A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments

被引:76
作者
Huelsmann, M. [1 ]
Donnermeyer, D. [2 ]
Schaefer, E. [3 ]
机构
[1] UMG, Dept Prevent Dent Periodontol & Cariol, Robert Koch Str 40, D-37075 Gottingen, Germany
[2] Westphalian Wilhelms Univ, Dept Periodontol & Operat, Munster, Germany
[3] Westphalian Wilhelms Univ, Cent Interdisciplinary Ambulance, Munster, Germany
关键词
cyclic fracture; dynamic fatigue tests; environmental temperature; nickel-titanium instruments; static fatigue tests; NICKEL-TITANIUM ROTARY; PROTAPER UNIVERSAL INSTRUMENTS; WAVEONE GOLD; GLIDE PATH; ROTATIONAL SPEED; RECIPROC BLUE; SODIUM-HYPOCHLORITE; M-WIRE; MECHANICAL-PROPERTIES; MOVEMENT KINEMATICS;
D O I
10.1111/iej.13182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The endodontic literature contains a plethora of studies on static and dynamic cyclic fatigue resistance tests performed on a large array of rotary or reciprocating nickel-titanium endodontic instruments. It was the aim of this review to summarize the currently available evidence to point out the different outcomes from static versus dynamic tests and to assess whether cyclic fatigue tests provide useful data and information for clinical practice. An electronic literature research in the database PubMed was performed using appropriate search terms, and the titles and abstract were screened for relevance. Language was restricted to English. The review reveals marked differences between the results obtained in static and dynamic tests, and also, the results for the same instruments assessed either under static or dynamic experimental conditions are widely inconsistent. Between the lowest and the highest value for one and the same pathfinding instrument was a factor of about 123 when cyclic fatigue was assessed either under static or dynamic experimental conditions. Moreover, standard deviations of up to 30% have been reported. Environmental temperature has a 500% impact on the lifetime of instruments. In conclusion, fatigue resistance tests conducted under room temperature should be regarded as having little meaning and the scientific and clinical benefits of fatigue resistance tests are very limited. These data should be provided by the manufacturer of the instruments.
引用
收藏
页码:1427 / 1445
页数:19
相关论文
共 119 条
[1]   Comparison of Cyclic Fatigue Resistance of WaveOne and WaveOne Gold Small, Primary, and Large Instruments [J].
Achguzel, Mehmet ;
Capar, Ismail Davut .
JOURNAL OF ENDODONTICS, 2017, 43 (04) :623-627
[2]   Effects of Sodium Hypochlorite Concentration and Temperature on the Cyclic Fatigue Resistance of Heat-treated Nickel-titanium Rotary Instruments [J].
Alfawaz, Hussam ;
Alqedairi, Abdullah ;
Alsharekh, Hala ;
Almuzaini, Eman ;
Alzahrani, Shand ;
Jamleh, Ahmed .
JOURNAL OF ENDODONTICS, 2018, 44 (10) :1563-1566
[3]   Cyclic fatigue resistance of a novel rotary file manufactured using controlled memory Ni-Ti technology compared to a file made from M-wire file [J].
AlShwaimi, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (01) :112-117
[4]   Evaluation of single-use rotary nickel-titanium instruments [J].
Arens, FC ;
Hoen, MM ;
Steiman, HR ;
Dietz, GC .
JOURNAL OF ENDODONTICS, 2003, 29 (10) :664-666
[5]   Variable impact by ambient temperature on fatigue resistance of heat-treated nickel titanium instruments [J].
Arias, Ana ;
Hejlawy, Samer ;
Murphy, Sarah ;
de la Macorra, Jose C. ;
Govindjee, Sanjay ;
Peters, Ove A. .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (03) :1101-1108
[6]   Correlation between Temperature-dependent Fatigue Resistance and Differential Scanning Calorimetry Analysis for 2 Contemporary Rotary Instruments [J].
Arias, Ana ;
Macorra, Jose C. ;
Govindjee, Sanjay ;
Peters, Ove A. .
JOURNAL OF ENDODONTICS, 2018, 44 (04) :630-634
[7]   Real-time dynamic torque values and axial forces during preparation of straight root canals using three different endodontic motors and hand preparation [J].
Buerklein, S. ;
Stueber, J. P. ;
Schaefer, E. .
INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (01) :94-104
[8]   Effect of irrigation on surface roughness and fatigue resistance of controlled memory wire nickel-titanium instruments [J].
Cai, J. -J. ;
Tang, X. -N. ;
Ge, J. -Y. .
INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (07) :718-724
[9]   Comparison of the Cyclic Fatigue Resistance of 5 Different Rotary Pathfinding Instruments Made of Conventional Nickel-Titanium Wire, M-wire, and Controlled Memory Wire [J].
Capar, Ismail Davut ;
Kaval, Mehmet Emin ;
Ertas, Huseyin ;
Sen, Bilge Hakan .
JOURNAL OF ENDODONTICS, 2015, 41 (04) :535-538
[10]   Comparison of Cyclic Fatigue Resistance of Nickel-Titanium Coronal Flaring Instruments [J].
Capar, Ismail Davut ;
Ertas, Huseyin ;
Arslan, Hakan .
JOURNAL OF ENDODONTICS, 2014, 40 (08) :1182-1185