Foundations of retention in partition chromatography

被引:81
作者
Poole, Colin F. [1 ]
Poole, Salwa K. [1 ]
机构
[1] Wayne State Univ, Dept Chem, Detroit, MI 48202 USA
关键词
Gas-liquid chromatography; Liquid chromatography; Supercritical fluid chromatography; Micellar electrokinetic chromatography; Capillary electrochromatography; Retention mechanisms; Retention factor; Specific retention volume; Retenion index; Column hold-up volume; Interfacial adsorption; Isotherms; Programmed separations; PHASE LIQUID-CHROMATOGRAPHY; SUPERCRITICAL-FLUID CHROMATOGRAPHY; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PROGRAMMED GAS-CHROMATOGRAPHY; HOLD-UP TIME; EXCESS ADSORPTION-ISOTHERMS; SILICA STATIONARY-PHASE; HYDROPHOBIC-SUBTRACTION MODEL; PERFORMANCE GRADIENT ELUTION; SOLUTE-SOLVENT INTERACTIONS;
D O I
10.1016/j.chroma.2008.10.092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The connection between the observable output in column chromatography (retention time, retention volume, retention factor, separation factor, etc.) and system properties (hold-up volume, pressure, temperature, isotherm behavior, etc.) is discussed from a practical and mechanistic perspective for gas-liquid chromatography, reversed-phase liquid chromatography, supercritical fluid chromatography, micellar electrokinetic chromatography, and capillary electrochromatography. The unifying feature of these techniques is that retention can be described by a partition model, although not always exclusively. When over simplistic system models are used to explain variation in retention parameters they frequently mask the true reasons for poor repeatability and difficulties in transfer between system. Methods employing relative retention afford higher precision but may contain residual uncorrected errors. For those systems with several separate mechanisms contributing to retention the effective retention parameters can no longer be interpreted by simple partition models. The broadly based and practically focused material in this article affords an illustration of the often complicated relationship between system properties and retention, and the dangers that lurk in simplified retention models if the validity of their underlining approximations is not appropriate for the system under study. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1530 / 1550
页数:21
相关论文
共 298 条
[31]   Influence of the unpacked section on the chromatographic performance of duplex strong anion-exchange columns in capillary electrochromatography [J].
Byrne, CD ;
Smith, NW ;
Dearie, HS ;
Moffatt, F ;
Wren, SAC ;
Evans, KP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :169-177
[32]  
Cahill JE, 1998, HRC-J HIGH RES CHROM, V21, P531
[33]   Retention index systems:: alternatives to the n-alkanes as calibration standards [J].
Castello, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :51-64
[34]   THEORETICAL CALCULATION OF GAS HOLD-UP TIME IN CAPILLARY GAS-CHROMATOGRAPHY - INFLUENCE OF COLUMN, INSTRUMENT PARAMETERS AND ANALYSIS CONDITIONS AND COMPARISON OF DIFFERENT METHODS OF DEAD-TIME DETERMINATION [J].
CASTELLO, G ;
VEZZANI, S ;
MORETTI, P .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) :95-106
[35]   Effect of temperature on pH measurements and acid-base equilibria in methanol-water mixtures [J].
Castells, CB ;
Ràfols, C ;
Rosés, M ;
Bosch, E .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) :41-53
[36]   Determination of gas-liquid partition coefficients by gas chromatography [J].
Castells, RC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) :223-231
[37]   Interpretation of the excess adsorption isotherms of organic eluent components on the surface of reversed-phase phenyl modified adsorbents [J].
Chan, F ;
Yeung, LS ;
LoBrutto, R ;
Kazakevich, Y .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) :158-165
[38]   Influence of moderate Joule heating on electroosmotic flow velocity, retention, and efficiency in capillary electrochromatography [J].
Chen, GF ;
Tallarek, U ;
Seidel-Morgenstern, A ;
Zhang, YK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1044 (1-2) :287-294
[39]   Novel approach for the prediction of retention times in operating parameter programmed gas-liquid chromatography with capillary columns [J].
Chen, JP ;
Zhang, LF ;
Tian, YZ ;
Wang, LX .
JOURNAL OF CHROMATOGRAPHY A, 1998, 795 (02) :305-317
[40]  
Chen MH, 1997, J CHROMATOGR A, V788, P51