Foundations of retention in partition chromatography

被引:81
作者
Poole, Colin F. [1 ]
Poole, Salwa K. [1 ]
机构
[1] Wayne State Univ, Dept Chem, Detroit, MI 48202 USA
关键词
Gas-liquid chromatography; Liquid chromatography; Supercritical fluid chromatography; Micellar electrokinetic chromatography; Capillary electrochromatography; Retention mechanisms; Retention factor; Specific retention volume; Retenion index; Column hold-up volume; Interfacial adsorption; Isotherms; Programmed separations; PHASE LIQUID-CHROMATOGRAPHY; SUPERCRITICAL-FLUID CHROMATOGRAPHY; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; PROGRAMMED GAS-CHROMATOGRAPHY; HOLD-UP TIME; EXCESS ADSORPTION-ISOTHERMS; SILICA STATIONARY-PHASE; HYDROPHOBIC-SUBTRACTION MODEL; PERFORMANCE GRADIENT ELUTION; SOLUTE-SOLVENT INTERACTIONS;
D O I
10.1016/j.chroma.2008.10.092
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The connection between the observable output in column chromatography (retention time, retention volume, retention factor, separation factor, etc.) and system properties (hold-up volume, pressure, temperature, isotherm behavior, etc.) is discussed from a practical and mechanistic perspective for gas-liquid chromatography, reversed-phase liquid chromatography, supercritical fluid chromatography, micellar electrokinetic chromatography, and capillary electrochromatography. The unifying feature of these techniques is that retention can be described by a partition model, although not always exclusively. When over simplistic system models are used to explain variation in retention parameters they frequently mask the true reasons for poor repeatability and difficulties in transfer between system. Methods employing relative retention afford higher precision but may contain residual uncorrected errors. For those systems with several separate mechanisms contributing to retention the effective retention parameters can no longer be interpreted by simple partition models. The broadly based and practically focused material in this article affords an illustration of the often complicated relationship between system properties and retention, and the dangers that lurk in simplified retention models if the validity of their underlining approximations is not appropriate for the system under study. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1530 / 1550
页数:21
相关论文
共 298 条
[1]  
Abdel-Rehim M, 1999, J MICROCOLUMN SEP, V11, P63, DOI 10.1002/(SICI)1520-667X(1999)11:1<63::AID-MCS8>3.0.CO
[2]  
2-X
[3]   COMPARISON OF UNCORRECTED RETENTION DATA ON A CAPILLARY AND A PACKED HEXADECANE COLUMN WITH CORRECTED RETENTION DATA ON A PACKED SQUALANE COLUMN [J].
ABRAHAM, MH ;
ANDONIANHAFTVEN, J ;
DU, CM ;
OSEIOWUSU, JP ;
SAKELLARIOU, P ;
SHUELY, WJ ;
POOLE, CF ;
POOLE, SK .
JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) :125-134
[4]   Classification of stationary phases and other materials by gas chromatography [J].
Abraham, MH ;
Poole, CF ;
Poole, SK .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :79-114
[5]   COLUMN DEAD VOLUME IN LIQUID-CHROMATOGRAPHY [J].
ALHEDAI, A ;
MARTIRE, DE ;
SCOTT, RPW .
ANALYST, 1989, 114 (08) :869-875
[6]  
Arutyunov YI, 2005, RUSS J PHYS CHEM+, V79, P967
[7]   Development of a database of gas chromatographic retention properties of organic compounds [J].
Babushok, V. I. ;
Linstrom, P. J. ;
Reed, J. J. ;
Zenkevich, I. G. ;
Brown, R. L. ;
Mallard, W. G. ;
Stein, S. E. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1157 (1-2) :414-421
[8]  
Bartle K.D., 2001, CAPILLARY ELECTROCHR
[9]   Theory of capillary electrochromatograpy [J].
Bartle, KD ;
Myers, P .
JOURNAL OF CHROMATOGRAPHY A, 2001, 916 (1-2) :3-23
[10]   Inverse gas chromatography as a tool for investigation of nanomaterials [J].
Batko, Kalina ;
Voelkel, Adam .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2007, 315 (02) :768-771