Numerical investigation of pilots' micro-environment in an airliner cockpit

被引:10
作者
Yan, Yihuan [1 ]
Li, Xueren [1 ,2 ]
Tao, Yao [1 ]
Fang, Xiang [1 ]
Yan, Ping [1 ]
Tu, Jiyuan [2 ]
机构
[1] Shanghai Univ Engn Sci, Sch Air Transportat Flying, Shanghai 201620, Peoples R China
[2] RMIT Univ, Sch Engn, POB 71, Bundoora, Vic 3083, Australia
关键词
Commercial airliner cockpit; Micro-environment; CFD; Thermal plume; Cockpit air quality; Contaminants removal effectiveness; K-EPSILON MODELS; AIRCRAFT CABIN; AIR; PARTICLES; HEALTH; HEAT;
D O I
10.1016/j.buildenv.2022.109043
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Airflow in the cockpits of commercial airliners could be substantially different and more complex than it in passenger cabins, while simply referring to the standard of passenger cabin may not effectively achieve optimum ventilation or ensure a comfortable working environment for pilots. This study numerically investigated the ventilated Boeing 737 cockpit by analysing its airflow and thermal distribution inside, especially in pilots' microenvironments, under various in-flight conditions (number of personalised jet-inlets, window heat exchange, etc.). Gaseous contaminant CO2 released from pilots was analysed in relation to its concentration distribution and potential lock-up phenomena in pilots' micro-environments, followed by quantitative analysis of pilots' thermal comfort and air quality. The outcomes demonstrated that the window heat exchange had significant impacts on pilots' thermal sensation and could induce severe thermal stratification around pilots' head level. The most effective CO2 removal rate was achieved by initiating windshield inlets in combination of the side diffusers. Further adding personal gaspers did not significantly alleviate the CO2 concentration in pilots' microenvironment but may potentially compromise their thermal comfort. Also, the overwhelming numbers of personalised inlets could hardly provide superior ventilation performance or ensure consistent air quality and could be impractical to use sometimes. It is suggested that future optimisation of the environmental control system could rely more on the global airflow circulations induced by larger or wider diffusers rather than the local complex jet flows from high number of personal gaspers.
引用
收藏
页数:13
相关论文
共 37 条
[1]   Airplane pilot flight performance on 21 maneuvers in a flight simulator under varying carbon dioxide concentrations [J].
Allen, Joseph G. ;
MacNaughton, Piers ;
Cedeno-Laurent, Jose Guillermo ;
Cao, Xiaodong ;
Flanigan, Skye ;
Vallarino, Jose ;
Rueda, Francisco ;
Donnelly-McLay, Deborah ;
Spengler, John D. .
JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2019, 29 (04) :457-468
[2]   Numerical investigation of indoor thermal comfort and air quality for a multi-purpose hall with various shading and glazing ratios [J].
Amini, Reza ;
Ghaffarianhoseini, Amirhosein ;
Ghaffarianhoseini, Ali ;
Berardi, Umberto .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 22
[3]  
[Anonymous], 2011, ASHRAE HDB HVAC APPL
[4]  
[Anonymous], 2017, ASHRAE STANDARD 55 2
[5]  
ANSYSInc, 2021, ANSYS Fluent 2020 R1 User's Guide
[6]  
ASHRAE, 1997, 1291997 ASHRAE
[7]  
ASHRAE, 2016, AIR QUAL COMM AIRCR
[8]   Experimental analysis of the air velocity and contaminant dispersion of human exhalation flows [J].
Berlanga, F. A. ;
Olmedo, I. ;
Ruiz de Adana, M. .
INDOOR AIR, 2017, 27 (04) :803-815
[9]   COMPARISON OF DIFFERENT K-EPSILON MODELS FOR INDOOR AIR-FLOW COMPUTATIONS [J].
CHEN, Q .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1995, 28 (03) :353-369
[10]   Thermal comfort models: A review and numerical investigation [J].
Cheng, Yuanda ;
Niu, Jianlei ;
Gao, Naiping .
BUILDING AND ENVIRONMENT, 2012, 47 :13-22