Measurement of time resolution of the Mu2e LYSO calorimeter prototype

被引:11
作者
Atanov, N. [1 ]
Baranov, V. [1 ]
Colao, E. [2 ]
Cordelli, M. [2 ]
Corradi, G. [2 ]
Dane, E. [2 ]
Davydov, Yu I. [1 ]
Flood, K. [3 ]
Giovannella, S. [2 ]
Glagolev, V. [1 ]
Happacher, F. [2 ]
Hitlin, D. G. [3 ]
Martini, M. [2 ,4 ]
Miscetti, S. [2 ]
Miyashita, T. [3 ]
Morescalchi, L. [5 ,6 ]
Pezzullo, G. [5 ,7 ]
Saputi, A. [2 ]
Sarra, I. [2 ]
Soleti, S. R. [2 ]
Tassielli, G. [8 ,9 ]
Tereshchenko, V. [1 ]
机构
[1] Joint Inst Nucl Res, Dubna, Russia
[2] Ist Nazl Fis Nucl, Lab Nazl Frascati, POB 13, I-00044 Frascati, Italy
[3] CALTECH, Pasadena, CA 91125 USA
[4] Univ Guglielmo Marconi, Rome, Italy
[5] Ist Nazl Fis Nucl, Pisa, Italy
[6] Univ Siena, Via Laterina 8, I-53100 Siena, Italy
[7] Univ Pisa, Pisa, Italy
[8] Ist Nazl Fis Nucl, I-73100 Lecce, Italy
[9] Univ Salento, Lecce, Italy
基金
欧盟地平线“2020”;
关键词
Calorimetry; Timing; APD; LYSO crystals; Mu2e experiment; ENERGY;
D O I
10.1016/j.nima.2015.12.055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
l In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the e-beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30 x 30 x 130 mm(3), LYSO crystals read out by 10 x 10 mm(2) Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as sigma(t)(E)= a/ root E /GeV circle plus b, with the stochastic and constant terms a =( 51 +/- 1) ps and b = (10 +/- 4) ps, respectively. This corresponds to the time resolution of (162 +/- 4) ps at 100 MeV. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 111
页数:8
相关论文
共 13 条
[1]  
Abrams R.J., 2012, Mu2e Conceptual Design Report
[2]  
Bartoszek L., 2014, MU2E TECHNICAL DESIG
[3]   A search for μ-e conversion in muonic gold [J].
Bertl, W. ;
Engfer, R. ;
Hermes, E. A. ;
Kurz, G. ;
Kozlowski, T. ;
Kuth, J. ;
Otter, G. ;
Rosenbaum, F. ;
Ryskulov, N. M. ;
van der Schaaf, A. ;
Wintz, P. ;
Zychor, I. .
EUROPEAN PHYSICAL JOURNAL C, 2006, 47 (02) :337-346
[4]  
Brun R., 1994, GEANT DETECTOR DESCR
[5]   Time reconstruction and performance of the CMS electromagnetic calorimeter [J].
Chatrchyan, S. ;
Khachatryan, V. ;
Sirunyan, A. M. ;
Adam, W. ;
Arnold, B. ;
Bergauer, H. ;
Bergauer, T. ;
Dragicevic, M. ;
Eichberger, M. ;
Eroe, J. ;
Friedl, M. ;
Fruehwirth, R. ;
Ghete, V. M. ;
Hammer, J. ;
Haensel, S. ;
Hoch, M. ;
Hoermann, N. ;
Hrubec, J. ;
Jeitler, M. ;
Kasieczka, G. ;
Kastner, K. ;
Krammer, M. ;
Liko, D. ;
de Abril, I. Magrans ;
Mikulec, I. ;
Mittermayr, F. ;
Neuherz, B. ;
Oberegger, M. ;
Padrta, M. ;
Pernicka, M. ;
Rohringer, H. ;
Schmid, S. ;
Schoefbeck, R. ;
Schreiner, T. ;
Stark, R. ;
Steininger, H. ;
Strauss, J. ;
Taurok, A. ;
Teischinger, F. ;
Themel, T. ;
Uhl, D. ;
Wagner, P. ;
Waltenberger, W. ;
Walzel, G. ;
Widl, E. ;
Wulz, C. -E. ;
Chekhovsky, V. ;
Dvornikov, O. ;
Emeliantchik, I. ;
Litomin, A. .
JOURNAL OF INSTRUMENTATION, 2010, 5
[6]   Gamma-ray induced radiation damage in large size LSO and LYSO crystal samples [J].
Chen, Jianming ;
Mao, Rihua ;
Zhang, Liyuan ;
Zhu, Ren-Yuan .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) :1319-1326
[7]   Muon decay in orbit spectra for μ-e conversion experiments [J].
Czarnecki, Andrzej ;
Garcia i Tormo, Xavier ;
Marciano, William Joseph .
HYPERFINE INTERACTIONS, 2012, 210 (1-3) :19-23
[8]   Results on damage induced by high-energy protons in LYSO calorimeter crystals [J].
Dissertori, G. ;
Luckey, D. ;
Nessi-Tedaldi, F. ;
Pauss, F. ;
Quittnat, M. ;
Wallny, R. ;
Glaser, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 745 :1-6
[9]   A detailed test of the CsI(Tl) calorimeter for BELLE with photon beams of energy between 20 MeV and 5.4 GeV [J].
Ikeda, H ;
Satpathy, A ;
Ahn, BS ;
Aulchenko, VM ;
Bondar, AE ;
Cheon, BG ;
Chu, TH ;
Fukushima, M ;
Garmash, AY ;
Hayashii, H ;
Jang, HK ;
Kaneyuki, K ;
Kazui, K ;
Kezerashvili, GY ;
Kim, HJ ;
Kremyanskaya, EV ;
Kuzmin, AS ;
Lee, MH ;
Miyabayashi, K ;
Muchnoi, NY ;
Naumenkov, AI ;
Noguchi, S ;
Park, CS ;
Popov, VG ;
Protopopov, IY ;
Pogorelov, YA ;
Romanov, LV ;
Root, NI ;
Sagawa, H ;
Shatilov, DN ;
Sidorov, AV ;
Simonov, EA ;
Shwartz, BA ;
Tamai, K ;
Tsukamoto, T ;
Usov, YV ;
Watanabe, Y ;
Zhilich, VN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 441 (03) :401-426
[10]   Charged Lepton Flavor Violation Experiments [J].
Marciano, William J. ;
Mori, Toshinori ;
Roney, J. Michael .
ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, 2008, 58 :315-341