALANTA, 2009, 80 (01) : 400 - 402
  • [7] Jung S., 2002, CORROS SCI TECHNOL, V31, P383
  • [8] Leygraf C., 2000, ELEC SOC S, P368
  • [9] USE OF WEIGHT-LOSS COUPONS AND ELECTRICAL-RESISTANCE PROBES IN ATMOSPHERIC CORROSION TESTS
    MCKENZIE, M
    VASSIE, PR
    [J]. BRITISH CORROSION JOURNAL, 1985, 20 (03): : 117 - 124
  • [10] Noda K., 2002, 15 INT CORR C FRONT