Liquid chromatography-mass spectrometry analysis of hydroxylated polycyclic aromatic hydrocarbons, formed in a simulator of the human gastrointestinal tract

被引:27
作者
Van de Wiele, TR
Peru, KM
Verstraete, W
Siciliano, SD
Headley, JV
机构
[1] Natl Water Res Inst Branch, NWRI, Saskatoon, SK S7N 3H5, Canada
[2] State Univ Ghent, Lab Microbial Ecol & Technol, B-9000 Ghent, Belgium
[3] Univ Saskatchewan, Dept Soil Sci, Saskatoon, SK, Canada
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 806卷 / 02期
关键词
polynuclear aromatic hydrocarbons;
D O I
10.1016/j.jchromb.2004.04.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Described is a liquid chromatography-mass spectrometry (LC-MS) procedure for the determination of hydroxylated biotransformation products of polycyclic aromatic hydrocarbons (PAH) in the human gastrointestinal tract. The formation of hydroxylated PAHs was monitored upon incubation of PAHs with colon microbiota from the Simulator of the Human Intestinal Microbial Ecosystem (SHIME). The analytical method consisted of a biomass removal step followed by a solid phase extraction (SPE) step using C18 packed columns to remove non-digested food compounds and microbial metabolites that interfere with the detection of the target compounds. For quantification, 9-hydroxyphenanthrene C-13(6) was used as the internal standard. The detection limits of the hydroxylated PAHs were generally in the range 0.36-14.09 mug l(-1), based on a signal/noise ratio of 3:1. The recovery of hydroxylated PAHs in intestinal suspension was variable ranging from 45 to 107%, with relative standard deviation (R.S.D.) between 5 and 17%. The analytical procedure was used to show the microbial production of I-hydroxypyrene and 7-hydroxybenzo(a)pyrene, metabolites that may give colon incubated PAHs bioactive properties. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 253
页数:9
相关论文
共 27 条
[1]   Susceptibility and exposure biomarkers in people exposed to PAHs from diesel exhaust [J].
Adonis, M ;
Martínez, V ;
Riquelme, R ;
Ancic, P ;
González, G ;
Tapia, R ;
Castro, M ;
Lucas, D ;
Berthou, F ;
Gil, L .
TOXICOLOGY LETTERS, 2003, 144 (01) :3-15
[2]   MULTIMETHOD DETERMINATION OF OCCUPATIONAL EXPOSURE TO POLYCYCLIC AROMATIC-HYDROCARBONS IN AN ALUMINUM PLANT [J].
BECHER, G ;
HAUGEN, A ;
BJORSETH, A .
CARCINOGENESIS, 1984, 5 (05) :647-651
[3]  
BUCKLEY TJ, 1992, BRIT J IND MED, V49, P113
[4]   Study of fungal degradation products of polycyclic aromatic hydrocarbons using gas chromatography with ion trap mass spectrometry detection [J].
Cajthaml, T ;
Möder, M ;
Kacer, P ;
Sasek, V ;
Popp, P .
JOURNAL OF CHROMATOGRAPHY A, 2002, 974 (1-2) :213-222
[5]   Determination of 1-hydroxypyrene in human urine by high-performance liquid chromatography with fluorescence detection using a deuterated internal standard [J].
Chetiyanukornkul, T ;
Toriba, A ;
Kizu, R ;
Makino, T ;
Nakazawa, H ;
Hayakawa, K .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) :107-112
[6]   Biomonitoring of PAH pollution in high-altitude mountain lakes through the analysis of fish bile [J].
Escartín, E ;
Porte, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (03) :406-409
[7]   Quantitative determination of 1-hydroxypyrene in bovine urine samples using high-performance liquid chromatography with fluorescence and mass spectrometric detection [J].
Ferrari, S ;
Mandel, F ;
Berset, JD .
CHEMOSPHERE, 2002, 47 (02) :173-182
[8]   Determination of hydroxy polycyclic aromatic hydrocarbons by liquid chromatography mass spectrometry - Comparison of atmospheric pressure chemical ionization and electrospray [J].
Galceran, MT ;
Moyano, E .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :75-84
[9]  
GALCERAN MT, 1994, J CHROMATOGR A, V683, P4
[10]   Comparison of acute toxicity and genotoxic concentrations of single compounds and waste elutriates using the Microtox/Mutatox test system [J].
Hauser, B ;
Schrader, G ;
Bahadir, M .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 1997, 38 (03) :227-231