Variation of neutron detection characteristics with dimension of BC501A neutron detector

被引:61
作者
Banerjee, K. [1 ]
Ghosh, T. K.
Kundu, S.
Rana, T. K.
Bhattacharya, C.
Meenaa, J. K.
Mukherjee, G.
Mali, P.
Gupta, D.
Mukhopadhyay, S.
Pandit, D.
Banerjee, S. R.
Bhattacharya, S.
Bandyopadhyay, T. [1 ]
Chatterjee, S. [1 ]
机构
[1] Bhabha Atom Res Ctr, Ctr Variable Energy Cyclotron, HS&E Grp, Kolkata 700064, India
关键词
Liquid scintillator BC501A; Efficiency measurement; Simulation; PULSE-SHAPE DISCRIMINATION; N-GAMMA DISCRIMINATION; LIQUID SCINTILLATION DETECTORS; DETECTION EFFICIENCY; NE213;
D O I
10.1016/j.nima.2009.07.034
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A systematic study of the variation of neutron detection characteristics (efficiency, pulse shape discrimination) and the intrinsic time resolution with the active volume of the detector has been carried out with liquid scintillator (BC501A)-based neutron detectors of various dimensions designed and fabricated for this purpose. Energy-dependent neutron detection efficiency has been measured using associated particle technique and its dependence on detector dimension has been studied. The measured efficiencies have been compared with those obtained from GEANT4 simulations. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:440 / 446
页数:7
相关论文
共 27 条
[11]  
DICKENS JK, 1988, ORNL6436
[12]  
FASSO A, 2003, COMP HIGH EN NUCL PH
[13]  
Ferrari A, 2005, CERN-2005-10, INFN/TC_05/11, SLAC-R-773
[14]   Time of flight (TOF) spectrometer for accurate measurement of mass and angular distribution of fission fragments in heavy ion induced fission reactions [J].
Ghosh, TK ;
Pal, S ;
Sinha, T ;
Chattopadhyay, S ;
Golda, KS ;
Bhattacharya, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (2-3) :285-294
[15]   RELATIVE NEUTRON DETECTOR EFFICIENCY AND RESPONSE FUNCTION MEASUREMENTS WITH A CF-252 NEUTRON SOURCE [J].
GUL, K ;
NAQVI, AA ;
ALJUWAIR, HA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 278 (02) :470-476
[16]   Comparison of two liquid scintillators used for neutron detection [J].
Horváth, A ;
Ieki, K ;
Iwata, Y ;
Kruse, JJ ;
Seres, Z ;
Wang, J ;
Weiner, J ;
Zecher, PD ;
Galonsky, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 440 (01) :241-244
[17]   EVALUATION OF PULSE-SHAPE DISCRIMINATION CAPABILITIES OF NE228A+ RELATIVE TO NE213+ [J].
HOWE, RE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 190 (02) :309-311
[18]   PULSE SHAPE DISCRIMINATION - AN INVESTIGATION OF N-GAMMA DISCRIMINATION WITH RESPECT TO SIZE OF LIQUID SCINTILLATOR [J].
KALYNA, J ;
TAYLOR, IJ .
NUCLEAR INSTRUMENTS & METHODS, 1970, 88 (02) :277-+
[19]   Neutron and photon spectrometry with liquid scintillation detectors in mixed fields [J].
Klein, H ;
Neumann, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2) :132-142
[20]  
KLEIN H, POS