Assessment of dose exposure and image quality in coronary angiography performed by 640-slice CT: a comparison between adaptive iterative and filtered back-projection algorithm by propensity analysis

被引:42
作者
Di Cesare, Ernesto [1 ]
Gennarelli, Antonio [2 ]
Di Sibio, Alessandra [2 ]
Felli, Valentina [2 ]
Splendiani, Alessandra [2 ]
Gravina, Giovanni Luca [3 ]
Barile, Antonio [2 ]
Masciocchi, Carlo [2 ]
机构
[1] Univ Aquila, Dept Biotechnol & Appl Clin Sci, Div Cardiac Radiol, I-67100 Laquila, Italy
[2] Univ Aquila, Dept Biotechnol & Appl Clin Sci, Div Radiol, I-67100 Laquila, Italy
[3] Univ Aquila, Dept Biotechnol & Appl Clin Sci, Div Radiotherapy, Radiobiol Lab, I-67100 Laquila, Italy
来源
RADIOLOGIA MEDICA | 2014年 / 119卷 / 08期
关键词
Coronary CT angiography; Adaptive-iterative reconstruction; Image noise; Radiation dose; Image quality; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; RADIATION-EXPOSURE; RECONSTRUCTION; REDUCTION;
D O I
10.1007/s11547-014-0382-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study was performed to confirm, by propensity score matching, whether the use of adaptive-iterative dose reduction (AIDR 3D) with a built-in automatic exposure control system provides clinical and dosimetric advantages with respect to the traditional filtered back-projection (FBP) algorithm without automatic exposure modulation. A total of 200 consecutive patients undergoing coronary computed tomography (CT) angiography on a 640-slice CT scanner were studied. A protocol with exposure parameters based on patient body mass index (BMI) and with images reconstructed using FBP (group A) was compared with a protocol with images acquired using tube current decided by an automatic exposure control system and reconstructed using AIDR (group B). Mean effective dose and image quality with both objective and subjective measurements were assessed. Mean effective dose was 23.6 % lower in group B than in group A (2.56 versus 3.34 mSv; p < 0.0001). Noise was significantly lower in group B with consequent higher signal-to-noise (SNR) and contrast-to-noise (CNR) (p < 0.0001) compared with group A. Subjective quality parameters were also significantly higher in group B. Comparative analysis by propensity score matching confirms that AIDR 3D with automatic exposure control is able to reduce significantly the mean radiation dose and improve the image quality compared with traditional FBP without exposure modulation.
引用
收藏
页码:642 / 649
页数:8
相关论文
共 25 条
[1]  
[Anonymous], 2004, EUROPEAN GUIDELINES
[2]  
Austen W G, 1975, Circulation, V51, P5
[3]   Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[4]   Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography [J].
Cademartiri, Filippo ;
La Grutta, Ludovico ;
Runza, Giuseppe ;
Palumbo, Alessandro ;
Maffei, Erica ;
Mollet, Nico R. A. ;
Bartolotta, Tommaso Vincenzo ;
Somers, Pamela ;
Knaapen, Michiel ;
Verheye, Stefan ;
Midiri, Massimo ;
Hamers, Ronald ;
Bruining, Nico .
EUROPEAN RADIOLOGY, 2007, 17 (07) :1842-1849
[5]   Simulated 50 % radiation dose reduction in coronary CT angiography using adaptive iterative dose reduction in three-dimensions (AIDR3D) [J].
Chen, Marcus Y. ;
Steigner, Michael L. ;
Leung, Steve W. ;
Kumamaru, Kanako K. ;
Schultz, Kurt ;
Mather, Richard T. ;
Arai, Andrew E. ;
Rybicki, Frank J. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05) :1167-1175
[6]   Effects of nitroglycerin on the diagnostic accuracy of electrocardiogram-gated coronary computed tomography angiography [J].
Chun, Eun Ju ;
Lee, Whal ;
Choi, Young Hoon ;
Koo, Bon-Kwon ;
Choi, Sang Il ;
Jae, Hwan Jun ;
Kim, Hyo-Cheol ;
So, Young Ho ;
Chung, Jin Wook ;
Park, Jae Hyung .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (01) :86-92
[7]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[8]   Noninvasive Coronary Angiography by 320-Row Computed Tomography With Lower Radiation Exposure and Maintained Diagnostic Accuracy Comparison of Results With Cardiac Catheterization in a Head-to-Head Pilot Investigation [J].
Dewey, Marc ;
Zimmermann, Elke ;
Deissenrieder, Florian ;
Laule, Michael ;
Duebel, Hans-Peter ;
Schlattmann, Peter ;
Knebel, Fabian ;
Rutsch, Wolfgang ;
Hamm, Bernd .
CIRCULATION, 2009, 120 (10) :867-875
[9]   Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radiology (SIRM) [J].
di Cesare, E. ;
Carbone, I. ;
Carriero, A. ;
Centonze, M. ;
De Cobelli, F. ;
De Rosa, R. ;
Di Renzi, P. ;
Esposito, A. ;
Faletti, R. ;
Fattori, R. ;
Francone, M. ;
Giovagnoni, A. ;
La Grutta, L. ;
Ligabue, G. ;
Lovato, L. ;
Marano, R. ;
Midiri, M. ;
Natale, L. ;
Romagnoli, A. ;
Russo, V. ;
Sardanelli, F. ;
Cademartiri, F. .
RADIOLOGIA MEDICA, 2012, 117 (06) :901-938
[10]   Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography [J].
Einstein, Andrew J. ;
Henzlova, Milena J. ;
Rajagopalan, Sanjay .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03) :317-323